background image

12 

 

 

 

 

 

 

 
LED status identification: 

On start up: 

LED indicator 

Status 

Steady "Blue" light 

Battery is normal, goes into flashing "Blue" light 
standby mode after 5 seconds.  

"Blue" and "Red" 
lights alternating 

Battery low. Replace battery as soon as possible. 
Goes into standby mode after 5 seconds.  

Steady "Red" light 

Battery empty, replace battery. 

 

After start up: 

LED indicator 

Status 

Flashing "Blue" 
light 

Standby mode. The moisture alarm is active, and 
the system is ready for vacuum indication 
whenever a vacuum is detected. 

Flashing "Red" light 
with audio sounds. 

Moisture is detected.  

Flashing "Yellow" 
light 

Some vacuum is detected, target vacuum level is 
not reached. 

Steady "Green" 
light 

Target vacuum level is reached. 

Rapidly flash 
"Yellow" light 

Vacuum is dropping. (Will occur only after target 
vacuum level is reached) 

Rapidly flashing 
"Red" light 

Vacuum is totally lost. Circuit stalled until switched 
off.  (Will occur only after target vacuum level is 
reached) 

(Optional)  Vacuum  valve  can  be 
attached  to  the  housing  via  one 
of  the  accessory  port  for 
conducting  a  vacuum  seal  test. 
Please refer to the manual of the 
vacuum valve for more details of 
the operation.  

 

Содержание NA-A6000

Страница 1: ...0 ...

Страница 2: ...em through the innovative designs of our products We strive to achieve a high level of user friendliness by allowing stress free installation and easy operation of all important functions of the camera Each housing is individually inspected and water pressure tested to ensure optimum quality Please read this manual carefully before using the housing this will maximise its performance as well as it...

Страница 3: ...thin the housing 4 NAUTICAM accepts no liability for any loss of captured images or the inability to capture images even if it is due to the malfunctioning or leakage of the housing 5 This warranty only applies to products purchased from authorised NAUTICAM dealers and does not extend beyond the original retail purchaser 6 Unauthorised modifications and or repairs of the housing will automatically...

Страница 4: ...struction manual 3 Spare silicone rubber housing o ring 4 O ring remover 5 CR2450 battery for moisture alarm 6 Lubricant 7 Set of Allen keys Spare silicone rubber o ring Lubricant Set of Allen keys CR2450 battery O ring remover ...

Страница 5: ...ng if the port is installed as this may lead to a pressure difference between the atmosphere and inside the housing 6 Care must be taken when opening the housing as pressure may build up inside the housing which increases the opening force 7 Do not open the product in a wet or sandy environment Protect the interior from moisture and debris in order to prevent malfunction or leakage 8 Do not store ...

Страница 6: ... Specifications 6 Identification of Parts 7 Preparation of the Housing 10 Opening and Locking the Housing 13 Installing the Camera 14 Mounting the Port 15 Care and Maintenance 17 Optional Accessories 18 ...

Страница 7: ...hout camera Buoyancy Slightly negative Depth rating 100 metres Features Moisture alarm Blinking LED and audible alarm TTL capability Optical fibre mount included for external strobes connection utilising the camera s pop up flash as trigger Port mount Patented easy port installation system Control dial Easily reached by thumb EVF LCD switch Switch between EVF and LCD with the flick of a switch ...

Страница 8: ...sh up off lever 6 Housing lock safety button 2 Mode dial 7 Housing lock 3 Control dial 8 M10 strobe mounting base 4 C1 button 9 ON OFF switch 5 Shutter release lever 10 Lens release button 1 2 3 4 8 7 5 9 10 6 ...

Страница 9: ...ical fibre mount 16 Port release safety button 13 Port alignment index 17 Port lock release lever 14 M16 accessory port 18 1 4 20UNC tripod socket x 2 11 18 14 The maximum length of screws that can be used with the tripod sockets is 4mm 12 13 15 16 17 ...

Страница 10: ...7 Right selection ISO button 21 Menu button 28 Set button 22 AEL button 29 Left selection Drive mode button 23 Movie button 30 Down selection Exposure comp Image index button 24 Fn button 31 C2 Delete button 25 Control wheel 32 Playback button 19 21 22 23 25 20 24 26 28 27 29 32 30 31 ...

Страница 11: ...oove located in the rear part of the housing is free from any foreign material the groove can be cleaned with the aid of a microfiber cloth 3 Place the O ring into the groove 4 To install the optical fibre mount for external strobe connection fasten it with the screws provided to the threaded sockets of the accessory coldshoe as shown ...

Страница 12: ... by contacting the two wires near the bottom of the housing with a damped cotton bud the alarm should start giving out a repeating beep sound along with a flashing red light The beep sound and the light should keep on going for 5 seconds after the removal of the damped cotton bud 2 Switch the alarm on The LED light will turn blue for five seconds indicating the battery is normal Then it goes into ...

Страница 13: ...ication whenever a vacuum is detected Flashing Red light with audio sounds Moisture is detected Flashing Yellow light Some vacuum is detected target vacuum level is not reached Steady Green light Target vacuum level is reached Rapidly flash Yellow light Vacuum is dropping Will occur only after target vacuum level is reached Rapidly flashing Red light Vacuum is totally lost Circuit stalled until sw...

Страница 14: ...k reaches the Open position as shown 3 Close the housing while the housing lock is in the Open position 4 Turn the housing lock clockwise for 270 until the lock reaches the lock position as shown Confirm that the white indicator line on the safety button is visible 1 Press the housing lock safety button ...

Страница 15: ...ds then attach the saddle to the camera by tightening the screw to the tripod socket of the camera 3 Install the camera by sliding the attached saddle along the rail in the housing until it cannot go in any further 4 Please make sure the eyepiece cup is not attached to the camera Confirm that the red camera saddle locks are in the engaged position before closing the housing ...

Страница 16: ...r any damage and lightly coat it with the provided lubricant before placing it back into its groove 2 Verify that the port opening of the housing is clean and free from foreign material 3 Push the safety button of the port locking lever downwards 4 Turn the port locking lever to the release position as shown 5 Lift housing cap ...

Страница 17: ...n any further 8 Lock the port into place by turning the port locking lever to the inward position To ensure that the port is securely mounted confirm that the green line on the safety button of the port locking lever is visible 9 To remove the port from the housing simply turn the port locking lever to the outward position and gently pull it out ...

Страница 18: ... damage Also check that the O ring retains its original circular shape never stretch the O ring excessively or remove it with a sharp object The O ring groove should be cleaned to ensure it is free from any salt deposit or foreign material lightly coat the O ring with the provided lubricant before reinstalling it in the groove A damaged O ring should be discarded immediately and replaced only with...

Страница 19: ...18 P N 17454 NA A6000 LCD window for Nauticam enhanced viewfinders P N 25612 M16 Vacuum Valve ...

Страница 20: ...19 ...

Отзывы: