NARB14 Dual ND500II (IP66) – IS03013

 

Page 5

 

Information Sheet 

Issue 1.0

 

(h)

 

Connect a 250-watt, precision, 50-
ohm, resistive dummy load to 
transmitter A's RF output coaxial 
connector (1A7J2), using a customer-
provided coaxial cable.

 

 

(i)

 

Set transmitter B's

 

POWER

 

switch to

 

ON

 

(j)

 

Set transmitter A's

 

LOCAL

/

REMOTE

 

switch to

 

LOCAL

(k)

 

Set transmitter A's

 

POWER

 

switch to

 

ON

 

and perform servicing and/or testing 
procedures on transmitter A.

 

 

(l)

 

On successful completion of 
maintenance procedures, set 

POWER

 

switches of both transmitters to

 

OFF

 

(m)

 

Remove the antenna system cable 
from transmitter B's RF output 
connector (2A7J2) and reconnect it to 
the dual cabinet's RF output coaxial 
connector (J1).

 

 

(n)

 

Disconnect the dummy load from 
transmitter A’s RF output coaxial 
connector (1A7J2).

 

 

(o)

 

Restore coaxial cables to their original 
connections.

 

 

(p)

 

Remove jumper connected in step (c).

 

 

(q)

 

Set 

POWER

 

switch of both transmitters 

to

 

ON

 

and set their

 

LOCAL

/

REMOTE

 

switches to the desired position.

 

7.  CHECK OF CHANGEOVER UNIT 

Check the operation of the main/standby 

changeover function as follows: 

 

(a)

 

Verify both transmitters are turned on 
and their switches are set as specified 
for 'Operating Setting' in table 4-1 of 
the ND500II instruction manual.

 

 

(b)

 

Verify transmitter A is producing the 
desired RF output and transmitter B's 
RF output is inhibited

 (

MAIN 

TRANSMITTER – SELECT

 

switch set to

 

A

). 

 

(c)

 

Set transmitter A's

 

KEYING

 

switch (S1) 

to

 

OFF

 

(d)

 

After a time delay (between twenty 
and eighty seconds), transmitter A's 
RF output should be inhibited and 
transmitter B should be enabled and 
producing the desired output.

 

 

NOTE 

If A11J4-21 of transmitter B is connected to 
ground, transmitter B's 'standby 1' code 
variation will be transmitted when transmitter 
B turns on.

 

 

(e)

 

Set transmitter A's

 

KEYING

 

switch (S1) 

to

 

ON

 

(f)

 

Reset transmitter A by setting its

 

POWER

 

switch (S3) to

 

OFF

 

and then 

return it to

 

ON

Содержание ND500II

Страница 1: ...Cove Road Hackett s Cove NS Canada B3Z 3J4 T 1 902 823 2233 F 1 902 823 3183 info nautel com U S customers please contact Nautel Maine Inc 201 Target Industrial Circle Bangor ME 04401 T 1 207 947 820...

Страница 2: ......

Страница 3: ...escribes the operation of both transmitters A ND500II 11x x20 and B ND500II 01x x20 The following provides a brief description for transmitters that are connected in a main standby dual installation S...

Страница 4: ...ctor SHTDN ALM A signal will be applied to 3A1J4 23 from A11J4 17 shutdown of transmitter A causing a ground to be applied to RMT CHGOV ALM outputs 3A1J1 8 and 3A1TB3 6 indicating the standby transmit...

Страница 5: ...f the cabinet s RF output coaxial connector J1 Remove connector cap h Verify that pre routed AC power cable W1 is connected between transmitter A s AC power cable receptacle 1U2 and the cabinet s AC p...

Страница 6: ...should not be used for connection between transmitter B and an external dummy load A user provided coaxial cable should be obtained f Set transmitter B s LOCAL REMOTE switch to LOCAL g Set transmitte...

Страница 7: ...jumper connected in step c q Set POWER switch of both transmitters to ON and set their LOCAL REMOTE switches to the desired position 7 CHECK OF CHANGEOVER UNIT Check the operation of the main standby...

Страница 8: ...used as voltage source for external SWR ALARM and BATTERY STATUS circuits connect circuit VDC to 3A1TB2 8 3A1J1 2 If an external DC power supply is used as voltage source for external SWR ALARM and BA...

Страница 9: ...6 13 P2 11 14 White 22 P6 14 P2 7 15 White 22 1 Conductor P6 15 P2 19 15 Shield 22 Shielded P6 16 P2 8 16 Black 22 P6 17 P2 23 17 White 22 P6 18 P2 9 18 White 22 P6 19 P2 6 19 White 22 P6 20 P2 2 20 W...

Страница 10: ...Ground 2 Safety Ground 50 Grn Yel 14 Safety Ground J2 Ground 51 Grn Yel 14 Additional wiring when remote control unit unit 4 is used P12 3 P13 36 100 White 22 P12 4 4TB1 1 101 White 22 P12 5 P13 24 1...

Страница 11: ...2 P2 Connector D Sub 25 Socket 183 5010 183 5010 37338 P3 Connector D Sub 25 Socket 183 5010 183 5010 37338 P4 Connector Coaxial BNC Plug 50ohm Crimp JDP24 225395 7 09482 P5 Connector Coaxial BNC Plug...

Страница 12: ...JS43 163A16279X 31781 J6 Connector BNC Receptacle PWB Mt JF35 R141 426 000 0GP12 J7 Connector BNC Receptacle PWB Mt JF35 R141 426 000 0GP12 J8 Conn Socket D Sub 9 Pin Vertical PWB JS50 164A16669X C305...

Страница 13: ...P5 SAFETY LIGHTNING STATION DC SUPPLY A7J3 P7 A11TB2 2 14 19 16 15 A7J2 P11 1 XMTR A A11J4 5 9 7 6 1 1 18 17 2 A11J4 8 INCREASE A DECREASE A 15VDC ATU A GND A SERVO INHB A RMT SHTDN ALM A B VDC A 24VD...

Страница 14: ...A 11 20 11 15 P6 P2 1 STATION LIGHTNING SAFETY GROUND A7J3 P7 21 20 12 22 A11TB2 2 1 DC SUPPLY DC SUPPLY GND A 3 4 A11J4 XMTR A RMT ON OFF A RMT PWR TRIM A STBY ON OFF A STBY 2 A STBY 1 A A11J4 1 7 9...

Страница 15: ...13 J1 1 16 K1 E 3 5 7 K1 A 1 12 J1 1 16 K2 E CR6 3 5 7 K2 A 13 11 9 K1 C 4 6 8 K1 B 1 2 RMT XMTR ON STAT 9 4 J1 B VDC 1 2 3 NO COM NC RMT SHTDN ALM 3 J1 19 J1 6 15VDC B STBY ON OFF A 2 J4 RMT ON OFF...

Страница 16: ...Dimensions mm inches Figure 4 Assembly Detail Dimensional Information Dual ND500II Transmitters IP66 NARB14 Cabinet Version 1 0 Not to Scale Drawing No Sheet 1 of 1...

Страница 17: ...Dimensions mm inches Figure 5 Assembly Detail NAX223 Dual Transmitter Interface Assembly Version 1 0 Not to Scale Drawing No Sheet 1 of 1...

Страница 18: ...Dimensions mm inches Figure 6 Assembly Detail NAPI66 Dual Transmitter Interface PWB Version 1 0 Not to Scale Drawing No Sheet 1 of 1...

Отзывы: