background image

26

  |  5314 Blower 

www.natvac.com  |  800.253.5500

Recommended Oils for Blower (Synthetic Only)

Ambient Temp

°

F (

°

C)

Type

Viscosity 

Pour 

Point

Color

Above 90

°

F

 

(32

°

C)

Summit Syngear SH-7320

Mobile SHC 632

ISO 320

-40 (-40)

-40 (-40)

Clear

Orange

32

°

 to 90

° 

(0

°

 

to 32

°

)

Summit Syngear SH-7220

Mobil SHC 630 

ISO 220

-45 (-43)

-41 (-42)

Clear

Orange

0

°

 to 32

°

 (-18

°

 

to 0

°)

Summit Syngear SH-7150

Mobile SHC 629

ISO 150

-60 (-51)

-45 (-43)

Clear

Orange

Below 0

°

 (-18

°

)

Summit Syngear SH-7100

Mobil SHC 627

ISO 100

-60 (-51)

-45 (-43)

Clear

Orange

*Ambient temp is the temperature of the space where the blower is located or enclosed. 

Right Angle Gearbox Lubricant

Size

Capacity (oz) Manufacturer

Grade

500 Series

28

Mobil

Mobilube SHC 75W-90

600 Series

80-90

Mobil

Mobilube SHC 75W-90

· 

Dispose of used oil according to local regulations

Rebuilding

Rebuilding is beyond the scope of this owner’s manual and should be  

performed only by trained technicians.  Consult an authorized distributor or 

NVE to arrange rebuilding of the blower.

Содержание 5314

Страница 1: ...NationalVacuumEquipment Owner s Manual Operating Instructions Model 5314 Blower MADE IN USA Visit our web site to download brochures and other technical information...

Страница 2: ...2 5314 Blower www natvac com 800 253 5500...

Страница 3: ...nc Revision A No part of this manual may be reproduced without the written permission of National Vacuum Equipment Inc 5314 Blower Owner s Record Date of Purchase _________________________ Purchased f...

Страница 4: ...lower Construction 10 Location of Serial Number 10 Specifications 11 Operating Environment 11 Operating Limits 11 Performance Reference Only 12 Dimensions 13 Air Flow Control 13 Noise Level 13 Limitat...

Страница 5: ...Hoses 20 Pressure Relief Valve 20 Vacuum Relief Valve 20 Check Valves 21 Primary Shutoff 21 Secondary Shutoff Moisture Trap 21 Bag House 21 Operation 22 Initial Start Up 22 Operating 23 Stopping the B...

Страница 6: ...is We are a one stop shop for manu facturers and distributors of vacuum equipment Our History National Vacuum Equipment Inc was founded in 1980 by Bruce Luoma The Company started as a retailer of vacu...

Страница 7: ...nded We do not recommend our product for particular uses or applications 4 Damage caused by improper use or lack of proper maintenance is not warrantable 5 Manufacturer s liability under this or any o...

Страница 8: ...must receive a Return Material Authorization RMA before returning product All serial numbered products must retain the NVE serial number tag to be qualified for warranty Product must be returned to N...

Страница 9: ...on The air enters the intake under vacuum or at atmospheric pressure As the rotors rotate a fixed volume of air is moved along the wall of the cylinder towards the exhaust where the pressure and tempe...

Страница 10: ...Blower Construction Location of Serial Number Each blower should have a brass colored tag with an embossed serial num ber In addition the serial number and blower direction as assembled at the factor...

Страница 11: ...ned and protected from ingesting debris fluid or explosive gases Operating Limits The blower must be operated within all limits at all times This typically means the blower performance is limited by t...

Страница 12: ...5 474 382 257 62 546 2500 HP 2 5 23 8 37 9 45 0 52 1 59 2 50 6 ACFM 1102 835 694 602 478 283 767 3000 HP 3 0 28 5 45 5 54 0 62 5 71 0 79 5 60 7 ACFM 1323 1056 915 823 698 503 B O 987 3500 HP 3 5 33 3...

Страница 13: ...can be adjusted by changing the speed of the blower This can be accomplished by changing the PTO ratio gearbox ratio belt drive pulley diameters or engine speed Noise Level The noise level of the blo...

Страница 14: ...ge Operating blower below minimum speed Seizure of blower damage to blower and ejection of parts Exceeding the maximum pressure rise from blower inlet to outlet Overheat of Blower Fire Seizure of blow...

Страница 15: ...ge has occurred during shipping In the event damage has occurred first file a claim with the carrier and then contact NVE for assistance Keep all intake exhaust and ballast ports covered to prevent ac...

