7-6 

 

01 September 2004 

  

Table 7-2  Ref Des Index - NAB05EA 48 Volt Battery Charger (Continued) 

 
 

USE 

REF 

NAME OF PART 

NAUTEL'S 

JAN/MIL/OEM 

 OEM 

  CODE 

DES 

AND DESCRIPTION 

PART NO. 

PART NO. 

CODE 

 

   

 

 

A1R29 

Resistor, Metal Film, 1800 Ohms, 2% 1/2W 

RAP10 

RL20S182G 

35005 

   

 

 

A1R30 

Resistor, Metal Film, 1800 Ohms, 2% 1/2W 

RAP10 

RL20S182G 

35005 

   

 

 

A1R31 

Resistor, Metal Film, 1000 Ohms, 2% 1/2W 

RAP09 

RL20S102G 

35005 

   

 

 

A1R32 

Resistor, Metal Film, 390 Ohms, 5% 2W 

RBP33 

GS-3 T0 3900J 

35005 

   

 

 

A1R32 

Resistor, Metal Film, 390 Ohms, 5% 2W 

RBP33 

GS-3 T0 3900J 

35005 

   

 

 

A1U1 

Rect/Assy, Diode, Bridge 200V 2A 

UA27 

VS247 

83003 

 

   A1U2  IC, 

Voltage 

Regulator, 

+15V 

UT19 

MC78M15CT 

04713 

 

   A1U3  IC, 

Operational 

Amplifiers, 

Quad 

UC15 

MC3403L 

04713 

 

   A1U4  IC, 

CMOS, 

Oscillator/Timer 

UB12 

MC14541BCP 

04713 

   

 

 

A1U5 

IC, CMOS, Quad, 2-input NOR Gates 

UB01 

MC14001BCP 

04713 

 

   A1XU3 Socket, 

Integrated 

Circuit, 

14-Pin 

UD41 

1814AG111D 

91506 

 

   A1XU4 Socket, 

Integrated 

Circuit, 

14-Pin 

UD41 

1814AG111D 

91506 

 

   A1XU5 Socket, 

Integrated 

Circuit, 

14-Pin 

UD41 

1814AG111D 

91506 

 

   C1 

Capacitor, 

Electrolytic, 

1100uF, 

75V 

CYP01 

500112U075AA2B 

00853 

 

   CR1 

Diode, 

Power 

Rectifier, 300V, 40A 

QK17 

1N1187A 

81483 

 

   DS1 

Diode, 

Light 

Emitting, 

Green 

QK12 

HLMP-3554 

50434 

  /1   

 

F1 

Fuse, 5A, 250V, Slow, 3AB 

FB33 

MDA5 

71400 

  /2   

 

F1 

Fuse, 3A, 250V, Slow, 3AG 

FA10 

313003 

75915 

   

 

 

F2 

Fuse, 5A, 250V, Slow, 3AB 

FB33 

MDA5 

71400 

 

   L1 

Inductor 

Assembly 

147-1322 

147-1322 

37338 

   

 

 

P1 

MTA, Closed End Housing, 12-Pin, 22 AWG 

JU26 

1-644463-2 

00779 

   

 

 

Q1 

Thyristor, Power, 50A, 800V 

QM26 

SLT24-/08C UNF 

SEMIK 

 

   Q2 

Thyristor, 

Power, 

50A, 

800V 

QM26 

SLT24-/08C.UNF 

SEMIK 

 

   R1 

Resistor, 

Wirewound, 

0.075 

Ohms, +1% 5W 

RS14 

LVR-5  0.075 

35005 

   

 

 

R2 

Resistor, Wirewound, 1000 Ohms, 5% 5W 

RWP10 

RS5-1000 Ohms-5% 

35005 

   

 

 

S1 

Switch, Toggle, SPST, ac/dc/CSA Rated 

SCP43 

S1A 

63426 

 

   T1 

Transformer 

Assembly 

147-1321 

147-1321 

37338 

   

 

 

TB1 

Terminal Block, 6-pos, Single, 1 Sd 

JR03 

GBS-6 

73631 

   

 

 

TB2 

Terminal Block, 6-pos, Single, 1 Sd 

JR03 

GBS-6 

73631 

 

   U1 

Probe 

Assembly 

147-1318 

147-1318 

37338 

 

   U2 

EMI 

Filter, 

Mod 

139-8227 

139-8227 

37338 

 

   XDS1  Socket, 

LED 

QK25 

PS-200-B 

15513 

   

 

 

XF1 

Fuseholder, Panel, 20A, 250V, Type 3AG 

BAP30 

342012 

75915 

   

 

 

XF2 

Fuseholder, Panel, 20A, 250V, Type 3AG 

BAP30 

342012 

75915 

 
 
 

NOTE

 

  -  Denotes used when ac power source is 115 V ac (line-to-neutral, 50/60Hz) 

 

 

  -  Denotes used when ac power source is 230 V ac (line-to-neutral, 50/60Hz) 

 

 

/1  -  Denotes used on NAB05E/01 variations 

 

 

/2  -  Denotes used on NAB05E/02 variations 

 

Содержание NAB05E

Страница 1: ...tt s Cove NS Canada B3Z 3J4 Phone 207 947 8200 Phone 902 823 3900 Fax 207 947 3693 Fax 902 823 3183 ISO 9002 REGISTERED ISO 9001 REGISTERED Copyright 2004 NAUTEL All rights reserved TECHNICAL INSTRUCT...

Страница 2: ...ember 2004 Warranty 2 0 01 September 2004 Contents 1 0 01 September 2004 Contents 2 0 01 September 2004 Contents 3 0 01 September 2004 Contents 4 Blank 1 1 0 01 September 2004 1 2 0 01 September 2004...

Страница 3: ...NCH CASUALTY S NOSE AND EXHALE TWO SLOW BREATHS INTO CASUALTY Figure 5 h REMOVE YOUR MOUTH and check for breathing Figure 6 i CONTINUE GIVING ONE BREATH EVERY FIVE SECONDS without interruption If any...

Страница 4: ...do not handle affected areas more than necessary 7 Do not apply salves grease etc to burns 8 Do not remove burned clothing which adheres to the skin or break blisters 9 Cover the burn with a dry steri...

Страница 5: ...l the patient is breathing on his own or until medical aid arrives Survival rates can be quite high if cardio pulmonary resuscitation is started within 3 to 4 minutes of the injury being received ACT...

Страница 6: ...M OXIDE ceramic which is non hazardous during normal device operation and under normal device failure conditions These devices are specifically identified in the equipment manual s parts list s DO NOT...

Страница 7: ...costs incurred in returning the part assembly to the Customer 5 Warranty replacement parts and repair which are provided under items 2 or 3 shall be guaranteed for a period of ninety days from date o...

Страница 8: ...hirteen months from shipment repair and exchange of modules is at no charge to the customer When the warranty has expired a charge of 80 of the list price for all exchanged modules is made If the faul...

Страница 9: ...N ON OVERVIEW 2 2 2 2 10 FULL WAVE RECTIFIER OVERVIEW 2 3 2 3 DETAILED DESCRIPTION 2 3 2 3 1 AC POWER SUPPLY 2 3 2 3 2 23 VDC POWER SUPPLY 2 3 2 3 3 15 VDC POWER SUPPLY 2 3 2 3 4 DIGITIZER 2 4 2 3 5 R...

Страница 10: ...NG INSTRUCTIONS 4 1 GENERAL 4 1 4 2 EMERGENCY SHUTDOWN PROCEDURE 4 1 4 3 PERSONNEL SAFETY 4 1 4 4 CONTROLS AND INDICATORS 4 1 4 5 TURNING ON THE BATTERY CHARGER 4 1 4 6 OPERATING PRECAUTIONS 4 1 4 7 F...

Страница 11: ...MFR PART NO COLUMN 7 2 7 6 6 OEM CODE COLUMN 7 2 LIST OF ILLUSTRATIONS Number Title Page 2 1 Timing Information 2 7 6 1 Waveforms 6 4 SD 1 Block Diagram NAB05E Battery Charger SD 1 SD 2 Electrical Sch...

Страница 12: ...m of the cabinet and connected to two terminal blocks on the rear panel inside the cabinet The battery charger circuitry comprising a supply transformer choke two thyristors two fuses one power on off...

Страница 13: ...loscope with a calibrated time base Monitor waveforms during trouble shooting procedures Dc Power Supply Any good quality dc power supply 0 70 volts Simulate precise full charge no load battery voltag...

Страница 14: ...n parallel When the ac power source voltage is 230 V ac 50 Hz the primary windings are connected in series One set of secondary windings provides 17 5 V ac RMS for the low voltage power supplies The s...

Страница 15: ...effectively increasing the time required to generate a master reset signal as the batteries approach their fully charged condition 2 2 7 EIGHT SECOND TIMER OVERVIEW An oscillator timer integrated cir...

Страница 16: ...reset level A choke is installed in the centre tapped ac return path to filter the average dc voltage It also contains a free wheeling diode that prevents oscillations when the thyristor control pulse...

Страница 17: ...d by the status of the eight second timer When A1Q2 is turned on the collector of A1Q1 will be clamped to the dc reference level and the switching action of A1Q1 will be inhibited When A1Q2 is turned...

Страница 18: ...an open circuit and it will have no influence on the operation of transistor A1Q1 2 3 8 CHARGING CURRENT CONTROL The charging current control circuit consists of operational amplifier A1U3C and its as...

Страница 19: ...to TB2 1 thru inductor L1 as the negative voltage terminal for voltages developed by the switched full wave rectifier The 75 0 75 RMS ac voltage from T1 s secondary winding is applied to the anodes o...

Страница 20: ...48 VOLT BATTERY CHARGER NAB05E Page 2 7 01 September 2004 Figure 2 1 Timing Information...

Страница 21: ...ampere maximum load The battery cable enters the battery charger through a cable entry hole in the bottom of its cabinet Individual wires are connected to TB2 2 and TB2 1 UNPACKING 3 4 The battery ch...

Страница 22: ...ify that the wiring connected to the primary winding taps of power transformer T1 is connected to accommodate the voltage of the ac power source to be sued as follows a When ac power source voltage is...

Страница 23: ...emperature sensor is located where it will not be exposed to corrosive acids or gasses 3 8 6 POST INSTALLATION INSPECTION Visually inspect the battery charger s interior after installation and prior t...

Страница 24: ...ING ON THE BATTERY CHARGER 4 5 There are no special turn on procedures Verify the requirements of paragraph 3 8 have been satisfactorily completed and observe the precautions specified in paragraph 4...

Страница 25: ...the battery charger They should be maintained at their fully charged state unless the equipment that is connected to them is or has recently been drawing current from the batteries Check the specific...

Страница 26: ...spect as follows 5 3 1 OPERATION OF EQUIPMENT Observe the precautions presented in section 4 when operating the battery charger 5 3 2 ADJUSTMENT PRE REQUISITES Prior to adjusting the battery charger e...

Страница 27: ...rom nominal Preset the output of the variac to 230 V ac or 115 V ac depending on the ac source c Disconnect battery bank from battery charger by disconnecting the interconnecting wiring from TB2 2 and...

Страница 28: ...source Set the variac s output to 10 above the nominal V ac and verify the ammeter reading does not increase by more than five percent y Simulate a 10 decrease in the ac power source Set the variac s...

Страница 29: ...easure the specific gravity of the electrolyte to verify the battery charger is functioning normally If the batteries being charged do not have provision to check their electrolyte periodically measur...

Страница 30: ...16 Reference Designations for Electrical and Electronic Parts and Equipments Each electrical symbol has been identified with its basic reference designation To obtain the full reference designation fo...

Страница 31: ...efective fuse F2 b No pulses to turn on b Check pulses at gates of Q1 Q2 c Battery fully charged c No corrective action necessary Battery not charging a CHARGE VOLTAGE potentiometer a Adjust battery c...

Страница 32: ...2 XF2 Side 13 White 16 XF2 Centre R1 04 14 White 16 R1 04 C1 15 White 16 P1 1 Q2 Gate 16 White 22 P1 2 Q1 Gate 17 White 22 P1 3 XDS1 Cathode 18 White 22 P1 7 T1 9 19 White 22 P1 8 C1 Cathode 20 White...

Страница 33: ...5 0 Volts division 5 0 Milliseconds division Centre line at 10 Volts DIGITIZER OUTPUT Junction A1R2 CR1 1 0 Volts division 5 0 Milliseconds division Centre line at dc reference level RAMP GENERATOR O...

Страница 34: ...VOLT BATTERY CHARGER NAB05E Page 6 5 01 September 2004 THYRISTOR TURN ON CONTROL PULSES Junction A1R2 CR1 5 0 Volts Division 5 0 Milliseconds division Centre line at 10 Volts Figure 6 1 Waveforms Shee...

Страница 35: ...de Parts that are common to all variations will not have an entry in this column Notes at the end of each table explain the code s significance 7 6 2 REF DES COLUMN This column con tains the reference...

Страница 36: ...not listed in the catalog when this listing was compiled have been assigned a unique five letter code This code is assigned arbitrarily and has no other significance The manufacturers identified for...

Страница 37: ...d Massachusetts 02062 35005 Dale Electronics Canada Limited 18 Howden Road Scarsborough Ontario Canada M1R 3E6 USA customers use 91637 37338 Nautel Limited 10089 Peggy s Cove Road Hackett s Cove Nova...

Страница 38: ...ernational Rectifier 9220 Sunset Boulevard PO Box 2321 Terminal Annex Los Angeles California 90069 83003 VARO Incorporated PO Box 401426 2203 Walnut Street Garland Texas 75040 89473 General Electric D...

Страница 39: ...s 2 1 2W RAP09 RL20S102G 35005 A1R3 Resistor Metal Film 100K Ohms 2 1 2W RAP17 RL20S104G 35005 A1R4 Resistor Metal Film 1200 Ohms 2 1 2W RC38 RL20S122G 35005 A1R5 Resistor Metal Film 10K Ohms 2 1 2W R...

Страница 40: ...B 00853 CR1 Diode Power Rectifier 300V 40A QK17 1N1187A 81483 DS1 Diode Light Emitting Green QK12 HLMP 3554 50434 1 F1 Fuse 5A 250V Slow 3AB FB33 MDA5 71400 2 F1 Fuse 3A 250V Slow 3AG FA10 313003 7591...

Страница 41: ...Figure SD 1 Block Diagram NAB05 Battery Charger Page SD 1 01 September 2004...

Страница 42: ...Figure SD 2 Electrical Schematic NAB05E Battery Charger Page SD 2 01 September 2004...

Страница 43: ...Figure MD 1 Assembly Detail NAB05E Battery Charger Page MD 1 01 September 2004...

Страница 44: ...Figure MD 2 Assembly Detail Battery Charger PWB P N 147 1310 08 Page MD 2 01 September 2004...

Страница 45: ...Figure MD 3 Dimensional Information NAB05 Battery Charger Page MD 3 1 01 September 2004...

Отзывы: