background image

Chapter 2

Installation and Configuration

©

 National Instruments Corporation

2-5

NI PXI-8106 User Manual

BIOS Setup

You can change the NI PXI-8106 configuration settings in the BIOS setup. 
The BIOS is the low-level interface between the hardware and PC software 
that configures and tests your hardware when you boot the system. The 
BIOS setup program includes menus for configuring settings and enabling 
NI PXI-8106 controller features.

Most users do not need to use the BIOS setup program, as the NI PXI-8106 
controller ships with default settings that work well for most 
configurations.

Caution

Changing BIOS settings may lead to incorrect controller behavior and possibly 

an unbootable controller. If this happens, follow the instructions for restoring default 
settings in the 

System CMOS

 section. In general, do 

not

 change a setting unless you are 

absolutely certain what it does.

Entering BIOS Setup

To start the BIOS setup utility, complete the following steps:

1.

Power on or reboot your NI PXI-8106 controller.

2.

When the message 

Press <DEL> to enter SETUP

 appears, press 

the Delete key on the keyboard. The message 

Entering Setup

 

appears, and the setup program is loaded after a short delay.

3.

When you first enter the BIOS setup program, it displays the 

Main

 

menu.

Use the following keys to navigate through the BIOS setup:

Left Arrow, Right Arrow

—Use these keys to move between the 

different setup menus. If you are in a submenu, these keys have no 
effect, and you need to press <Esc> to leave the submenu first. (To use 
the arrows on the numeric keypad, you must turn off Num Lock.)

Up Arrow, Down Arrow

—Use these keys to move between the 

options within a setup menu. (To use the arrows on the numeric 
keypad, you must turn off Num Lock.)

<Enter>

—Use this key either to enter a submenu or display all 

available settings for a highlighted configuration option.

<Esc>

—Use this key to return the parent menu of a submenu. 

At the top-level menus, this key serves as a shortcut to the 

Exit

 menu.

Содержание PXI-8106

Страница 1: ...PXI NI PXI 8106 User Manual NI PXI 8106 User Manual January 2007 372096A 01...

Страница 2: ...rea 82 02 3451 3400 Lebanon 961 0 1 33 28 28 Malaysia 1800 887710 Mexico 01 800 010 0793 Netherlands 31 0 348 433 466 New Zealand 0800 553 322 Norway 47 0 66 90 76 60 Poland 48 22 3390150 Portugal 351...

Страница 3: ...ing photocopying recording storing in an information retrieval system or translating in whole or in part without the prior written consent of National Instruments Corporation National Instruments resp...

Страница 4: ...t of Communications DOC Changes or modifications not expressly approved by NI could void the user s authority to operate the equipment under the FCC Rules Class A Federal Communications Commission Thi...

Страница 5: ...the Controller from the PXI Chassis 2 4 BIOS Setup 2 5 Entering BIOS Setup 2 5 Main Setup Menu 2 6 Advanced Setup Menu 2 6 PXI Setup Menu 2 10 LabVIEW RT Options Setup Menu 2 10 Security Menu 2 11 Boo...

Страница 6: ...7 Universal Serial Bus 3 9 Trigger 3 10 GPIB IEEE 488 2 3 11 ExpressCard 34 Slot 3 12 Front Panel Features 3 14 Data Storage 3 14 Chapter 4 Common Configuration Questions General Questions 4 1 Boot Op...

Страница 7: ...down the File menu select the Page Setup item and select Options from the last dialog box This icon denotes a note which alerts you to important information This icon denotes a caution which advises y...

Страница 8: ...ard P1284 1 1997 C MM Standard for Information Technology for Transport Independent Printer System Interface PCI Local Bus Specification Revision 2 3 PCI Special Interest Group PXI Hardware Specificat...

Страница 9: ...suited for industrial applications PXI leverages from the CompactPCI specification which defines a rugged form factor for PCI that offers superior mechanical integrity and easy installation and remov...

Страница 10: ...aution ESD An electrostatic discharge event to the ExpressCard port may cause the controller to restart This is an Electromagnetic Compatibility Performance Criteria C non continuous operation for ESD...

Страница 11: ...lowing the diagram is a description of each logic block shown Figure 1 1 NI PXI 8106 Block Diagram DUAL CH Chipset Graphics Memory Controller Hub Socket 479 CPU Super I O COM 1 LPT 1 Chipset I O Contr...

Страница 12: ...e NI PXI 8106 to the PXI CompactPCI backplane The Super I O block represents the other peripherals supplied by the NI PXI 8106 The NI PXI 8106 has one serial port and an ECP EPP parallel port The Giga...

Страница 13: ...as well as utilities for building automated test systems monitoring applications or laboratory experiments For more information visit ni com lwcvi NI DAQmx provides an extensive library of functions...

Страница 14: ...ing and controlling USB Serial GPIB PXI VXI and various other types of instruments This API aids in the creation of portable applications and instrument drivers For information on writing your own PXI...

Страница 15: ...ings 1 Plug in your chassis before installing the NI PXI 8106 The power cord grounds the chassis and protects it from electrical damage while you install the module Make sure the power switch is turne...

Страница 16: ...osition Align the NI PXI 8106 with the card guides on the top and bottom of the system controller slot Caution Do not raise the injector ejector handle as you insert the NI PXI 8106 The module will no...

