Chapter 1
Installing and Configuring the SCXI-1581
©
National Instruments Corporation
1-5
SCXI-1581 User Manual
Consult the SCXI chassis documentation, other SCXI module
documentation, and E Series DAQ device documentation for additional
instructions and cautions. You should have already installed the SCXI-1581
module and any other SCXI modules in the chassis according to their
installation instructions.
In the chassis, you must select an analog-input module with simultaneous
sampling capability as the cabled module, to which the SCXI cable
assembly will connect. This includes the SCXI-1520, SCXI-1530/1531,
and SCXI-1140. Refer to the
SCXI Quick Start Guide
for information on
the correct order to install modules. If you cable to a module without
simultaneous sampling capability, you will get an error message each time
you run your application.
Note
The SCXI-1581 is
not
an analog-input module.
To connect the chassis to an E Series DAQ device for multiplexed
operation, complete the following steps while referring to Figure 1-2:
1.
Power off the SCXI chassis.
2.
Power off the computer that contains the E Series DAQ device.
3.
Insert the cable adapter into the back of the SCXI chassis aligned with
the module that you intend to connect to the E Series DAQ device.
Refer to the installation guide for the cable assembly for more
information.
4.
Connect the cable to the back of the cable adapter, ensuring that the
cable fits securely.
5.
Connect the other end of the cable to the E Series DAQ device you are
using to control the SCXI system.
6.
Check the cable installation, making sure the connectors and cable
adapter are securely fastened at both ends.
7.
Power on the SCXI chassis.
8.
Power on the computer.