background image

Chapter 2

Setup

Getting Started with Your VXIpc 800/700

2-4

©

 National Instruments Corporation

manager (such as 

EMM386.EXE

), you must exclude the region 

assigned to your VXIpc 800/700. This region may shift if you 
insert any expansion boards into the PCI expansion slot.

8.

Execute the Resource Manager utility, 

RESMAN

,

 to configure your 

VXI system. 

VME Users

RESMAN

 identifies and configures the VXI devices. 

RESMAN

 does not 

configure VME devices. The VME specification does not define the 
initialization and configuration procedures that the VXI specification 
requires. 

However, it is recommended that you enter the information about your 
VME devices into the 

VXIedit

 or 

VXItedit

 utility. 

RESMAN

 can then 

use this information to properly configure the various device-specific 
VME address spaces and VME interrupt lines. For more information 
on configuring non-VXI devices in your VXI system, refer to the 
description of the Non-VXI Device Configuration Editor in Chapter 3
VXI Resource Editor: VXIedit
, of the NI-VXI Graphical Utilities 
Reference Manual
.

Device Interaction

After 

RESMAN

 has detected and configured all VXI/VME devices, you 

can view specific information on each device in your system by using 
the 

VXIedit

 or 

VXItedit

 utilities. These utilities include a Resource 

Manager Display, which contains a description for each device, 
including each VXI device’s logical address.

You can interact with your VXI/VME devices by using the 

VIC

 or 

VICtext

 utilities. With these utilities, you can interactively control 

your VXI/VME devices without having to use a conventional 
programming language, LabVIEW, or LabWindows/CVI. 

Try the following in 

VIC

 or 

VICtext

:

At the prompt, type:

help vxiinreg

Содержание VXIpc 800 Series

Страница 1: ...rutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In sto...

Страница 2: ...etting Started with Your VXIpc 800 700 Series Getting Started with Your VXIpc 800 700 April 1997 Edition Part Number 321123E 01 Copyright 1996 1997 National Instruments Corporation All Rights Reserved...

Страница 3: ...mark 45 76 26 00 Finland 09 527 2321 France 01 48 14 24 24 Germany 089 741 31 30 Hong Kong 2645 3186 Israel 03 5734815 Italy 02 413091 Japan 03 5472 2970 Korea 02 596 7456 Mexico 5 520 2635 Netherland...

Страница 4: ...SS OF DATA PROFITS USE OF PRODUCTS OR INCIDENTAL OR CONSEQUENTIAL DAMAGES EVEN IF ADVISED OF THE POSSIBILITY THEREOF This limitation of the liability of National Instruments will apply regardless of t...

Страница 5: ...l area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Notices to User Changes or modifications not expressly approved by...

Страница 6: ...tion ix Customer Communication x Chapter 1 Introduction What You Need to Get Started 1 1 Hardware Description 1 1 Software Description 1 2 Software Configurations 1 3 Optional Software 1 3 Files and D...

Страница 7: ...ies Hardware Default Settings 3 1 Table 3 2 VXIpc 700 Series Hardware Default Settings 3 2 Table 3 3 Logical Address Configuration Editor Default Settings 3 3 Table 3 4 Device Configuration Editor Def...

Страница 8: ...irectory structure on your hard drive Chapter 2 Setup contains basic instructions for setting up the VXIpc 800 700 and the NI VXI software Chapter 3 Default Settings summarizes the hardware and softwa...

Страница 9: ...names of disk drives paths directories programs subprograms subroutines device names functions variables filenames and extensions VXIpc 700 Series The terms VXIpc 700 Series and VXIpc 700 refer to a s...

Страница 10: ...epts of VXI and prepares you for detailed explanations of the NI VXI functions Study the descriptions of each function given in the NI VXI Programmer Reference Manual to fully understand the purpose a...

Страница 11: ...your comments on our products and manuals We are interested in the applications you develop with our products and we want to help if you have problems with them To make it easy for you to contact us...

Страница 12: ...eries Monitor with VGA or better resolution NI VXI software media for the VXIpc 800 700 Series The NI VXI software is already installed on your VXIpc 800 700 computer It is also included on disk in th...

Страница 13: ...ware kit gives you accessibility to the industry standard NI 488 2 software for controlling external GPIB instruments through the GPIB port on the front panel or through a PCMCIA GPIB card on models t...

Страница 14: ...can run only 32 bit applications with this driver You cannot use this driver in conjunction with either NI VXI for DOS Windows 3 1 or the NI VXI Upgrade for Windows 95 to run 16 bit applications Appl...

Страница 15: ...l in Adobe Acrobat format To access any of these manuals change your directory to c images manuals and list the contents of that directory You will see several directories one corresponding to each pe...

Страница 16: ...tions vary from peripheral to peripheral Because the naming conventions may not be completely straightforward National Instruments provides a text file named drivers txt in the images directory The dr...

Страница 17: ...guration please refer to the VXIpc 800 700 Series User Manual for information about the hardware or to the NI VXI Software Manual for the VXIpc 800 700 Series for information about the NI VXI software...

Страница 18: ...are Installation in the NI VXI Software Manual for the VXIpc 800 700 Series Windows Users At Windows 95 NT 3 x startup you are prompted to insert a disk to configure the system for LabVIEW or LabWindo...

Страница 19: ...sed section of the Upper Memory region usually 0xC800 to 0xE800 Notice that this memory cannot be used by another device such as a plug in card or memory manager such as EMM386 EXE This placement is v...

Страница 20: ...the various device specific VME address spaces and VME interrupt lines For more information on configuring non VXI devices in your VXI system refer to the description of the Non VXI Device Configurati...

Страница 21: ...w want to read the configuration registers from other VXI devices in your system using the command vxiinreg This command accesses only the upper 16 KB of A16 space Try reading the registers from one o...

Страница 22: ...r kit Refer to the VXIpc 800 700 Series User Manual for more detailed information about the hardware default settings and options The NI VXI Software Manual for the VXIpc 800 700 Series contains more...

Страница 23: ...Series Hardware Default Settings Hardware Component Default Setting W1 Slot detection Automatically detect slot W3 CMOS Clear CMOS not cleared W6 Ethernet EEPROM Enabled Do not alter this setting W7 M...

Страница 24: ...ared RAM Size 0 KB Shared RAM Pool 0 KB Lower Half Window Byte Swapping Disabled non swapped Upper Half Window Byte Swapping Disabled non swapped Map Upper and Lower Halves to Same Address Disabled Re...

Страница 25: ...try Protocol Enabled Automatic VXI Slave Cycle Retry Enabled on the VXIpc 800 Series Disabled on the VXIpc 700 Series A24 A32 Slave Write Posting Disabled VXI Transfer Limit 256 Arbiter Type Priority...

Страница 26: ...ce A24 Requested Memory 16 KB A16 Write Posting Disabled A24 A32 Write Posting Disabled Interlocked Mode Disabled VXI VME System Controller Auto VXI VME Bus Timeout Value 125 s VXI VME Auto Retry Disa...

Страница 27: ...quester Disabled MXI CLK10 Signal Direction Set by hardware switch VXI MXI 2 only Assumes no DRAM is installed If DRAM is installed the Address Space would be A32 and Requested Memory would match the...

Страница 28: ...se systems does not answer your questions we offer fax and telephone support through our technical support centers which are staffed by applications engineers Electronic Services National Instruments...

Страница 29: ...urce from which you purchased your software to obtain support Telephone Fax Australia 03 9879 5166 03 9879 6277 Austria 0662 45 79 90 0 0662 45 79 90 19 Belgium 02 757 00 20 02 757 03 11 Canada Ontari...

Страница 30: ...______________________________________________ _______________________________________________________________________________ National Instruments hardware product model ________________ Revision ___...

Страница 31: ...__________________________ W2 Setting CMOS ____________________________________________________________ W4 Setting LPT1 DMA ________________________________________________________ W13 Setting Slot 0...

Страница 32: ...________________________________ VXI Shared RAM Size _____________________________________________________________ Shared RAM Pool_________________________________________________________________ Byte...

Страница 33: ...pace ________________________________________________________________ Requested Memory ____________________________________________________________ A16 Write Posting __________________________________...

Страница 34: ...ion ___________________________________________________________ Operating system mode ____________________________________________________________ Programming language ________________________________...

Страница 35: ..._____________________________________________________________ _______________________________________________________________________________ __________________________________________________________...

Страница 36: ...address space equivalent to the VME 16 MB standard address space A32 space VXIbus address space equivalent to the VME 4 GB extended address space address Character code that identifies a specific loca...

Страница 37: ...f bused connectors called J1 J2 and J3 BERR Bus error signal BIOS Basic Input Output System BIOS functions are the fundamental level of any PC or compatible computer BIOS functions embody the basic op...

Страница 38: ...e device type model manufacturer address space and memory requirements In order to support automatic system and memory configuration the VXIbus specification requires that all VXIbus devices have a se...

Страница 39: ...use of the bus G GPIB General Purpose Interface Bus IEEE 488 H hex hexadecimal the numbering system with base 16 using the digits 0 to 9 and letters A to F Hz hertz cycles per second I IEEE Institute...

Страница 40: ...Device message based device An intelligent device that implements the defined VXIbus registers and communication protocols These devices are able to use Word Serial Protocol to communicate with one a...

Страница 41: ...me of the National Instruments Resource Manager in NI VXI bus interface software See Resource Manager Resource Manager A message based Commander located at Logical Address 0 which provides configurati...

Страница 42: ...Either TTL or ECL lines used for intermodule communication TTL Transistor Transistor Logic U user window A region of address space reserved by the VXIpc 800 700 Series for use via the NI VXI low level...

Страница 43: ...tion generated by the Resource Manager VXIinit A program in the NI VXI bus interface software package that initializes the board interrupts shared RAM VXI register configurations and bus configuration...

Страница 44: ...dware default settings table 3 1 to 3 2 Logical Address Configuration Editor table 3 3 device settings viewing 2 4 to 2 5 device type 3 3 directories on hard drive 1 4 to 1 5 documentation conventions...

Страница 45: ...2 NI VXI software configurations 1 3 DOS Windows 3 1 1 3 Upgrade for Windows 95 1 3 Windows 95 1 3 Windows NT 1 3 description 1 2 installation DOS 2 3 Windows 95 NT 3 1 2 2 Non VXI Device Configuratio...

Страница 46: ...I shared RAM size 3 3 VXI transfer limit 3 4 VXIbus system controller 2 1 VXIedit VXIedit utility DOS setup 2 3 Resource Manager Display 2 4 to 2 5 VME devices 2 4 VXIinit utility DOS setup 2 3 Window...

Страница 47: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Отзывы: