background image

3

Location of the Pellet Fire

Installation of the EcoChoice PS35 Freestanding Wood Pellet Burning Heater should be 

undertaken by an experienced installer. Please read the EcoChoice PS35 Owner’s/Installation 

Manual thoroughly before commencing installation as failure to follow the instruction could 

cause damage to the pellet fire or property. 

Positioning the fire:

Generally the EcoChoice PS35 should be installed in a centrally located position within the 

home. When deciding where to position the appliance in your room you need to consider the 

following:

• 

Location of a power source.

• 

The EcoChoice PS35 has a convection fan which blows air in the direction that the fire 

faces, for optimum performance this location should be in a large room centrally located.

• 

The  EcoChoice  PS35  must  be  installed  on  a  non-combustible  surface. This  surface 

must protrude 150mm from the front of the closed pellet fire door.

• 

The  EcoChoice  PS35    has  been  Safety  Tested  to  AS/NZS  2918  using  the  Davins 

manufactured  flue.  Test  Report  ARS  05/1185.  Installation  is  not  exclusive  to  these 

nominated kits, though alternative flue should only be considered following consultation 

with your local council.

• 

Please consult page 2 for the required clearances to combustible material also ensure 

the position of structural elements near the proposed flue.

• 

Because  of  the  positive  pressure  in  the  flue,  sealing  of  all  75mm  stainless  joints  is 

mandatory – use high temperature sealant.  Both inner and outer flue joints must be 

riveted.

• 

Seismic Restraint:  Please view page 6 for requirements.

• 

Warranty:  To validate warranty following installation a copy of the completed Warranty/

Producer’s Statement must be forwarded to: Switch - Fax (03) 341 8057.