NI PXIe-4353 and TB-4353 Terminal Block Installation Guide
12
ni.com
Figure 8.
Removing the TB-4353 from the NI PXIe-4353 Module (Tilt-Down Method)
3.
Store the terminal block in an antistatic protective bag.
Step 2. Remove the Module
Caution
Do
not
remove a module with the power on. Doing so can damage the module.
1.
Make sure that the chassis is powered off before removing the module.
2.
Loosen the captive screws on the top and bottom of the module.
Caution
Do
not
pull the front panel to remove the module. Doing so may cause module components
to come into contact with adjacent modules, causing damage to the modules.
3.
Pull the captive screws to unseat the module and slowly slide the module along the guides, as shown
in Figure 9.
4.
Replace the filler panel in the empty slot.
5.
Store the module in an antistatic protective bag.