Operating the Boiler 55
You can adjust the temperature while the highlighted section
is flashing. Once the flashing stops, the current temperature
setting is stored.
Note
Ɣ
The central heating temperature cannot be
adjusted when the Outdoor Reset Control is used.
Ɣ
The central heating temperature cannot be
adjusted if the boiler is operating as a sub unit in
a cascade system. The main unit’s set temperature
will be displayed on the screen.
Ɣ
In case of outdoor reset sensor malfunction, the
boiler will operate at this set temperature.
Ɣ
Take note of the original heating temperature in
case you want to restore it to the default.
Ɣ
The default central heating supply water
temperature range is 40°C (Absolute MIN) to 85°C
(Absolute MAX).
Ɣ
The default central heating return water
temperature range is 30°C (Absolute MIN) to 65°C
(Absolute MAX).
Ɣ
You can adjust the temperature ranges in the
parameter settings menu.
Ɣ
The boiler will retain your settings during a power
outage.
11.3.2 Adjusting the DHW Temperature
To adjust the water temperature:
1. In normal operation mode, rotate the Command dial (
).
The central heating temperature (
) is highlighted on the
screen.
2. Rotate the Command dial (
) to the right to select the
DHW temperature (
).
3. Press the Command dial (
) to select the indirect DHW
temperature (
). The highlighted section will flash.
4. Rotate the Command dial (
) to the right or left to increase
or decrease the temperature.
5. Press the Command dial (
) to confirm the new
temperature.
6. Press the Back button (
) to return to normal operation
mode, or rotate the Command dial (
) to adjust other
operation conditions.
You can adjust the temperature while the display is flashing.
Once the display stops flashing, the current temperature setting
is stored.
Note
Ɣ
Take note of the original DHW indirect supply
temperature in case you want to restore it to the
default.
Ɣ
The default DHW temperature range is 40°C
(Absolute MIN) to 85°C (Absolute MAX).
Ɣ
You can adjust the temperature ranges in the
parameter settings menu.
Ɣ
The boiler will retain your settings during a power
outage.
Ɣ
System/Regular boilers: The default DHW Supply
Temperature range is 40°C (Absolute Min) to 85°C
(Absolute Max).
Ɣ
Combi boilers: The default DHW Temp range is
30°C (Absolute Min) to 60°C (Absolute Max).
Содержание LCB700-21RS
Страница 78: ...78 Appendices 13 2 2 Burner Cover Flame Tube...
Страница 80: ...80 Appendices Oil Pump Coupling Orifice Swirl Plate Oil Pump Motor Oil Pump Intake Pipe Flame Holder Assembly...
Страница 86: ...86 Appendices 13 2 5 DHW Parts 20 11 10 13 14 12 19 23 22 27 21 26 25 28 24 16 17 18 6 7 8 9 15 4 5 2 3 1...
Страница 92: ...Memo...
Страница 93: ...Memo...
Страница 94: ...Memo...
Страница 95: ......