background image

Worldwide Support and Services

The NI website is your complete resource for technical support. At 

ni.com/support

, you have

access to everything from troubleshooting and application development self-help resources to
email and phone assistance from NI Application Engineers.

Visit 

ni.com/services

 for information about the services NI offers.

Visit 

ni.com/register

 to register your NI product. Product registration facilitates technical

support and ensures that you receive important information updates from NI.

NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas,
78759-3504. NI also has offices located around the world. For support in the United States,
create your service request at 

ni.com/support

 or dial 1 866 ASK MYNI (275 6964). For

support outside the United States, visit the 

Worldwide Offices

 section of 

ni.com/niglobal

 to

access the branch office websites, which provide up-to-date contact information.

Information is subject to change without notice. Refer to the NI Trademarks and Logo Guidelines at 

ni.com/trademarks

 for

information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their
respective companies. For patents covering NI products/technology, refer to the appropriate location: 

Help

»

Patents in your

software, the 

patents.txt

 file on your media, or the National Instruments Patent Notice at 

ni.com/patents

. You can find

information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer
to the Export Compliance Information at 

ni.com/legal/export-compliance

 for the NI global trade compliance policy and how

to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS
TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S.
Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable
limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.

© 2013—2019 National Instruments. All rights reserved.

375440B-01

February 14, 2019

Содержание PXIe-5160

Страница 1: ...nstruments folder Contents Verifying the System Requirements 2 Unpacking the Kit 2 Other Equipment 3 Preparing the Environment 4 Installing the Software 4 Installing the PXIe 5160 5162 5 PXIe 5160 5162 Front Panels 7 Configuring the PXIe 5160 5162 in MAX 8 PXIe 5160 5162 Self Calibration 9 Running Self Calibration 9 First Measurements 10 Making a Measurement with InstrumentStudio 10 Making a Measu...

Страница 2: ...ry Information 3 PXIe 5160 5162 Getting Started Guide this document 4 Maintain Forced Air Cooling Note to Users Notice To prevent electrostatic discharge ESD from damaging the module ground yourself using a grounding strap or by holding a grounded object such as your computer chassis 1 Touch the antistatic package to a metal part of the computer chassis 2 Remove the module from the package and ins...

Страница 3: ...er 786983 01 Probes refer to the following table for several options compatible with the PXIe 5160 5162 Table 1 Probe Options for the PXIe 5160 5162 Model NI Part Number Description CP400X 784254 01 400 MHz 2 m 10X cable divider probe CP500X 784253 01 500 MHz 1 2 m 10X cable divider probe NI 5191 781785 01 800 MHz differential active probe SA1000X 784255 01 1 GHz single ended active probe SA1500X ...

Страница 4: ...t 25 C ambient temperature Indoor use only Installing the Software You must be an Administrator to install NI software on your computer 1 Install an ADE such as LabVIEW or LabWindows CVI 2 Visit ni com downloads drivers and search for NI SCOPE 3 Download the latest version of NI SCOPE extract the downloaded files and run the executable exe file Driver support for the PXIe 5160 5162 was first avail...

Страница 5: ...5 Identify a supported slot in the chassis The following figure shows the symbols that indicate the slot types Figure 1 Chassis Compatibility Symbols NI PXIe 1062Q 1 2 3 4 5 1 PXI Express System Controller Slot 2 PXI Peripheral Slot 3 PXI Express Hybrid Peripheral Slot 4 PXI Express System Timing Slot 5 PXI Express Peripheral Slot PXIe 5160 5162 modules can be placed in PXI Express peripheral slot...

Страница 6: ... front panel mounting screws Note Tightening the top and bottom mounting screws increases mechanical stability and also electrically connects the front panel to the chassis which can improve the signal quality and electromagnetic performance 11 Cover all empty slots using EMC filler panels or fill using slot blockers to maximize cooling air flow depending on your application 12 Power on the chassi...

Страница 7: ...3 Note PXIe 5160 shown Table 2 PXIe 5160 5162 Signal Descriptions Signal Connector Type Description CH 0 CH 1 BNC Analog input connection digitizes data and triggers acquisitions CH 2 CH 3 Additional analog input connections on the PXIe 5160 5162 4 CH TRIG External analog trigger connection signals on the TRIG connector cannot be digitized PXIe 5160 5162 2 CH only PXIe 5160 5162 Getting Started Gu...

Страница 8: ...1 Launch MAX 2 In the configuration tree expand Devices and Interfaces to see the list of installed NI hardware Installed modules appear under the name of their associated chassis 3 Expand your Chassis tree item MAX lists all modules installed in the chassis Your default names may vary Note If you do not see your module listed press F5 to refresh the list of installed modules If the module is stil...

Страница 9: ...n cycle Before running self calibration Warm up the PXIe 5160 5162 for at least 15 minutes When possible disconnect the inputs1 PXIe 5160 5162 modules are externally calibrated at the factory but for optimal performance use self calibration in any of the following situations When the module is placed in a new system When the temperature changes more than 3 C from the previous self calibration Once...

Страница 10: ...el is not already running click Run Stop 6 Add oscilloscope measurements to the channel by selecting Add Remove in the measurement table of the oscilloscope For more information on the measurements available for oscilloscopes in InstrumentStudio refer to the InstrumentStudio Manual at ni com manuals Making a Measurement with LabVIEW 1 Launch LabVIEW 2 Select Help Find Examples 3 Open the example V...

Страница 11: ...60 5162 can output a 1 kHz square wave that you can use to compensate passive probes To compensate a passive probe complete the following steps 1 Connect the BNC end of the probe to an input channel of your oscilloscope 2 Depending on your connection method connect the probe tip to the oscilloscope Oscilloscope Probe Compensator 1 Connect the SMB end of the Oscilloscope Probe Compensator to the PF...

Страница 12: ...and adjust the tunable capacitor on the probe The probe is correctly compensated when the waveform appears as square as possible Probe Adjustment Signal Probe Adjustment Signal Probe Adjustment Signal Compensated Correctly Undercompensated Overcompensated Proper Amplitude of a 1 MHz Test Signal Reduced Amplitude of a 1 MHz Test Signal Increased Amplitude of a 1 MHz Test Signal Once compensated the...

Страница 13: ...5162 You can acquire data interactively using InstrumentStudio or you can use the NI SCOPE instrument driver to program your device in the supported ADE of your choice PXIe 5160 5162 Getting Started Guide National Instruments 13 ...

Страница 14: ...populated with NI SCOPE devices From the Windows Start menu select National Instruments InstrumentStudio year This launches InstrumentStudio and runs a soft front panel populated with devices detected on your system From Measurement Automation Explorer MAX select a device and then click Test Panels This launches InstrumentStudio and runs a soft front panel for the device you selected When you inst...

Страница 15: ...a NET example to create an application with Visual Basic NET or Visual C Copy an NI SCOPE example to copy required project settings for include paths and library files Alternatively refer to the Creating an Application section of the NI High Speed Digitizers Help to manually add all required include and library files to your project NI SCOPE Examples Examples demonstrate the functionality of the d...

Страница 16: ...ted power off the system ensure that all hardware is correctly installed and restart the system 4 Navigate to the Device Manager Operating System Description Windows 10 8 1 Right click the Start button and select Device Manager Windows 7 Select Start Control Panel Device Manager 5 Verify the PXIe 5160 5162 appears in the Device Manager a Under an NI entry confirm that a PXIe 5160 5162 entry appear...

Страница 17: ...ere To Go Next Refer to the following figure for information about other product tasks and associated resources for those tasks DISCOVER CREATE LEARN EXPLORE Getting Started with LabWindows CVI Getting Started with LabVIEW Located using the NI Example Finder 500 MHz Oscilloscope NI PXIe 5160 Located online at ni com manuals Services ni com services Support ni com support more about your products t...

Страница 18: ... to the NI Trademarks and Logo Guidelines at ni com trademarks for information on NI trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering NI products technology refer to the appropriate location Help Patents in your software the patents txt file on your media or the National Instruments Patent Notice at ni com ...

Отзывы: