5314 Blower |
11
www.natvac.com | 800.253.5500
SPECIFICATIONS
Operating Environment
The 5314 blower is designed to move atmospheric air. Do not use to move
explosive or corrosive gasses or operate the blower in an area with explosive
gases. Any materials in the intake air must be filtered and separated from
the air by means of an intake filter, moisture trap and/or a cyclonic filter.
The ballast inlet must be positioned and protected from ingesting debris,
fluid or explosive gases.
Operating Limits
The blower must be operated within all limits at all times. This typically
means the blower performance is limited by the exhaust temperature and
temperature rise over ambient for the blower.
Size
RPM
Inlet
Vac
(in Hg)
Press.
Rise†
(psig)
Exh.
Press.
(psig)
Inlet
Temp
(
°
F)
Exh.
Temp
(
°
F)
Temp
Rise‡
(
°
F)
Ballast
Inlet
Temp
(
°
F)
Max
Min
Max
Max
Max
-
Max
Max
-
5314
3600
900
FULL
VAC
14
10
*
380
260
*
*Exhaust temp and temp rise limited, †Pressure rise is from inlet to outlet, ‡Temperature rise is
exhaust minus ambient temperature surrounding blower (note if enclosed)