background image

Single Use Pre-

Sized XactTrace™ Belt System User Instructions 

Cleaning 

Wipe the snap sensor and RIP processor modules (if used) clean with a 
moist cloth containing hospital-grade laundry detergent, and dry with a 
clean, dry cloth. Take care to avoid contacting the sensor connector and 
plug of the snap sensors or processor modules with the cleaning 
solution. The snap sensors and RIP processor modules (if used) do not 
require sterilization. 

The belts should be discarded after use, and do not require cleaning. 

Labeling Definitions 

 

This symbol indicates that the item should not be reused and 
is intended for a single-use only. 

Maintenance 

No special maintenance of the Single Use Pre-Sized XactTrace belt 
system is required.  

Warranty 

Embla warrants the sensor to be free of defects in materials and 
workmanship for 6 months from the date purchased. The sole liability of 
Embla and our distributors is limited to replacement or repair of the 
product at the option of Embla, with no charge for parts or labor if any 
part is proven to be defective in workmanship, performance, or materials 
during the warranty period. Under no circumstances shall Embla or our 
distributors be liable for any loss of revenues or damage, direct, 
consequential, or incidental, including loss of profit, property damage, or 
personal injury arising from the use of, or the inability to use this product. 
This warranty is intended for the original buyer and is in lieu of all other 
warranties or previous agreements, expressed or implied. This warranty 
is rendered void if the product is used for anything other than its intended 
purpose or is subject to abuse, misuse, tampering, neglect or 
unauthorized modifications. Use of this product constitutes acceptance of 
this warranty in total. 

Содержание XactTrace

Страница 1: ...and attaching the belts storage and cleaning Intended Use XactTrace is intended to measure respiratory effort to assist in the diagnosis of sleep disorders or sleep related respiratory disorders The r...

Страница 2: ...other words in the presence of flammable liquids such as an anesthetic mixture with air or with oxygen or nitrous oxide Connect the XactTrace sensors only to an input that is electrically isolated fr...

Страница 3: ...an be purchased to interface the locks with most PSG systems that accept the 1 5mm female touchproof connectors Belt Sensor Fitting the XactTrace Belts The belts are intended to be worn over nightclot...

Страница 4: ...gly without being uncomfortably tight Measure the patient s circumference and use the table below as a guideline The belts are single use XactTrace Belt Sizes Full Size Reduced Size cm Inches cm Inche...

Страница 5: ...ector as shown in the figure below The belt should fit snugly without being uncomfortably tight 2 Prepare the abdomen belt in the same manner only this time fit the belt around the patients stomach an...

Страница 6: ...sor module labels are color coded for easy identification and connection 5 Plug the thorax and the abdomen module outputs into the appropriate bipolar inputs on your polygraph The red touch proof plug...

Страница 7: ...Fitting the XactTrace Belts Material Elastic belt W 25 WHITE TERYLENE WITH WIRE UL1571 28 WHITE Cable Length 16 inches 41 cm Thorax 26 inches 66 cm Abdomen or 78 inches 200 cm Thorax Abdomen Material...

Страница 8: ...heric pressures from 7 3 psi to 29 psi Output Specifications RIP Processor Output Signal Maximum signal amplitude 2mV Frequency Range 0 2 to 3 Hz Sensitivity Approximately 50 V mm Storage Proper stora...

Страница 9: ...fects in materials and workmanship for 6 months from the date purchased The sole liability of Embla and our distributors is limited to replacement or repair of the product at the option of Embla with...

Страница 10: ...nditions of sale of Natus Neurology Incorporated or its distributors Natus Neurology Incorporated makes no representations or warranties of any kind whatsoever with respect to this document Natus Neur...

Отзывы: