44 Connecting Electrical Supplies
9.4 Connecting Applications - Low Voltage (DC) Application Part
These connections are low voltage DC only and 240 V AC is not to be fitted to these terminals. Doing so may damage the PCB and will not
be covered under warranty.
9.4.1 Connecting the OpenTherm
The boiler is designed to be connected to an OpenTherm. The OpenTherm cables are to be connected to the CONN2 in the low voltage
(DC) application part.
Room Controller
OpenTherm Protocol
$0//
$0/&
$0/)
&21(
$0/)
Low Voltage (DC)
Application
Part
Note
OpenTherm® is an industry standard modulating control available from several control manufacturers and the LCB700 boiler
has an OpenTherm® interface. This enables our modulating range of OpenTherm® room controls to be connected without any
further modifications.
9.4.2 Connecting the Cylinder Stat
The boiler is designed to be connected to a cylinder stat. The thermostat cables are to be connected to the CONH2 in the low voltage (DC)
application part.
Cylinder Stat
$0//
$0/&
$0/)
&21(
$0/)
Low Voltage (DC)
Application
Part