Page
15
capacity in %
Flashing
amber
Same as
above
Same as above and utility AC power is just
detected and AC output will switch to utility
power within a few seconds
Solid red
“E01-E11”
Error on unit is detected. AC output is
disconnected. See Trouble shooting
section
Full
Automatic
Silent
In1,Ch1,
Al0
Same as “Full Automatic Mode” but with audio alarm disabled. The unit
fault protection features remain active and will shut down without audio
warning when fault occurs.
Auto
backup
with
internal
AC
charger
disable
In1, Ch0,
Al1
Solid
green
“Ful”
AC output is supplied by utility AC power.
Internal battery is fully charged
“XX.X” in %
AC output is supplied by utility AC power.
Internal battery is not fully charged. Display
show battery capacity
Solid
amber
Flash between
Output Power
“X.XX” in kW &
“XX” battery
capacity in %
AC output power is supplied by the inverter
through internal battery and/or Nature
Power solar panel or another external solar
panel or charger.
Flashing
amber
Same as
above
Same as above and utility AC power is just
detected and AC Output will switch to utility
power within a few seconds
Solid red
“E01-E11”
Error on unit is detected. AC output is
disconnected. See Trouble Shooting
section
Auto
backup
with
internal
AC
charger
and alarm
disable
In1, Ch0,
Al0
Same as “Auto backup with AC charger disable mode” but with audio
alarm disabled. The unit fault protection features remains active and will
shut down without audio warning when fault occurs.
Backup
priority
In2,Ch0,
Al1
Solid
amber
Flash between
Output Power
“X.XX” in kW &
battery
capacity “XX”
in %
AC output power is supplied by the inverter
through internal battery and/or solar power
Solid
“XX” in (%)
AC output is supplied by utility AC power