background image

 

Page | 1 
 

PRODUCT GUIDE 

Wärtsilä 31SG 

Содержание 31SG

Страница 1: ...Page 1 PRODUCT GUIDE W rtsil 31SG...

Страница 2: ...REGULAR IMPROVEMENTS MODIFICATIONS AND CHANGES CONSEQUENTLY THE PUBLISHER AND COPYRIGHT OWNER OF THIS PUBLICATION CAN NOT ACCEPT ANY RESPONSIBILITY OR LIABILITY FOR ANY EVENTUAL ERRORS OR OMISSIONS IN...

Страница 3: ...specific instructions for planning the installation are always delivered Any data and information herein is subject to revision without notice Issue Published Updates 9 2019 n a First Version 9 2019...

Страница 4: ...Page 4 This page intentionally left blank...

Страница 5: ...rtsil 14V31SG 32 3 6 W rtsil 16V31SG 35 4 Description of the Engine 38 4 1 Definitions 38 4 2 Main components and systems 38 4 3 Time between Inspection or Overhaul Expected Life Time 42 4 4 Engine st...

Страница 6: ...engine exhaust components 99 13 2 Marine exhaust emissions legislation 99 13 3 Methods to reduce exhaust emissions 99 14 Automation System 100 14 1 Technical data and system overview 100 14 2 Function...

Страница 7: ...ls 121 18 4 Required deck area for service work 121 19 Transport Dimensions and Weights 125 19 1 Lifting of generating sets 125 19 2 Engine components 126 20 Product Guide Attachments 128 21 ANNEX 130...

Страница 8: ...Page 8 This page intentionally left blank...

Страница 9: ...1 Maximum continuous output Table 1 1 Rating table for W rtsil 31SG The mean effective pressure Pe can be calculated as follows where Pe mean effective pressure bar P output per cylinder kW n engine...

Страница 10: ...etric pressure 100 kPa air temperature 25 C relative humidity 30 charge air coolant temperature 25 C Correction factors for the fuel oil consumption in other ambient conditions are given in standard I...

Страница 11: ...6 W 8V31SG 6087 6196 3560 1650 1650 877 986 300 500 500 W 10V31SG 6726 6836 4200 1650 1650 877 986 300 500 500 Engine H1 H1 H2 H3 H4 W1 W1 W2 W3 W4 W5 W5 Weight Engine Weight liquids W 8V31SG 3205 320...

Страница 12: ...8730 5480 2000 2000 1000 1250 300 908 908 W 16V31SG 9120 9370 9120 2000 2000 1000 1250 300 908 908 Engine H1 H1 H2 H3 H4 W1 W2 W3 W4 W5 Weight Engine Weight liquids W 12V31SG 2926 2926 4633 1496 650...

Страница 13: ...t without liquids damper and flywheel as a rule of thumb add 60kg per cylinder on top of 8 and or 10V engine weight or add 50kg per cylinder for 12 14 and 16V engines for additional gas components wei...

Страница 14: ...Page 14 This page intentionally left blank...

Страница 15: ...acity Controlled load increase is essential for highly supercharged engines as the turbocharger needs time to accelerate before it can deliver the required amount of air A slower loading ramp than the...

Страница 16: ...oading rate Engine load of MCR Nominal loading s Fast loading MN70 s Fast loading MN80 s Emergency Hybrid operation only s 0 0 0 0 0 100 300 90 70 20 Fig 2 1 Normal Loading rate constant speed engines...

Страница 17: ...he propulsion control The emergency curve is close to the maximum capability of the system and it shall not be used as the normal limit for the engine In dynamic positioning applications loading ramps...

Страница 18: ...hich has been operated at above 30 load within the last 30 minutes If higher load step capability is required then the dimensioning of the Energy Storage System needs to be applied Following Hybrid lo...

Страница 19: ...ive low load operation should not exceed the recommended values given in the chart and table The time is reset after a cleaning run at minimum 70 load for a minimum of 1 hour If recommended time limit...

Страница 20: ...d generator Maximum 10 minutes if the engine is to be stopped after the idling 3 5 minutes idling before stop is recommended Maximum 8 hours if the engine is to be loaded after the idling NOTE Operati...

Страница 21: ...Page 21 This page intentionally left blank...

Страница 22: ...n the respective chapter 3 1 1 Engine driven pumps The fuel consumption stated in the technical data tables is with engine driven pumps The increase in fuel consumption with engine driven pumps is giv...

Страница 23: ...r turbocharger at 100 load TE 517 C 344 346 300 346 Temperature after turbocharger at 85 load TE 517 C 360 362 350 362 Temperature after turbocharger at 75 load TE 517 C 375 377 350 377 Temperature af...

Страница 24: ...Oil volume in turning device l 9 0 11 0 9 0 11 0 9 0 11 0 9 0 11 0 Cooling water system HT cooling water system Pressure at engine after pump nom PT 401 kPa 358 static 358 static 358 static 358 stati...

Страница 25: ...ng to ISO 15550 except for LT water temperature which is corresponding to charge air receiver temperature 55 C in gas operation with engine driven water and lubricating oil pumps Tolerance for cooling...

Страница 26: ...4 6 4 5 4 6 Temperature after turbocharger at 100 load TE 517 C 344 346 344 346 Temperature after turbocharger at 85 load TE 517 C 360 362 360 362 Temperature after turbocharger at 75 load TE 517 C 3...

Страница 27: ...se ventilation backpressure max kPa 0 1 0 1 0 1 0 1 Oil volume in turning device l 9 0 11 0 9 0 11 0 9 0 11 0 9 0 11 0 Cooling water system HT cooling water system Pressure at engine after pump nom PT...

Страница 28: ...conditions according to ISO 15550 except for LT water temperature which is corresponding to charge air receiver temperature 55 C in gas operation with engine driven water and lubricating oil pumps To...

Страница 29: ...turbocharger at 100 load TE 517 C 344 346 344 346 Temperature after turbocharger at 85 load TE 517 C 360 362 360 362 Temperature after turbocharger at 75 load TE 517 C 375 377 375 377 Temperature aft...

Страница 30: ...Oil volume in turning device l 9 0 11 0 9 0 11 0 9 0 11 0 9 0 11 0 Cooling water system HT cooling water system Pressure at engine after pump nom PT 401 kPa 363 static 363 static 363 static 363 stati...

Страница 31: ...ng to ISO 15550 except for LT water temperature which is corresponding to charge air receiver temperature 55 C in gas operation with engine driven water and lubricating oil pumps Tolerance for cooling...

Страница 32: ...ter turbocharger at 100 load TE 517 C 344 346 344 346 Temperature after turbocharger at 85 load TE 517 C 360 362 360 362 Temperature after turbocharger at 75 load TE 517 C 375 377 375 377 Temperature...

Страница 33: ...il volume in turning device l 9 0 11 0 9 0 11 0 9 0 11 0 9 0 11 0 Cooling water system HT cooling water system Pressure at engine after pump nom PT 401 kPa 398 static 398 static 398 static 398 static...

Страница 34: ...ng to ISO 15550 except for LT water temperature which is corresponding to charge air receiver temperature 55 C in gas operation with engine driven water and lubricating oil pumps Tolerance for cooling...

Страница 35: ...ter turbocharger at 100 load TE 517 C 344 346 344 346 Temperature after turbocharger at 85 load TE 517 C 360 362 360 362 Temperature after turbocharger at 75 load TE 517 C 375 377 375 377 Temperature...

Страница 36: ...volume in turning device l 9 0 11 0 9 0 11 0 9 0 11 0 9 0 11 0 Cooling water system HT cooling water system Pressure at engine after pump nom PT 401 kPa 373 static 373 static 373 static 373 static Pr...

Страница 37: ...ng to ISO 15550 except for LT water temperature which is corresponding to charge air receiver temperature 55 C in gas operation with engine driven water and lubricating oil pumps Tolerance for cooling...

Страница 38: ...screws at the lower guiding provide a very rigid crankshaft bearing assembly A hydraulic jack supported in the oil sump offers the possibility to lower and lift the main bearing caps e g when inspect...

Страница 39: ...luence on the bearing function A wireless system for real time temperature monitoring of connecting rod big end bearings BEB monitoring system is as standard 4 2 5 Cylinder liner The cylinder liners a...

Страница 40: ...st of the components in the valve mechanism 4 2 10 Camshaft drive The camshafts are driven by the crankshaft through a gear train 4 2 11 Turbocharging and charge air cooling The selected 2 stage turbo...

Страница 41: ...w pressure 2 stage charge air cooler The LT water is cooling the lubricating oil cooler the second stage of the low pressure 2 stage charge air cooler and the high pressure 1 stage charge air cooler F...

Страница 42: ...s less than 75 Based on the fuel quality intermediate mechanical cleaning might be necessary Component Time between inspection or overhaul h Expected lifetime Gas Operation Gas Operation Piston 32000...

Страница 43: ...Page 43 This page intentionally left blank...

Страница 44: ...ollowing aspects shall be taken into consideration Pockets shall be avoided When not possible drain plugs and air vents shall be installed Vent pipes shall be continuously rising Flanged connections s...

Страница 45: ...high in terms of their effect on pressure drop In longer supply lines it is often necessary to restrict velocities to 15 m s to limit the pressure drop Pipeline sizing on pressure drop As a rule of th...

Страница 46: ...ferent classes DNV GL or groups ABS depending on pressure temperature and media The pipe class can determine Type of connections to be used Heat treatment Welding procedure Test method Systems with hi...

Страница 47: ...ed to be clean before lifting it onboard for installation During the construction time uncompleted piping systems shall be maintained clean Open pipe ends should be temporarily closed Possible debris...

Страница 48: ...be approved in all work phases after completed pickling 5 8 Flexible pipe connections All external pipes must be precisely aligned to the fitting or the flange of the engine to minimize causing exter...

Страница 49: ...Page 49 Fig 5 1 Flexible hoses...

Страница 50: ...ndation The first support should be located as close as possible to the flexible connection Next support should be 0 3 0 5 m from the first support First three supports closest to the engine or genera...

Страница 51: ...Page 51 Fig 5 3 Flange supports of flexible pipe connections 4V60L0796 Fig 5 4 Pipe clamp for fixed support 4V61H0842...

Страница 52: ...Page 52 This page intentionally left blank...

Страница 53: ...e EN 16726 2015 standard shall be used Additionally W rtsil has developed an MN calculator 2 Hydrogen content higher than 3 volume has to be considered project specifically 3 In the specified operatin...

Страница 54: ...es are solenoid operated and electronically controlled whereas pre chamber is hydro mechanically controlled with sparkplug 6 3 Fuel gas system 6 3 1 External fuel gas system 6 3 1 1 Fuel gas system wi...

Страница 55: ...s system with enclosed GVU Fig 6 2 Example of fuel gas system with enclosed GVU DAAF077105B System components Supplier 01 Gas detector 02 Gas double wall system ventilation fan 10N05 Gas valve unit 10...

Страница 56: ...lose to the tank connection space The ventilation air is taken from both inlets and lead through the annular space of the double wall pipe to the GVU room or to the enclosure of the gas valve unit Fro...

Страница 57: ...upply to the engine on request The solenoid operated venting valve in the double block and bleed function will relief the pressure trapped between the block valves after closing of the block valves Th...

Страница 58: ...Page 58 Fig 6 4 Gas valve unit reference P I diagram DAAF051037D...

Страница 59: ...Page 59 Fig 6 5 Main dimensions of the enclosed GVU DAAF060741A Fig 6 6 Main dimensions of the open GVU DAAW010186A...

Страница 60: ...Page 60 Fig 6 7 Gas valve unit P I diagram open type DAAF085795A...

Страница 61: ...nition Alternatively to ventilating outside into the atmosphere other means of disposal e g a suitable furnace can also be considered However this kind of arrangement has to be accepted by classificat...

Страница 62: ...indicate when the crankcase have been flushed from toxic gases 3 Crankcase size 0 9 m3 crank v engine 6 3 1 8 Gas feed pressure The required fuel gas feed pressure depends on the expected minimum low...

