8
Console Service Mode – x624 / x626 series (MY14) Consoles
The Console Setup Mode lets you input the date and time, set the units of measurement to either English or Metric, change
the machine type, control the sound settings ( on/ off), or see maintenance statistics (Total Run Hours – for service technician
use only).
1. Hold down the PAUSE/END button and Right button together for 3 seconds while in the Power-Up Mode to go into the
Console Setup Mode.
Note:
Push PAUSE/END to exit the Console Setup Mode and return to the Power-Up Mode screen.
2. The Console display shows the Date prompt with the current setting. To change, push the Increase/Decrease buttons to
adjust the currently active value (flashing). Push the Left/Right buttons to change which segment is the currently active
value (month / day / year).
3. Push OK to set.
4. The Console display shows the Time prompt with the current setting. Push the Increase/Decrease buttons to adjust the
currently active value (flashing). Push the Left/Right buttons to change which segment is the currently active value (hour /
minute / AM or PM).
5. Push OK to set.
6. The Console display shows the Units prompt with the current setting. To change, push OK to start the Units option. Push
the Increase/Decrease buttons to change between “MILES” (Imperial English units) and “KM” (metric units).
Note:
If the units change when there is data in User Statistics, the statistics convert to the new units.
7. Push OK to set.
8. The Console display shows the Machine Type prompt with the current setting. This menu option appears in the x624
series console only (not the x626 series consoles). Push the Increase/Decrease buttons to change between “BIKE” and
Elliptical (“ELIP”).
9. Push OK to set.
10. The Console display shows the Sound Settings prompt with the current setting. Push the Increase/Decrease buttons to
change between “ON” and “OFF”.
11. Push OK to set.
12. The Console display shows the TOTAL RUN HOURS for the machine.
To go to the next Console Setup Mode prompt, push the OK button.
To enter the Manufacturing Menu (MFG Menu), hold down the PAUSE/END button and Down button together for 3
seconds. The Console display shows the Firmware Version string. Push the Up/Down buttons to move through the MFG
Menu options. Push OK to make a selection.
a. ENTER MFG TEST – This option is intended for use on the manufacturing production line only. It is a chained series
of tests similar to the tests listed below, but optimized to be run on the production line. This chained test should not
be used anywhere but on the production line.
b. DEBUG TERMINAL – Not used.
c. MOVE LIFT – (E626 elliptical only) Used to adjust a new lift motor. The Console displays “UP MX DN MN RT CAL”: Up
arrow will move the lift motor to the maximum position; Down arrow will move the lift motor to the minimum position;
Right arrow will perform a lift motor calibration by moving the lift motor to its minimum and maximum position. Note:
Lift motor calibration is no longer required, so calibration is not needed.
d. RESET MFG NVM – Resets MFG NVM (non volatile memory). Must be run before lift motor calibration if a valid lift
table exists in NVM (lift motor has been calibrated before).
e. RUN BEEP TEST – Sounds each system beep / tone / sequence in order. Press any key to exit
f. RUN BUTTON TEST – The Console display shows the function of each button as buttons are pressed. If the display
shows an incorrect function, the overlay on the Console may be incorrect for that model. If the display does not show
a function, the firmware version may be incorrect. No beeps are sounded during this test.
To exit the test, push and hold one of the long key sequences (i.e. long Pause / End + Right or long Pause / End +
Down).
g. RUN LED TEST – Drives LEDs to the following states:
1.
All LEDs On 1 second