Precautions for Use
Names of Parts
Specifications (MODEL: 7019)
Directions for Use
4
7
5
3
6
9
10
12
2
8
1
DANGER
WARNING
CAUTION
CAUTION
DANGER
WARNING
5A
Operating temperature
Operating voltage
DC19.2V
Approx. 28liters (7 Gallons) at Water
Approx. 850 ~ 1245mm (33.5”~ 49”)
Approx. 2m (6.6ft)
Delivery volume
Suction pipe length
Discharge hose length
Applicable liquids
Fuse
+5˚C ~ 40˚C (41˚F ~ 104˚F)
Diesel, DEF(AdBlue), Water, Kerosene, Antifreeze, Windshield washer fluid,
Mild detergents, Agricultural chemicals, Light oils.
Toggle Switch
Nozzle holder
Battery adapter
Nozzle
Drum bung adapter
Suction pipe
Discharge hose
Operating lamp(LED)
Adjustment nut
11
If the directions of this sign are not
followed, fatal accidents can happen and
the user may die or get seriously injured.
Do not use for flammable liquids or
concentrated acids.
Be cautious. This pump does not
have an explosion proof motor.
Do not use near the flammable
materials such as gasoline, gas, etc.
Only use on applicable liquids
written on the specifications.
These instructions are to ensure the product is used correctly, safely, and to prevent any possible risk or damage to the user
and/or others people. Our company shall not take any responsibility for any failure of product, malfunction and damages
caused by improper use by the user or third parties.
Make sure the pump is tightly
secured to the drum(tank) before
turning the pump on.
Do not refuel directly while the
vehicle or equipment is turned on.
Do not leave the pump unattended.
Make sure to use the pump on even
surface.
Do not allow children to operate the
product without adult supervision.
After using the pump, do not keep it
on its side or upside down.
Make sure to remove any left-over liquid
in the discharge hose after each use.
Do not alter or disassemble the ump.
Do not run the pump ‘dry’ or let the
pump idle without transferring.
Make sure to turn off the power after
using the pump.
Do not shock the pump.
Do not use deteriorated or
contaminated liquids and fuels.
Do not place the pump in a wet area.
Do not use this pump for hot liquids
above 40°C (104°F ).
The included 19.2V Ni-Cade battery
charged with about 80% from the
factory and need to discharge
completely each time before
recharging to get it’s full capability.
Recharging before the battery
completely discharged will shorten its
charge and cannot be returned to its
original storage capacity.
If the directions of this sign are not
followed, accidents can happen or
the user can get injured.
If the directions of this sign are not
followed, the product can get damaged
or the user can get injured.
Adjust the length of the suction pipe
to fit the drum (tank).
Insert the suction pipe into the
drum (tank).
Tighten the drum bung adapter.
Connect the 19.2V battery into the
battery adapter.
Place the nozzle into the receiving
container to transfer liquid.
Toggle switch ON(Up).
Pull the nozzle lever and start
supplying the liquid.
Release the lever when the liquid
supply is completed.
Toggle switch OFF(Down).
Pulling the lever of the nozzle,
lift it up.
Let the left-over liquid in the hose
flow back into the drum (tank).
Insert the nozzle in the nozzle holder
for storage.
2
3
Charger
19.2V Ni-Cade battery
Buttress adapter