NI SCC-CTR01 User Guide and Specifications

Electromagnetic Compatibility

This product is designed to meet the requirements of the following 
standards of EMC for electrical equipment for measurement, control, 
and laboratory use:

EN 61326 EMC requirements; Minimum Immunity

EN 55011 Emissions; Group 1, Class A

CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A

Note

For EMC compliance, operate this device according to product documentation.

CE Compliance

This product meets the essential requirements of applicable European 
Directives, as amended for CE marking, as follows:

2006/95/EC; Low-Voltage Directive (safety)

2004/108/EEC; Electromagnetic Compatibility Directive (EMC)

Note

Refer to the Declaration of Conformity (DoC) for this product for any additional 

regulatory compliance information. To obtain the DoC for this product, visit 

ni.com/

certification

, search by model number or product line, and click the appropriate link 

in the Certification column.

Environmental Management

National Instruments is committed to designing and manufacturing 
products in an environmentally responsible manner. NI recognizes that 
eliminating certain hazardous substances from our products is beneficial 
not only to the environment but also to NI customers.

For additional environmental information, refer to the 

NI and the 

Environment

 Web page at 

ni.com/environment

. This page contains the 

environmental regulations and directives with which NI complies, as well 
as other environmental information not included in this document.

Waste Electrical and Electronic Equipment (WEEE)

EU Customers

At the end of their life cycle, all products 

must

 be sent to a WEEE recycling 

center. For more information about WEEE recycling centers and National Instruments 
WEEE initiatives, visit 

ni.com/environment/weee.htm

.

⬉ᄤֵᙃѻક∵ᶧ᥻ࠊㅵ⧚ࡲ⊩ ˄Ё೑

RoHS

˅

Ё೑ᅶ᠋

National Instruments

ヺড়Ё೑⬉ᄤֵᙃѻકЁ䰤ࠊՓ⫼ᶤѯ᳝ᆇ⠽䋼ᣛҸ

 (RoHS)

DŽ

݇Ѣ

National Instruments

Ё೑

RoHS

ড়㾘ᗻֵᙃˈ䇋ⱏᔩ

ni.com/environment/rohs_china

DŽ

(For information about China RoHS compliance, go to 

ni.com/environment/rohs_china

.)

Содержание SCC-CTR01

Страница 1: ...The sequence File Page Setup Options directs you to pull down the File menu select the Page Setup item and select Options from the last dialog box This icon denotes a caution which advises you of prec...

Страница 2: ...C 2345 connector block and the NI SC 2345 with configurable connectors SCC SCC refers to any SCC Series signal conditioning module What You Need to Get Started To set up and use the NI SCC CTR01 you n...

Страница 3: ...All Programs National Instruments NI DAQ DAQ Getting Started Guide The NI DAQ Readme lists which devices are supported by this version of NI DAQ Select Start All Programs National Instruments NI DAQ...

Страница 4: ...s and tools Refer to the following locations on the Contents tab of the LabVIEW Help for information about NI DAQmx Getting Started Getting Started with DAQ Includes overview information and a tutoria...

Страница 5: ...select Measurement Studio NI Measurement Studio Help To create an application in Visual C Visual C or Visual Basic NET follow these general steps 1 In Visual Studio NET select File New Project to laun...

Страница 6: ...he Filtered By drop down list and follow the previous instructions Device Documentation and Specifications NI DAQmx includes the Device Document Browser which contains online documentation for support...

Страница 7: ...re Device Specific Information Note For general SCC module installation and signal connection information and information about the NI SC 2345 carrier refer to the SCC Quick Start Guide available for...

Страница 8: ...gnals Figure 1 illustrates a single isolated input Figure 1 Single Isolated Input Inputs are referenced to either the ground or supply of the external device depending on whether or not the external d...

Страница 9: ...connect the NI SCC CTR01 as referenced to ground and as referenced to the supply Connecting the NI SCC CTR01 as Referenced to Ground Connect the external device to the SRC or GATE pin and connect the...

Страница 10: ...TTL devices reference the NI SCC CTR01 to the supply as shown in Figure 3 Note When placing a relatively slow rise time signal such as a 5 V peak sine or triangle wave on one of the inputs and a fast...

Страница 11: ...in the Specifications section If the amount of current the MOSFET conducts exceeds a certain level 800 mA typical such as when a short occurs in the load the MOSFET turns off for 250 ms to protect it...

Страница 12: ...switch the MOSFET to OFF Driving Inductive Loads Caution When the output of the NI SCC CTR01 is used to drive an inductive load high voltages will appear suddenly because of the current switching thr...

Страница 13: ...the NI SCC CTR01 and other equipment In addition the NI SCC CTR01 is equipped with overvoltage protection and can handle continuous voltages between the and input terminals up to 60 VDC Frequencies o...

Страница 14: ...if the output current exceeds a certain limit 800 mA typical 1 1 A max The NI SCC CTR01 tries to reoperate every 250 ms and automatically recovers after the short is removed Reverse and Overvoltage Pr...

Страница 15: ...by the following equation for a positive pulse in positive logic Example If using typical LOW to HIGH and HIGH to LOW propagation delays relays 180 ns and 150 ns and the actual measured pulse width is...

Страница 16: ...nce to either supply or ground two terminals per input Maximum input frequency 400 kHz Minimum input pulse width 1 s Input to input input to output and input to PC ground isolation 60 VDC continuous v...

Страница 17: ...e switch Output power requirement 5 to 48 VDC 10 mA per channel typical at 400 kHz Load voltage range 5 to 48 VDC Switching current 100 mA max Inrush current 600 mA max Maximum output frequency 400 kH...

Страница 18: ...male connector one 7 pin screw terminal Field wiring diameter 28 to 16 AWG Environmental Operating temperature 0 to 50 C Storage temperature 20 to 70 C Humidity 10 to 90 RH noncondensing Maximum altit...

Страница 19: ...by model number or product line and click the appropriate link in the Certification column Environmental Management National Instruments is committed to designing and manufacturing products in an env...

Страница 20: ...de and Specifications 20 ni com NI SCC SCTRO1 Module Pin Assignments Figure 6 shows the I O connector on the bottom of the NI SCC CTR01 Figure 6 SCC Module Bottom View 1 Pin 1 2 Pin 2 3 PWB Key 4 Pin...

Страница 21: ...s products refer to the appropriate location Help Patents in your software the patents txt file on your CD or ni com patents 2005 2007 National Instruments Corporation All rights reserved 371673B 01 D...