Страница 63: ...of deposit formation preignition and knocking while too low ash content can lead to increased exhaust valve valve seat wear Low ash lubricating oils to be used have typically sulphated ash content of...

Страница 64: ...Page 64 Fig 7 2 Lubricating oil system single engine wet sump DAAF301501B...

Страница 65: ...Page 65 Fig 7 3 Lubricating oil system Gas multiple engines wet sump DAAF301500A...

Страница 66: ...long stop must be taken into account when dimensioning the electric motor Separator preheater 2E02 The preheater is to be dimensioned according to the feed pump capacity and the temperature in the sys...

Страница 67: ...stated in chapter Technical data The pipe connection between the engine oil sump and the system oil tank must be flexible to prevent damages due to thermal expansion The return pipes from the engine o...

Страница 68: ...e The suction strainer and the suction pipe must be amply dimensioned to minimize pressure losses The suction strainer should always be provided with alarm for high differential pressure Design data F...

Страница 69: ...acity see Technical data Design pressure max 0 8 MPa 8 bar Design temperature max 100 C Lubricating oil viscosity SAE 40 Viscosity for dimensioning the electric 500 mm2 s cSt motor 7 3 Crankcase venti...

Страница 70: ...f the piping and equipment built on the engine is not required and flushing oil shall not be pumped through the engine oil system which is flushed and clean from the factory It is however acceptable t...

Страница 71: ...arate flushing oil which has an ideal viscosity in ambient temperature 7 4 3 2 Flushing with engine oil The ideal is to use engine oil for flushing This requires however that the separator unit is in...

Страница 72: ...Page 72 This page intentionally left blank...

Страница 73: ...ification Design pressure 1 MPa 10 bar Nominal pressure 0 7 MPa 7 bar Dew point temperature 3 C Max oil content 1 mg m3 Max particle size 3 m 8 2 External compressed air system The design of the start...

Страница 74: ...nding on the operation conditions of the installation an oil and water separator may be needed in the pipe between the air vessel and the engine 8 2 3 Starting air vessel 3T01 The starting air vessels...

Страница 75: ...arting air vessel volume m3 pE normal barometric pressure NTP condition 0 1 MPa VE air consumption per start Nm3 See Technical data n required number of starts according to the classification society...

Страница 76: ...dosage and further instructions 9 1 2 Glycol Use of glycol in the cooling water is not recommended unless it is absolutely necessary Glycol raises the charge air temperature which may require de ratin...

Страница 77: ...Page 77 Fig 9 1 Example diagram for multiple main engines DAAF301505A...

Страница 78: ...e combustion air can be below zero degrees Celsius after the compressor stage it cools down the cooling water and the engine instead of releasing heat to the cooling water in the charge air cooler If...

Страница 79: ...perature control of the LT water by increasing the seawater temperature 9 2 2 Stand by circulation pumps 4P03 4P05 Stand by pumps should be of centrifugal type and electrically driven Required capacit...

Страница 80: ...w to the fresh water cooler must be calculated case by case based on how the circuit is designed In case the fresh water central cooler is used for combined LT and HT water flows in a parallel system...

Страница 81: ...ufficient static pressure for the circulating pumps Design data Volume min 10 of the total system volume Concerning the water volume in the engine see chapter Technical data The expansion tank should...

Страница 82: ...mbination of both In all cases a separate circulating pump must be used It is common to use the heat from running auxiliary engines for preheating of main engines In installations with several main en...

Страница 83: ...it can be supplied The unit comprises Electric or steam heaters Circulating pump Control cabinet for heaters and pump Set of thermometers Non return valve Safety valve 9 2 13 Throttles Throttles orifi...

Страница 84: ...ir exchanges hour has to be fulfilled is then calculated using the formula where qv air flow m s total heat emission to be evacuated kW air density 1 13 kg m c specific heat capacity of the ventilatio...

Страница 85: ...tion air is taken from the engine room through a filter on the turbocharger This reduces the risk for too low temperatures and contamination of the combustion air It is important that the combustion a...

Страница 86: ...flap to take the air from the engine room or from outside depending on engine load and air temperature For very cold conditions arctic setup is to be used The combustion air fan is stopped during star...

Страница 87: ...Page 87 This page intentionally left blank...

Страница 88: ...10V31 DAAF343596A Fig 11 2 Exhaust pipe connections W12V W16V31 DAAF343596A NOTE Pipe Connection 501 Exhaust Gas Outlet DIN86044 PN 6 Engine TC Location Free end Driving end W 8V31SG 0 45 90 0 45 90 W...

Страница 89: ...pipe into open air Backpressure thermal expansion and supporting are some of the decisive design factors Flexible bellows must be installed directly on the turbocharger outlet to compensate for therma...

Страница 90: ...will be safely directed through predefined routes The following guidelines should be observed when designing the external exhaust system The piping and all other components in the exhaust system shoul...

Страница 91: ...xhaust system Outlets are to discharge to a safe place remote from any source of ignition The number and location of explosion relief devices shall be such that the pressure rise caused by a possible...

Страница 92: ...s very important that the exhaust pipe is properly fixed to a support that is rigid in all directions directly after the bellows on the turbocharger There should be a fixing point on both sides of the...

Страница 93: ...on the engine in order to keep the exhaust gas temperature and backpressure into SCR unit working range The exhaust gas piping must be straight at least 3 5 meters in front of the SCR unit If both an...

Страница 94: ...d to cover the whole frequency spectrum 11 2 10 2 Silencer system comparison With a conventional silencer system the design of the noise reduction system usually starts from the engine With the CSS th...

Страница 95: ...to a exhaust gas flow velocity of max 40 m s The pressure drop of a CSS element is lower compared to a conventional exhaust gas silencer 5R02 11 2 10 4 Conventional exhaust gas silencer 5R02 Yard des...

Страница 96: ...eration manual must be carefully followed Regular cleaning of the turbine is not necessary when operating on gas 12 1 Turbine cleaning system A dosing unit consisting of a flow meter and an adjustable...

Страница 97: ...Page 97 12 2 Compressor cleaning system The compressor side of the turbocharger is cleaned with the same equipment as the turbine...

Страница 98: ...Page 98...

Страница 99: ...ich represents the first set of regulations on the marine exhaust emissions The IMO Tier 3 NOx emission standard was entered into force from year 2016 It will by then apply for new marine diesel engin...

Страница 100: ...ms 14 1 Technical data and system overview 14 1 1 Ingress protection The ingress protection class of the system is IP54 if not otherwise mentioned for specific modules 14 1 2 Ambient temp for automati...

Страница 101: ...nd instrumentation are prewired on the engine 14 1 3 Local operator panel The Local operator panel LOP consist of a display unit LDU with touch screen and pushbuttons as well as an emergency stop butt...

Страница 102: ...ower unit supplies DC power to the automation system on the engine and provides isolation from other power supply systems onboard The cabinet is designed for bulkhead mounting protection degree IP44 m...

Страница 103: ...x Ethernet CAT5 Gas ValveUnit Integrated Automation System I 4 x 2 x 0 75 mm2 2 x 2 x 0 75 mm2 3 x 2 x 0 75 mm2 Engine Gas ValveUnit I 4 x 2 x 0 75 mm2 Gas ValveUnit Fuel gas supply system I 1 x 2 x 0...

Страница 104: ...s started and engine speed is raised to nominal The start mode is interrupted in case of abnormalities during the start sequence The start sequence takes about 1 5 minutes to complete 14 2 3 Stop shut...

Страница 105: ...d speed reference will share load equally Loading and unloading of a generator is accomplished by adjusting the speed reference of the individual speed control unit The speed droop is typically 4 whic...

Страница 106: ...3 x 400 50 15 0 28 4 3 x 440 60 15 0 25 7 14 4 1 3 Exhaust gas ventilation unit The exhaust gas ventilating unit is engine specific and includes an electric driven fan flow switch and closing valve F...

Страница 107: ...sharing load equally are not loaded over 100 2 Rapid loading according to the emergency curve in chapter 2 2 Loading Capacity may only be possible by activating an emergency function which generates...

Страница 108: ...pacity the recently connected generator will continue to pick up load according to the speed droop curve Also in isochronous load sharing mode a generator still on the loading ramp will start to pick...

Страница 109: ...Page 109 This page intentionally left blank...

Страница 110: ...the ship and also serve to protect the generating set bearings from possible fretting caused by hull vibration The number of mounts and their location is calculated to avoid resonance with excitation...

Страница 111: ...in the mounts is natural rubber and it must therefore be protected from oil oily water and fuel The mounts should be evenly loaded when the generating set is resting on the mounts The maximum permiss...

Страница 112: ...When installing the flexible pipe connections unnecessary bending or stretching should be avoided The external pipe must be precisely aligned to the fitting or flange on the engine It is very importan...

Страница 113: ...Page 113 This page intentionally left blank...

Страница 114: ...les below The ship designer should avoid natural frequencies of decks bulkheads and superstructures close to the excitation frequencies The double bottom should be stiff enough to avoid resonances esp...

Страница 115: ...es and forces zero or insignificant Table 16 3 Torque variations Engine Speed RPM Freq Hz Mx kNm Freq Hz Mx kNm Freq Hz Mx kN Freq Hz Mx kN 8V31SG 720 750 24 25 16 15 48 50 11 11 72 75 23 23 10V31SG 7...

Страница 116: ...rces zero or insignificant 16 2 Mass moments of inertia The mass moments of inertia of the main engines including flywheel are typically as follows 16 3 Air borne noise The airborne noise of an engine...

Страница 117: ...level emitted from turbocharger outlet to free field at engine full load and nominal speed Exhaust gas Sound Power Level in Octave Frequency Band dB ref 1pW Hz 32 63 125 250 500 1000 2000 4000 Total 8...

Страница 118: ...rsional vibration calculation is made for each installation For this purpose exact data of all components included in the shaft system are required See list below Installation Classification Ice class...

Страница 119: ...Page 119 This page intentionally left blank...

Страница 120: ...rankshaft distances are to be arranged in order to provide sufficient space between engines for maintenance and operation 18 1 2 Generating sets Fig 18 1 V engines turbocharger in free end DAAF363645...

Страница 121: ...w adequate working space The surface of maintenance platforms should be of non slippery material grating or chequer plate 18 3 Transportation and storage of spare parts and tools Transportation arrang...

Страница 122: ...Page 122 18 4 1 Service space requirement 18 4 1 1 Service space requirement engine...

Страница 123: ...Page 123 Fig 18 2 Service space requirement W8V31 W10V31 DAAF443904 Fig 18 7 Service space requirement W12V31 W14V31 W14V31 DAAF438352...

Страница 124: ...Page 124 This page intentionally left blank...

Страница 125: ...Page 125 19 Transport Dimensions and Weights 19 1 Lifting of generating sets Fig 19 1 Lifting of generating sets DAAF341224...

Страница 126: ...912 625 W 16V31SG 730 1135 912 625 Engine Weight kg Dimensions G H I W 8V31SG 830 1155 850 625 W 10V31SG 830 1155 850 625 W 12V31SG 650 1028 639 558 W 14V31SG 650 1028 639 558 W 16V31SG 650 1028 639...

Страница 127: ...Page 127 This page intentionally left blank...

Страница 128: ...roduct guides are available both in web and PDF format Engine outline drawings are available not only in 2D drawings in PDF DXF format but also in 3D models in near future Please consult your sales co...

Страница 129: ...Page 129 This page intentionally left blank...

Страница 130: ...972 m3 l litre 1000 kPa bar 0 01 Convert from To Multiply by Convert from To Multiply by kW hp metric 1 36 kgm2 lbft2 23 73 kW US hp 1 341 kNm lbf ft 737 562 Convert from To Multiply by Convert from...

Страница 131: ...Page 131 21 1 1 Prefix Table 21 1 The most common prefix multipliers Name Symbol Factor Name Symbol Factor Name Symbol tera T 1012 kilo k 103 nano n giga G 109 milli m 10 Mar mega M 106 micro 10 Jun...

Страница 132: ...W rtsil 31SG Product Guide Page 132 21 2 Collection of drawing symbols used in drawings...

Отзывы: