SECTION 4 – ENGINE OPERATION
10. After the engine has reached operating temperature, the oil
pressure, at a high idle, should be 50 psi (344 kPa) minimum.
If oil pressure does not meet the minimum limit, stop the
engine and correct the problem.
NOTE: If engine starts and then stops, repeat engine
starting procedure.
If more than three attempts are
required, correct cause of no-start.
Emergency Starting
WARNING
To prevent personal injury or death, do not use
ether starting fluid to start engine.
WARNING
To prevent personal injury or death, do the
following when jump starting an engine:
•
Wear eye protection.
•
Do not smoke
•
Keep flames or sparks away from battery.
•
Protect against inhaling hydrogen gas fumes
from battery.
•
Use a 12 volt system with a negative ground.
•
Do not exceed 16.0 volts, if the ignition switch
is turned to OFF, ACC or ON during engine
cranking.
CAUTION
To prevent engine damage, do not allow metal
tools to contact positive terminal of battery.
1.
Set parking brake and shift transmission to park or neutral.
2.
Shut off lights, heater, air conditioner, and other electrical
loads in both vehicles.
3.
Make sure vehicles are not touching.
WARNING
To prevent personal injury or death, always
connect
jumper
cable
for
positive
battery
terminals first.
4.
Connect one end of the first jumper cable to the positive (+)
terminal of the dead battery or to the positive (+) terminal of
the jump start stud. Connect the other end to the positive (+)
terminal of the booster battery.