![Nature Power 40400 Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/nature-power/40400/40400_owners-manual_710885012.webp)
Page
12
In2
Ch0
AL1
Backup
Priority
Unit will provide output using battery and solar power as
higher priority.
AC output will only switch to utility mode when battery is
low and available.
Audio alarm is enabled and will sound when any warning
or fault occurs
Note: Only use this mode when there is sufficient solar
power to power up the load.
In2
Ch0
AL0
Backup
Priority with
Alarm
Disable
Same as “Backup priority mode‟ but with alarm disabled.
Audio alarm will not sound when any warning or fault
occurs. The unit fault protection features remain active
and will shut down without audio warning when fault
occurs.
In0
Ch1
AL1
Backup
Disable
AC output is provided by AC utility when utility is available
Internal battery is automatically charged by the 5A
charger
Inverter is disabled and no backup power occurs when
AC utility is not available.
Audio alarm is enabled and will sound when any warning
or fault occurs
In0
Ch1
AL0
Backup &
Alarm
Disable
Same
as “Backup disable mode” but with alarm disabled.
Audio alarm will not sound when any warning or fault
occurs. The unit fault protection features remain active
and will shut down without audio warning when fault
occurs.
In0
Ch0
AL1
Backup &
Charger
Disable
AC output is from utility AC power. No AC output when
utility AC is not available.
In0
Ch0
AL0
Backup,
Charger &
Alarm
Disable
AC output is from utility AC power. No AC output when
utility AC is not available.
Unit Display Label as shown