background image

Verifying Hardware Installation for Remote
Targets

You can verify that the system recognizes the NI PXIe-7822R by using Measurement &
Automation Explorer (MAX).
1.

Launch MAX on the host computer.

2.

Expand 

Remote Targets

 in the configuration tree and locate your system.

3.

Install LabVIEW Real-Time Module 2014 SP1 and NI RIO Device Drivers February
2015 or later on your 

Remote Target

.

a)

Refer to the 

Installing Software on the Host Computer

 section for information about

installing software on the host.

b)

Refer to the 

PXI Express Controllers User Manual

 at 

ni.com/manuals

 for

information on installing software on the target.

4.

Under 

Remote Targets

, find and expand 

Devices and Interfaces

.

If the device does not appear, press <F5> to refresh the view in MAX. If the device does
not appear after refreshing the view, visit 

ni.com/support

 for troubleshooting

information.

Connecting the NI PXIe-7822R

NI recommends using the following cables and accessories with the NI PXIe-7822R:

EMI suppression ferrites (777297-01)

Shielded 68-Pin Connector Block for R Series DIO & HSDIO Products (782914-01)

Shielded R Series High Speed Digital Cable, 1m (156166-01)

Shielded R Series High Speed Digital Cable, 2m (156166-02)

Note

 

NI is not liable for connections that exceed any of the maximum ratings of

input or output signals on the NI PXIe-7822R and on the computer chassis. Refer to
the 

NI PXIe-7822R Specifications

, available at 

ni.com/manuals

 for the maximum

input and output ratings for each signal.

6

  | 

ni.com

  | 

NI PXIe-7822R Getting Started Guide

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание PXIe-7822R

Страница 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Страница 2: ...oduct misuse can result in a hazard You can compromise the safety protection built into the product if the product is damaged in any way If the product is damaged return it to National Instruments for...

Страница 3: ...lded cable If unshielded cables or accessories are not properly installed and shielded the EMC specifications for the product are no longer guaranteed Caution To ensure the specified EMC performance i...

Страница 4: ...ni com manuals for complete specifications Installing Software on the Host Computer Before using the NI PXIe 7822R you must install the following application software and device drivers on the host co...

Страница 5: ...nt panel 5 Identify a supported slot in the chassis The following figure shows the symbols that indicate the slot types Figure 2 Chassis Compatibility Symbols NI PXIe 1062Q 1 2 3 4 5 1 PXI Express Sys...

Страница 6: ...imize cooling air flow 12 Power on the chassis Verifying Hardware Installation for Host Targets You can verify that the system recognizes the NI PXIe 7822R by using Measurement Automation Explorer MAX...

Страница 7: ...t appear press F5 to refresh the view in MAX If the device does not appear after refreshing the view visit ni com support for troubleshooting information Connecting the NI PXIe 7822R NI recommends usi...

Страница 8: ...24 59 25 60 26 61 27 62 28 63 29 64 30 65 31 66 32 67 33 68 34 x is the connector number External Clock x is an input only DIO 0 31 Digital I O data through channels 0 through 31 GND Ground reference...

Страница 9: ...ers on the DIO channels are set as input low with pull down resistors To set another power on state you can configure the NI PXIe 7822R to load a VI when the system powers on The VI can then set the D...

Страница 10: ...ble install two 2 snap on ferrite beads 777297 01 one on each end of the cable as close to the connector as practical Two 2 snap on ferrite beads 777297 01 are included in ach of the following recomme...

Страница 11: ...everything from troubleshooting and application development self help resources to email and phone assistance from NI Application Engineers National Instruments corporate headquarters is located at 1...

Страница 12: ...le for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes ECC...

Страница 13: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Отзывы: