STEP 5: INSTALL THE COMPOST CHAMBER
A brush seal is supplied for the ‘In-service’ lid and acts as a seal to prevent any odour emitting from the
chamber. Remove the adhesive cover and place the brush seal on the inside surface of the lid as shown
below.
1. Add 50mm depth of bulking agent (not
included in package) to the chamber to create
a bed.
6. Finally, attach the bungee loops as shown.
2. Slide the ‘In-service’ compost chamber lid
(with pre-cut hole) up onto the waste chute
from underneath.
3. Place the chamber underneath the lid.
4. Lower the lid onto the chamber.
5. Rotate the lid to lock the catch plates onto the
pins.
Waste chute
Pins
Lid
Chamber