SECTION 5 – MAINTENANCE SCHEDULE AND SERVICE PROCEDURES
Service Procedures (cont.)
SERVICE COOLING SYSTEM (cont.)
6.
If the Exhaust Gas Recirculation (EGR) cooler must be
removed from the engine the coolant should be drained
before removal. See
Engine Service Manual
for the removal
and installation procedure.
Figure 42
Coolant drain plug for oil system module
7.
Remove coolant drain plug from bottom of oil system
module.
8.
After coolant has drained, install the coolant drain plug and
tighten to 28 N·m (18 lbf·ft).