Страница 16: ...e in storage rotate the shaft three to four revolutions every two weeks to keep gears coated in oil Before installing a blower that has been stored for any length of time remove the intake and exhaust...

Страница 17: ...esult in an inertial mismatch excess torsional vibrations at low RPM s and blower lobe contact For more information Diesel torsional vibrations see the technical report by LoveJoy titled New Twists to...

Страница 18: ...lower bearings Use a narrow hub sheave and insure that the inner hub face is not more than 1 4 from the face of the gearbox Be sure to also use an adjustable belt tensioning system to allow compensati...

Страница 19: ...a Blower Torque Guide Bul letin HY25 0075 B1 US available at www parker com Improper use of Hot Shift i e clutch type constant mesh PTO s can result in severe damage to the blower driveline and blower...

Страница 20: ...he blower in the pressure mode a four way valve will be required The 4 way valve size should match the hose size used in the application Pressure Relief Valve If the blower is intended to be used in p...

Страница 21: ...off A primary shutoff is to be used with the blower as a first line of defense to prevent liquid from entering the blower It is critical that an appropriately sized primary shut off is used Contact NV...

Страница 22: ...tional oil is required see the maintenance section for details Verify the blower is set up to spin the correct direction especially when using a gearbox Verify all guards are in place Insure personnel...

Страница 23: ...the event of a lock up of the blower because the jaw or sleeve can handle more torque before giving way If hydraulically driving the blower allow the hydraulic fluid to warm up before operating the bl...

Страница 24: ...e beginning work to prevent burns MAINTENANCE SCHEDULE CHECK PARAMETER FREQUENCY COM MENTS H D W M VISUAL Pressure 1 Blower Running Temperature 1 Load Absorbed Power 1 Noise 1 LUBRICATION Oil Level 1...

Страница 25: ...n the blower is after 500 hours of operation per the maintenance table Size Blower Oil Capacity Do Not Overfill Drive Side Oz Liters Non Drive Side Oz Liters Total 4310 18 53 8 24 26 77 747 18 53 8 24...

Страница 26: ...5 43 Clear Orange Below 0 18 Summit Syngear SH 7100 Mobil SHC 627 ISO 100 60 51 45 43 Clear Orange Ambient temp is the temperature of the space where the blower is located or enclosed Right Angle Gear...

Страница 27: ...hows only clean water 5 With the blower running spray a small amount of penetrating oil into the intake and run until no liquid comes out the exhaust DO NOT SPRAY OIL INTO THE BLOWER WITH THE SILENCER...

Страница 28: ...ID 5314 NOTE 3 4 23 4 150 630 5314 OD SEAL SLEEVE 5314 NOTE 2 24 4 150 631 5314 SEAL SLINGER 5314 MACHINED NOTE 5 25 1 150 633 001 SHAFT SPACER DRIVE SHORT 5314 26 1 150 633 002 SHAFT SPACER IDLER LON...

Страница 29: ...14 END COVER GEAR 5314 MACH 21 1 150 629 001 SEAL SLEEVE 5314 22 4 150 629 5314 SEAL SLEEVE ID 5314 23 4 150 630 5314 OD SEAL SLEEVE 5314 24 4 150 631 5314 SEAL SLINGER 5314 MACHINED 25 1 150 633 001...

Страница 30: ...Two places XX 01 Three places XXX 005 Angles 1 Fractional X X 1 16 All machined surfaces 125 RMS max Remove all burrs and sharp edges CAD drawing NO manual changes All dimensions in inches unless spe...

Страница 31: ...8 VITON 2 2 150 616 5314 GASKET BALLAST MANIFOLD 5314 3 1 150 650 012 BALLAST MANIFOLD LH 5314 4 1 150 650 013 BALLAST MANIFOLD RH 5314 5 1 150 650 014 BALLAST TEE 5314 MACH 6 24 LW 5 6 LOCK WASHER 5...

Страница 32: ...s expected STOP THE BLOWER TO PREVENT DAMAGE E F H Outlet temperature is not what s expected STOP THE BLOWER TO PREVENT DAMAGE D E F G H J K Prime mover engine or motor is laboring exces sively when d...

Страница 33: ...hin specification and adjust accordingly L Bearings worn Have blower rebuilt M Oil level too high Check required oil level in each tank and remover oil as necessary N Coupler or belts not aligned Chec...

Страница 34: ...34 5314 Blower www natvac com 800 253 5500...

Страница 35: ...5314 Blower 35 www natvac com 800 253 5500...

Страница 36: ...36 5314 Blower www natvac com 800 253 5500 P O Box 685 Traverse City MI 49685 USA 231 941 0215 Phone 231 941 2354 Fax National Vacuum Equipment Inc...

Отзывы: