50
| NAUCON-1000 – USER MANUAL
RELAY 1
–
fault:
→ Cable or horn incorrectly connected to
J7
.
RELAY 2
–
fault:
→ Cable or horn incorrectly connected to
J8
.
RELAY 3
–
fault:
→ NG out or LED strip incorrectly connect
-
ed to
J9
.
12V IN
–
fault:
→ No 12V/AC supply.
12V FUSE
–
fault:
→ Fuse F1 is blown.
24V IN
–
fault:
→ No 24V/AC supply.
24V FUSE
–
fault:
→ Fuse F2 is blown.
NAUNET 24V
–
fault:
→ Fuse F2 is blown.
NAUNET GND
–
fault:
→ Possible short circuit on equipment
connected to the NGMCB.
EXTRA 24V
–
fault:
→ Fuse F12 is blown.
*
1
EXTRA RELAY
–
fault:
→ N/A, not used.
*
1
DCF77
–
fault:
→ NG-DCF has a bad reception or it is not
installed correctly.
*
2
DIP1
–
default:
→ 0 – 00000000
DIP2
–
default:
→ 0 – 00000000
DIP3
–
default:
→ 11 – 00001011
DIAGNOSTIC FOR WIRELESS POWER
SHOWS CHECKSUM:
→ 0-17 and can only be edited when a test
is started.
Start the wireless test:
Press
START TEST
and thereafter
RESET TEST
:
TOTAL RETRY COUNT
0 → OK
/
Counting →
ERROR
Error:
Fault in the communication.
SEND PACKETS
Counting
*
3
→ OK
0 → Error:
The radio in the NAUCON-1000
might be damaged.
RECEIVE PACKETS
Counting
*
3
→ OK
0 → Error:
The radio on the NGMCB might
be damaged.
BOARD RECEIVES
Counting
*
3
→ OK
0 → Error:
The radio in the NAUCON-1000
might be damaged.
PACKETS LOSS
0 → OK
Counting → Error:
Lost packets.
What is the reason why errors occur and testing.
Diagnostic troubleshooting guide
*
1
Only displayed on scoreboards with
NGP-85 mounted.
*
2
Only displayed on scoreboards with
NG-DCF module mounted.
*
3
Should show almost the same value.