When assembling a system, the person carrying out the assembly must take into account that other con-
nected equipment which does not comply with the same safety requirements as this product (e.g. PC
and/or printer) may lead to a reduction in the overall safety level of the system. The equipment must com-
ply with IEC 60950.

11

Manufacturer

Natus Medical Denmark ApS
Hoerskaetten 9, 2630 Taastrup
Denmark

+45 45 75 55 55

www.natus.com

11.1

Responsibility of the manufacturer

The manufacturer is to be considered responsible for effects on safety, reliability, and performance of the equipment only
if:

All assembly operations, extensions, re-adjustments, modifications or repairs are carried out by the equipment man-
ufacturer or personnel authorized by the manufacturer.

The electrical installation to which the equipment is connected complies with EN/IEC requirements.

The equipment is used in accordance with the instructions for use.

The manufacturer reserves the right to disclaim all responsibility for the operating safety, reliability and performance of
equipment serviced or repaired by other parties.

22

Otometrics - AURICAL HIT

11 Manufacturer

Содержание Otometrics Aurical HIT

Страница 1: ...AURICAL HIT and the OTOsuite HIT Module User Guide Doc No 7 50 1230 EN 06 Part No 7 50 12300 EN...

Страница 2: ...etrics the Otometrics Icon AURICAL MADSEN HI PRO 2 Otoscan ICS and HORTMANN are registered trademarks of Natus Medical Denmark ApS in the U S A and or other countries Version release date 2019 09 18 2...

Страница 3: ...5 3 Installation 5 4 The test chamber 5 5 Testing hearing instruments 9 6 Maintenance and Calibration 16 7 Other references 17 8 Technical specifications 17 9 Definition of symbols 20 10 Warning notes...

Страница 4: ...ument dispensers and other health care pro fessionals in testing programmable hearing instruments Required qualifications It is assumed that the user has a basic knowledge of how to compare the result...

Страница 5: ...ecessary parts and accessories If your package is incomplete contact your local distributor 3 Installation Place AURICAL HIT on an absolutely stable surface In order to exclude ambient noise and to co...

Страница 6: ...e 8 C Cable groove 8 The AURICAL HIT handle 8 some models only 4 1 The coupler assembly The coupler assembly consists of the following parts A Coupler adapter B Coupler cavity C Coupler microphone 6 O...

Страница 7: ...n 2cc coupler and ear sim ulator The selected coupler type is saved with measurements for later reference Coupler microphone The coupler microphone is located in a coupler bottom piece which must be a...

Страница 8: ...mitters and body worn hearing instruments at a level where the microphone or microphones are approximately centered in relation to the loudspeaker 4 4 The AURICAL HIT handle Note This only applies to...

Страница 9: ...ng instruments 12 Thin tube hearing instruments 13 ITE hearing instruments 14 3 Testing When you have positioned the hearing instrument correctly you can test it using the OTOsuite HIT module as descr...

Страница 10: ...trument the only two important things to remember are Aligning directional microphones along the loudspeaker axis Positioning the reference microphone as close as possible to the front microphone of t...

Страница 11: ...HIT automatically detects the battery simulator Caution When you have connected the battery simulator make sure that it does not touch other metal parts as this may short cir cuit the system 5 4 Coupl...

Страница 12: ...E hearing instruments This procedure applies to any type of standard BTE hearing instruments with traditional earmolds Using the HA 2 adapter and BTE adapter tube 12 Otometrics AURICAL HIT 5 Testing h...

Страница 13: ...the Receiver In the Ear RIE Receiver In the Canal RIC and pre bent tubing Using the HA 1 ITE adapter Note If you place some acoustic putty on the receiver wire this will shift its resonance frequency...

Страница 14: ...ing instrument During telecoil testing AURICAL HIT automatically detects the orientation of the hearing instrument 2 Enable telecoil mode in the hearing instrument 3 Close the lid and start testing 5...

Страница 15: ...tically when you use OTOsuite with Noah together with the fit ting software for the hearing instrument 5 Position the hearing instrument so that it is ready for testing and switch it on 6 If you wish...

Страница 16: ...accommodates any adaptational behavior of the hearing instrument Adaptive directionality often takes 10 to 15 seconds or more before the directionality of the hearing instrument is fully efficient 3 Y...

Страница 17: ...liquids Do not allow moisture inside the unit Moisture inside the unit can damage the instru ment and it may result in a risk of electrical shock to the user or patient Adapters If needed remove any a...

Страница 18: ...ncy range coupler microphone equalized 125 to 200 Hz 3 dB 200 to 5000 Hz 1 dB 5000 to 10000 Hz 3 dB Battery simulator Voltage range 0 to 2 0 V Resolution voltage 0 02 V Accuracy voltage 0 05 V Output...

Страница 19: ...et Warm up time 15 min Standards AURICAL HIT CE marked according to the Low Voltage Directive 2014 35 EU Safety IEC 61010 1 2010 Test standards ANSI S3 22 2009 IEC 60118 7 2005 EMC IEC 61326 1 2013 Ac...

Страница 20: ...ark USB socket for connecting AURICAL HIT to a computer Socket for connecting external coupler microphone Electronic equipment covered by the Directive 2012 19 EU on waste electrical and electronic eq...

Страница 21: ...y used for purposes other than the applications defined in the Intended Use section of this manual 10 The device should be turned off before any connections are established To disconnect the device fr...

Страница 22: ...The manufacturer is to be considered responsible for effects on safety reliability and performance of the equipment only if All assembly operations extensions re adjustments modifications or repairs a...

Отзывы: