1.
Touch the antistatic package to a metal part of the chassis before removing the device
from the package.
Caution
Never touch the exposed pins of connectors.
2.
Remove the device from the package and inspect the device for loose components or any
other sign of damage.
3.
Notify National Instruments if the device appears damaged in any way. Do
not
install a
damaged device into your chassis.
Electrical
Power Rail
Typical Value
Max Value
+3.3 VDC
0.62 A
0.93 A
+12 VDC
1.02 A
1.68 A
Total Power
14.28 W
23.23 A
Preparing the Environment
Ensure the environment you are using the PXIe-8238 in meets the following specifications.
Ambient temperature range
0 °C to 55 °C (Tested in accordance with
IEC-60068-2-1 and IEC-60068-2-2.)
Relative humidity range
10% to 90%, noncondensing (Tested in
accordance with IEC-60068-2-56.)
Maximum altitude
2,000 m (800 mbar)
Pollution Degree
2
Indoor use only.
Note
Refer to the
PXIe-8238 User Manual
for full PXIe-8238 specifications.
Hardware Installation
The following are general instructions for installing the PXIe-8238.
Complete the following steps to install the PXIe-8238 in your PXI Express chassis.
1.
Power off your PXI Express chassis, but leave it plugged in while installing the
PXIe-8238. The power cord grounds the chassis and protects it from electrical damage
while you install the module.
Caution
To protect both yourself and the chassis from electrical hazards,
leave the chassis off until you finish installing the PXIe-8238.
2.
Remove or open any doors or covers blocking access to the slot in which you intend to
install the PXIe-8238.
2
|
ni.com
|
PXIe-8238 Getting Started Guide