© National Instruments Corporation
5
VXI-1000 Rackmount Adapter Kit Installation Guide
Step 4. Install the Chassis Track Section
Remove the chassis track sections from the shipping carton. Notice that there are right and left
sections. Properly orient and mount the right chassis section to the adjustable mounting bracket,
using four of the 10-32 x 5/16 inch pan head screws. Repeat this procedure to install the left
chassis section.
Step 5. Adjust the Mounting Bracket for Recessed Mounting
The adjustable mounting bracket is shipped from the factory in the flush mount position. For
recessed mounting, loosen the eight pan head screws on each bracket and extend the brackets as
required (see Figure 2). Be sure to retighten the screws.
Step 6. Install the Front Cover Panel (Recessed Mount Only)
The cover panel gives a finished appearance and protects instrument modules and cabling. To
accommodate the front panel installation, the mainframe must be recessed (see step 5) with
adequate clearance between the cover panel and the instrument cables. The front panel attaches
to the adjustable bracket assemblies with two L brackets, as shown in Figure 3. Secure each L
bracket to bracket assemblies using two 8-32 pan head screws. Secure the front cover to the L
brackets with 1/4 turn fasteners.
"L" Brackets
Figure 3. L Bracket Installation (Front View)