background image

 

National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. 
Refer to the 

Terms of Use

 section on 

ni.com/legal

 for more information about National 

Instruments trademarks. Other product and company names mentioned herein are trademarks or trade 
names of their respective companies. For patents covering National Instruments products, refer to the 
appropriate location: 

Help»Patents

 in your software, the 

patents.txt

 file on your CD, or 

ni.com/patents

.

© 2007 National Instruments Corporation. All rights reserved.

372306B-01

Dec07

Where to Go for Support

The National Instruments Web site is your complete resource for technical 
support. At 

ni.com/support

 you have access to everything from 

troubleshooting and application development self-help resources to email 
and phone assistance from NI Application Engineers.

National Instruments corporate headquarters is located at 
11500 North Mopac Expressway, Austin, Texas, 78759-3504. 
National Instruments also has offices located around the world to help 
address your support needs. For telephone support in the United States, 
create your service request at 

ni.com/support

 and follow the calling 

instructions or dial 512 795 8248. For telephone support outside the United 
States, contact your local branch office: 

Australia 1800 300 800, Austria 43 662 457990-0, 
Belgium 32 (0) 2 757 0020, Brazil 55 11 3262 3599, 
Canada 800 433 3488, China 86 21 5050 9800, 
Czech Republic 420 224 235 774, Denmark 45 45 76 26 00, 
Finland 358 (0) 9 725 72511, France 01 57 66 24 24, 
Germany 49 89 7413130, India 91 80 41190000, Israel 972 3 6393737, 
Italy 39 02 41309277, Japan 0120-527196, Korea 82 02 3451 3400, 
Lebanon 961 (0) 1 33 28 28, Malaysia 1800 887710, 
Mexico 01 800 010 0793, Netherlands 31 (0) 348 433 466, 
New Zealand 0800 553 322, Norway 47 (0) 66 90 76 60, 
Poland 48 22 3390150, Portugal 351 210 311 210, Russia 7 495 783 6851, 
Singapore 1800 226 5886, Slovenia 386 3 425 42 00, 
South Africa 27 0 11 805 8197, Spain 34 91 640 0085, 
Sweden 46 (0) 8 587 895 00, Switzerland 41 56 2005151, 
Taiwan 886 02 2377 2222, Thailand 662 278 6777, 
Turkey 90 212 279 3031, United Kingdom 44 (0) 1635 52354

Содержание USB-9237

Страница 1: ...ations The NI USB 9237 provides a USB interface for four channels of 24 bit half full bridge analog input Introduction The NI USB 9237 consists of two components an NI 9237 module and an NI USB 9162 c...

Страница 2: ...mited Refer to the Specifications section for more details Hot Surface This icon denotes that the component may be hot Touching this component may result in bodily injury Caution Do not disconnect I O...

Страница 3: ...ming environments Select Start All Programs National Instruments NI DAQ NI DAQmx Help LabVIEW If you are a new user use the Getting Started with LabVIEW manual to familiarize yourself with the LabVIEW...

Страница 4: ...NET you can interactively create channels and tasks by launching the DAQ Assistant from MAX or from within Visual Studio NET You can generate the configuration code based on your task or channel in Me...

Страница 5: ...dio NET documentation To view the NI DAQmx NET documentation go to Start Programs National Instruments NI DAQ NI DAQmx NET Reference Help Expand NI Measurement Studio Help NI Measurement Studio NET Cl...

Страница 6: ...stallation instructions that accompany your software Example Programs The NI DAQmx CD contains example programs that you can use to get started programming with the NI USB 9237 Refer to the NI DAQmx f...

Страница 7: ...th the carrier as shown in Figure 3 Figure 3 Module Installation 4 Squeeze the latches and insert the NI 9237 module into the USB 9162 carrier 5 Press firmly on the connector side of the NI 9237 modul...

Страница 8: ...ormation LED Indicator The NI USB 9237 device has a green LED next to the USB connector The LED indicator indicates device status as listed in Table 1 When the device is connected to a USB port the LE...

Страница 9: ...can use to connect an external excitation voltage source to the module Table 2 lists the connections between an external excitation voltage source and the NI USB 9237 Note For a list of accessories a...

Страница 10: ...e 2 Terminal Assignments RJ 50 10p10c Modular Plug and Receptacle Pin Numbers RJ 50 Pin RJ 45 Pin Signal Name Signal Description 1 SC Shunt calibration 2 1 AI Positive input signal 3 2 AI Negative inp...

Страница 11: ...quarter bridge with the NI USB 9237 if you either add a resistor externally to create a half bridge or use the NI 9944 or NI 9945 Quarter Bridge Completion Accessory Visit ni com and search for the NI...

Страница 12: ...alibration Remote Sensing Remote sensing continuously and automatically corrects for errors in excitation leads and generally is most appropriate for full and half bridge sensors Long wire and smaller...

Страница 13: ...ls connected to the sensor and then apply or remove the shunt calibration resistance in software While remote sensing corrects for resistances from the EX terminals on the NI USB 9237 to the sensor sh...

Страница 14: ...ment The 150 mW limit allows you to power full and half bridges as follows Four 350 half bridges at 5 0 V Four 350 full bridges at 3 3 V Four 120 half bridges at 2 5 V If you need an excitation voltag...

Страница 15: ...he NI USB 9237 represents signals within the passband as accurately as possible as quantified primarily by passband flatness and phase nonlinearity The filters reject frequencies within the stopband a...

Страница 16: ...9237 is not an aliased artifact of signals at a higher frequency The alias free bandwidth is defined by the ability of the filter to reject frequencies above the stopband frequency and equals the dat...

Страница 17: ...brated Phase nonlinerarity 0 to 1 kHz 0 001 0 to 20 kHz 0 1 Input delay 4 8 s 38 4 fs Passband Frequency 0 45 fs Flatness 0 1 dB max Error Percent of Reading Gain Error Percent of Range Offset Error C...

Страница 18: ...rth ground2 140 dB 0 to 60 Hz Relative to EX 85 dB 0 to 1 kH Input noise Spurious free dynamic range SFDR 106 dB 1 KHz 60 dBFS Total harmonic distortion fundamental 20 dBFS 1 kHz 100 dB 8 kHz 90 dB Ex...

Страница 19: ...power 150 mW max External voltage 2 V to 10 V Power Requirements Current consumption from USB 500 mA max Suspend mode 2 5 mA max Bus Interface USB specification USB 2 0 Hi Speed Physical Characterist...

Страница 20: ...by regulated low voltage sources and electronics Do not connect the NI USB 9237 to signals or use for measurements within Measurement Categories II III or IV Safety Standards The NI USB 9237 is desig...

Страница 21: ...munity EN 55011 Emissions Group 1 Class A CE C Tick ICES and FCC Part 15 Emissions Class A Note For EMC compliance operate this device with double shielded cables CE Compliance This product meets the...

Страница 22: ...egulations and directives with which NI complies as well as other environmental information not included in this document Waste Electrical and Electronic Equipment WEEE EU Customers At the end of thei...

Страница 23: ...onal Instruments also has offices located around the world to help address your support needs For telephone support in the United States create your service request at ni com support and follow the ca...

Отзывы: