Electronic pellet burner controller - NPBC-V6T-2
I
NPUTS
AND
OUTPUTS
OF
NPBC-V
6T
-2
Outputs
Inputs
FM
Main fan
RT
Room thermostat
. To this input could
be connected a normally opened or
normally closed contact, with no
additional voltage.
FSG
Fan for the flue gases
PS
Photo sensor
SF
Screw for fuel
RB
Reverse burning sensor
SB
Internal screw
B
Boiler temperature sensor
PH
Heating installation pump
WH
Water heater temperature sensor
PWH Hot water heater pump
PT
pt100 high temperature sensor
IGN
Hot water heater pump
OD
Input for switch for Forced stop with
normally open or normally closed
contact or for vacuum switch
( pressure switch) with normally
closed contact.
FC
Fan for cleaning or linear actuator
forward
LED
AUX Linear actuator backward (
Option
)
ACF
Analogue fan output
(Option)
D
O
NOT
USE
THE
EXECUTIVE
MODULE
WITHOUT
IT
BEING
INSTALLED
IN
A
BURNER
OR
EXTERNAL
BOX
,
SO
THAT
NO
EXPOSED
CONDUCTIVE
ELEMENTS
ARE
ACCESSIBLE
. T
HERE
IS
A
RISK
OF
ELECTRIC
SHOCK
WHEN
TOUCHING
SOME
ELEMENTS
IN
THE
EXECUTIVE
MODULE
.
F
OR
BETTER
OPERATION
OF
T
OUCH
DISPLAY
,
THE
GROUND
WIRE
OF
THE
POWER
SUPPLY
MUST
BE
CONNECTED
TO
THE
PE
INPUT
OF
THE
POWER
TERMINAL
.
User Manual / ver. 1.2
http://www.naturela-bg.com/en/
page 7 of 41