Page 50
4310114
DOWNLOAD DATA TO A PDCD
1.
Connect your portable data collection device (PDCD) per its operating
instructions.
2.
Press
. Data is downloaded into your PDCD.
NOTE
Depending upon the clearing data upon download setting, data
may be cleared after the download is complete.
3.
CONTINUE.
VIEW DIAGNOSTIC MESSAGES
1.
Press
. The display shows any of the following diagnostic
messages, depending upon any fault(s) present:
NO ERRORS
None of the following errors are detected:
KEYPAD XY
KEY(S) X, Y STUCK.
ROM ERROR
Error in the programming EPROM. MACHINE WILL NOT
OPERATE.
RAM ERROR
One or more of the configuration settings may be incorrect.
Check the machine settings (time of day, product dividers, pric-
ing, etc).
1. If the problem is corrected, the
RAM ERROR
message can be
cleared by pressing
once.
NOTE: If the source of the error is not resolved, pressing
will clear the error code, but will not resolve the problem.
2. If you cannot find the problem, you can initialize your RAM by
performing the following procedure:
Press AND HOLD
until two beeps are heard and the
display shows
FINISHED
. Reconfigure the merchandiser.
IMPORTANT NOTE: Initializing RAM will erase all data and set-
tings (price, time, monetary options, messages, etc). Be sure
you have recorded this information and are ready to reprogram
the machine from factory default settings before continuing.