D. 

Safety Precautions 

          
Do not operate this equipment for anything other than its intended purpose or for anything other 
than in accordance with the instructions contained in this manual and all other instructions 
accompanying the boiler. It is important to observe safety precautions to protect yourself and others 
from possible injury. Observe all safety labels on the boiler. 

 
All electrical and plumbing should be done by qualified personnel and conform to national, 
state and local electrical, plumbing, fire and building codes.  
 

1.  DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE. Never use chemicals or any 
type of petroleum based product, charcoal starter, lighter fluid, lantern fuel, kerosene or any other 
flammable accelerant to start the fire in the firebox of the boiler. Keep all such liquids well away 
from firebox. 
 
2.  If using antifreeze, use only non-toxic, follow manufacturer’s recommendations on mixing ratio 
and test annually per manufacturer’s specs. Keep containers of antifreeze, which is flammable, well 
away from the boiler. 

 

3.  The use of treated wood (painted, treated, etc.) and any other salvaged material that can emit 
toxic gases into the environment and is corrosive towards the components of the appliance is not 
allowed and voids the warranty. 
 
4.  DANGER! Risk of fire or explosion – DO NOT BURN GARBAGE, GASOLINE, NAPHTHA, 
ENGINE OIL OR OTHER INAPPREPRIATE MATERIALS. Flammable liquids household or yard 
waste can reduce the life of the boiler, will void the warranty and is illegal in most areas. 

 

5.  Pause for 30 seconds between the first latch and the safety latch to allow any combustion gases 
to burn off. Always keep fueling and de-ashing doors closed and maintain all seals in good 
condition. 

 

6.  In the event of a runaway fire, make sure all doors are tightly shut, unplug the control power, 
keep the pump running, make sure the blower damper is closed and keep the water jacket full. 

 

7.  WARNING! Risk of fire – Do not operate with fuel loading door open. Do not store fuel or other 
combustible material within the marked installation clearances. Leaving a small crack or opening 
can cause over-heating in the firebox, boiling the water off, damage of the unit and voiding the 
warranty. Inspect and clean the firebox, ash pan and chimney regularly. 

 

8.  CAUTION! Hot surfaces. Keep children away. Do not touch during operation. Always use proper 
care when installing, operating and maintaining the boiler.  

 

9.  Always wear protective gloves and glasses and be aware that hanging and loose clothing can 
catch fire. 

 

10. All doors and covers must be maintained in place at all times, except during maintenance and 
servicing. 

 

11. Do not modify the boiler or controls. Do not connect this unit to a chimney flue serving another 
appliance. 

 

12. Failure to heed these warning or any additional warnings on the boiler may result in an accident 
causing personal injury and damage and void the warranty. 
 

All installation and operation must follow federal, provincial, state and local codes 

Содержание NCB-175

Страница 1: ...od Boiler Manufactured by Nature s Comfort LLC Made in the USA Full color and French manual available online at Couleur et manuel en fran ais est disponible en ligne www naturescomfortllc com Built Li...

Страница 2: ......

Страница 3: ...you are in need of insulated pex heat exchangers or other parts for your new boiler call your dealer or call us at 877 251 7740 for the lowest prices Boiler water treatment and test required at time...

Страница 4: ......

Страница 5: ...w 16 K InstallingOn AnExistingIndoorBoiler 16 L FillingTheBoilerwithWater 18 M FloatLevel 18 N BleedingAirFromHeatExchangers 18 O Pre conditioningRopeSeals 18 III HeatingDomesticWater PoolsandSpa s A...

Страница 6: ...VAC Water Pump 115 VAC 2A max Chimney 6 inside diameter NCB 175 220 000 BTU 175 gallon water tank 4 000 sq ft 67L x 50W x 85H 1733 pounds NCB 250 300 000 BTU 250 gallon water tank 6 000 sq ft 85L x 5...

Страница 7: ...Flammable liquids household or yard waste can reduce the life of the boiler will void the warranty and is illegal in most areas 5 Pause for 30 seconds between the first latch and the safety latch to...

Страница 8: ...le zone You may install fittings to have ports for up to 4 zones Consult your dealer Additional port setups with pumps are also available from Nature s Comfort when ordering a new unit Single Zone set...

Страница 9: ...ger that must be installed in the existing furnace system If you have a forced air system a water to air heat coil must be installed in the ductwork When air travels through heat is extracted and hot...

Страница 10: ...ces and to the prevailing wind direction 2 Do not locate the boiler within 100 ft of a residence not served by the boiler Be considerate of neighboring residences properties parks etc 3 Do not locate...

Страница 11: ...ed pex pipe for transferring the heated water from the boiler to the home Minimum pipe size permitted is 1 Platinum 3 wrap 4 drain tile Platinum 4 wrap 5 drain tile insulated pipe is available for pur...

Страница 12: ...maximum BTU output A 1 pipe can carry up to 37 more BTUs due to higher water flow The fittings above would need to be changed to accommodate 1 Pex The Armstrong E9 2 pump available from Nature s Comf...

Страница 13: ...ou have a 2 wire system or the thermostat is the advanced computerized type that communicates back and forth between the furnace typically found on heat pump systems Do not use this method if your HVA...

Страница 14: ...Use adhesive backed foam tape used for insulating doors and windows to seal around the frame and foil tape to seal off the opening you make in the plenum heat for the heat exchanger Make sure the fit...

Страница 15: ...Slide the heat exchanger carefully into the plenum to check the fit again Once proper fitting is verified you can seal off the ends of the heat exchanger and the hole you made in the plenum with foil...

Страница 16: ...outdoor boiler to the indoor hydronic system so that the two systems remain isolated see next diagram As shown in the above figure the two systems are totally isolated from each other so that the exis...

Страница 17: ...Page 17 of 32...

Страница 18: ...culated for 1 hour test Nitrite level to assure required 1 000 1 500ppm and add treatment if below this level Submit a water sample to your dealer or Nature s Comfort for official warranty Nitrite tes...

Страница 19: ...iler must first go to the top side port This creates twice the domestic water flow through the sidearm as opposed to coming in at the bottom side port For the fastest recovery install a small circulat...

Страница 20: ...a pool or spa since the chemicals used in a pool spa are destructive to the boiler Pool heat exchangers are available from Nature s Comfort or your dealer For sizing you will need to know the volume...

Страница 21: ...will not dry out season properly until split Hardwoods burn longer than softwoods as they are denser and have more available BTU s Larger pieces burn longer than smaller pieces but take longer to sea...

Страница 22: ...s there are too many variables outside of its control D Power Loss Running On A Generator The controls are designed for the control plug to be used on a generator or vehicle inverter if needed If the...

Страница 23: ...removed to reduce the risk of a chimney fire Smaller more frequent loading and dry seasoned wood will help limit this A small and intense fire is preferable to a large smoldering one to reduce the am...

Страница 24: ...ave as a spare Water Since water quality characteristics greatly vary across the USA some customers get much longer life out of a pump than others Filling a boiler with softened water adding and maint...

Страница 25: ...e rotor To remove the canister first remove the rotor then tap on the bleeder screw to remove the canister from the motor use this procedure for replacing the entire cartridge as well White vinegar or...

Страница 26: ...u should ever have a problem or question refer to this manual or call your dealer If your dealer does not have the information you need request they contact Nature s Comfort and your dealer will be fu...

Страница 27: ...s low in boiler Aqua stat malfunction Not enough demand or warm weather Make sure doors and covers are sealed adjust if necessary Adjust damper Larger pump or pipe reduce of fittings Add water to keep...

Страница 28: ...Page 28 of 32 Copy of Safety Labels...

Страница 29: ...ide Skin 17 Lower Control Jamb Outlet 6 Front Gable Skin 18 Firebox Door Hinge Switch 7 19 Ash Pan Latch Aquastat 8 Upper Side Frame 20 Firebox Door Latch Solenoid 9 Rubber Cap 21 Control Panel Rear C...

Страница 30: ...a water sample must be submitted for nitrite testing when first filled and then annually at the end of a heating season to ensure proper nitrite concentration 1 000 1 500ppm for your warranty to rema...

Страница 31: ...the boiler If you should ever have a problem or question refer to this manual or call your dealer If your dealer does not have the information you need request they contact Nature s Comfort and your...

Страница 32: ...______________________________________ Business and first last name Date of Installation _________________________________ In case of questions Installed By ___________________________________________...

Отзывы: