Recoverable POST Error Beep Codes
When a recoverable error occurs during POST, the BIOS displays a POST code that describes
the problem. The BIOS also may issue one of the following beep codes:
•
One long and eight short beeps
: Video configuration error.
•
One repetitive long beep
: No memory detected.
•
One continuous beep with the front panel Overheat LED on
: System overheat.
Rack Mounting
Note
The rack mount kit provided with the NI RMC-8354 is intended to work with
racks that are 26 to 33 in. deep. For information about installing the NI RMC-8354
into a rack that is less than 26 in. deep, refer to KnowledgeBase 4GCEKKMT at
ni.com/support
.
The rack mounting hardware includes:
•
One pair of inner slides to be installed on the chassis.
•
One pair of outer slides to be installed in the rack.
•
Three pairs of short brackets for the outer slides.
•
Bag of assorted fasteners.
•
One pair of long brackets for the rear of the outer slides.
Caution
When mounting the equipment in the rack, do not create a hazardous
condition due to uneven mechanical loading.
Note
One pair of short brackets includes screw threads, and the other two pairs
have slots. If the short brackets are required for your specific rack mounting
configuration, use the pair(s) that fits into your rack best.
Note
Rack mounting hardware provided in the accessory kit, but not specifically
described in the following instructions, is for other possible rack mounting
configurations not mentioned in this manual. Consult any relevant literature provided
with the intended rack for specific mounting information before attempting to install