16
Installation and Maintenance Manual
Remote Chiller Model Installation- Connection of the Still Water Tubing.
1.
Insert the 5/16” O.D. tubing into the tubing insulation provided.
2.
Connect the 5/16” O.D. tubing to the right elbow quick connect
fi
tting on the front of
the
unit.
3.
Connect the other end of the tubing to the 5/16” Union Fitting on the right side of
the Dispense Tower. Note: This
fi
tting may be a 1/4” x 5/16” reducing
fi
tting or a
5/16”
union
fi
tting depending on the Dispense Tower model.
Remote Chiller Model- Connection of CO
2
gas and Water Supply Line.
1.
Connect the 1/4” O.D. CO
2
tube from the CO
2
Cylinder Pressure Regulator to the
1/4”
elbow
fi
tting at the rear of the unit.
2.
Connect the 3/8” O.D. tubing from the Filter Set into the 3/8” elbow
fi
tting at the rear
of the unit.
3.
IMPORTANT: INSTALL LOCKING CLIPS TO ALL PUSH TYPE FITTINGS.