4.
Position the RTI-12306 at the desired slot and insert the securing screws, but do not fully
tighten them.
5.
Insert an SLSC-12251/12252 module into the same slot as its corresponding RTI-12306
while firmly holding the RTI-12306 in place until the RTI-12306 is firmly connected to
the module.
6.
Repeat steps 4 and 5 for all required RTIs.
7.
Fully tighten the screws for all RTIs and the upper rear panel of the chassis.
Note
Waiting until all RTIs and modules are installed to fully tighten the
screws ensures proper alignment for future connections between modules and
RTIs.
8.
Fully tighten the two module mounting screws on each newly installed module.
9.
Power on the SLSC chassis.
Getting Started with Software
Use the following three examples to familiarize yourself with the NI-SLSC API. These
examples can be found at file path
<LabVIEW installation path>\examples\SLSC
\Example Modules\
4
or in
Example Finder: Example Finder>>SLSC>>NI
Module Examples
.
SLSC-12251 & 12252 FIU Module Configuration.vi
This VI demonstrates how to use the NI-SLSC API to configure the switches of the
SLSC-12251 and SLSC-12252 FIU modules.
SLSC-12251 & 12252 FIU Module Fault Monitor.vi
This VI demonstrates how to use the NI-SLSC API to find specific fault locations on the
SLSC-12251 and SLSC-12252 FIU modules when a fault occurs.
SLSC-12251 & 12252 FIU Module Current Sensing.vi
Use this conceptual example to integrate current sensing functionality into your own system.
Note
To use this VI you must connect a voltage measurement device to the RTI
that is attached to the module.
I/O Organization
DUT connector J1 is the input connection to each channel. LOAD connector J2 is the output
connection to each channel. Bus A and Bus B are common connections available to all
channels through the RTI-12306.
4
A common installation path for the 32-bit version of LabVIEW is
C:\Program Files
(x86)\National Instruments\LabVIEW xxxx\examples\SLSC\Example Modules
\.
6
|
ni.com
|
SLSC-12251 and SLSC-12252 User Manual