Страница 17: ...0 Connect the keyboard and mouse to the appropriate connectors If you are using a PS 2 keyboard and a PS 2 mouse a Y splitter adapter is available to connect both to a single USB connector Refer to Fi...

Страница 18: ...Controller from the PXI Chassis The NI PXI 8106 controller is designed for easy handling To remove the unit from the PXI chassis complete the following steps 1 Power off the chassis 2 Remove any cable...

Страница 19: ...ring BIOS Setup To start the BIOS setup utility complete the following steps 1 Power on or reboot your NI PXI 8106 controller 2 When the message Press DEL to enter SETUP appears press the Delete key o...

Страница 20: ...eadless mode you must set this option to Disabled The default value is Enabled Note Attaching a USB to PS 2 keyboard adapter may allow the system to boot even if no PS 2 keyboard is attached Num Lock...

Страница 21: ...re skipped to shorten controller boot time The default is Enabled Summary Screen This setting controls the display of the summary screen shown after BIOS completes its initialization but before bootin...

Страница 22: ...advanced features of a SATA controller while Compatible mode provides legacy backwards compatibility with standard ATA for operating systems that do not natively support SATA The default setting is En...

Страница 23: ...when hot plugging an ExpressCard device The default setting is Enabled Hot Plug Bus Gap This setting determines the number of PCI buses that will be reserved by the BIOS for ExpressCard PCI PCI bridg...

Страница 24: ...fer to the Per Slot Device Settings Submenu section Per Slot Device Settings Submenu Use this menu to configure options that can be modified for individual PCI devices in a PXI chassis Note Scanning f...

Страница 25: ...bled only when the boot switch is also set to On to boot LabVIEW RT The default setting is Auto Security Menu Use this menu to enable BIOS security options Set User Password This setting allows you to...

Страница 26: ...vailable options for exiting saving and loading the BIOS default configuration As an alternative to this screen press F9 to load BIOS default settings and F10 to save changes and exit setup The Exit s...

Страница 27: ...e setup program remains active allowing further changes System CMOS The NI PXI 8106 contains a backed up memory used to store BIOS configuration information Complete the following steps to clear the C...

Страница 28: ...on the controller If you are not using LabVIEW RT these switches should remain in the OFF position The controller reads these switches only after a system reset You must reboot the controller for any...

Страница 29: ...ormal operation Switch 3 Disable Startup VI Set this switch to ON to prevent VIs from automatically running at startup if the controller becomes inaccessible because of a startup VI Switch 4 Reset IP...

Страница 30: ...t directory You will see several files one corresponding to each device The os directory contains a subdirectory corresponding to the operating system installed on your controller The rest of the dire...

Страница 31: ...Measurement Automation Explorer MAX included with the software pre installed on your controller MAX creates the pxisys ini file which defines the layout and parameters of your PXI system The configur...

Страница 32: ...odules To assist system integrators the manufacturers of PXI chassis and system modules must document the capabilities of their products The minimum documentation requirements are contained in ini fil...

Страница 33: ...nce will be slower than using two matched modules However two mismatched modules will result in better performance than using a single module National Instruments offers the following types of SO DIMM...

Страница 34: ...m onto your hard drive through an external CD ROM For more information on these tools refer to the documentation on your hard drive in the c Images Recovery directory or KnowledgeBase 2ZKC02OK at ni c...

Страница 35: ...rives have DOS drivers As an alternative to a USB CD ROM drive you can use an external SCSI CD ROM with a PXI SCSI adapter Note For additional assistance with installing or changing an operating syste...

Страница 36: ...rd vendor for more information Caution The ExpressCard interface is ESD sensitive An electrostatic shock on the ExpressCard module while it is inserted may cause the controller to lock up or reboot Re...

Страница 37: ...iption Video DVI I 24 pin DSUB Intel Extreme Graphics controller Serial COM1 9 pin DSUB 16550 RS 232 serial port Ethernet LAN RJ45 10 100 1000 Ethernet connection Parallel Parallel Port 36 pin champ I...

Страница 38: ...he NI PXI 8106 Dimensions are in inches millimeters Figure 3 1 NI PXI 8106 Front Panel Layout and Dimensions 4 393 111 58 3 840 97 53 3 551 90 19 3 165 80 38 2 490 63 24 2 063 52 4 1 550 39 37 1 069 2...

Страница 39: ...connector on the NI PXI 8106 Table 3 2 lists and describes the DVI I connector signals Figure 3 2 DVI I Connector Location and Pinout Table 3 2 DVI I Connector Signals Pin Signal Name 1 TMDS Data2 2...

Страница 40: ...ower 15 Ground for 5 V 16 Hot Plug Detect 17 TMDS Data0 18 TMDSData0 19 TMDS Data0 5 Shield 20 Reserved 21 Reserved 22 TMDS Clock Shield 23 TMDS Clock 24 TMDS Clock C1 Analog Red C2 Analog Green C3 An...

Страница 41: ...106 Table 3 3 lists and describes the COM1 connector signal Figure 3 3 COM1 Connector Location and Pinout Table 3 3 COM1 Connector Signals Pin Signal Name Signal Description 1 DCD Data Carrier Detect...

Страница 42: ...ts and describes the Ethernet connector signals Figure 3 4 Ethernet Connector Location and Pinout Note The Ethernet controller can perform automatic crossover thus eliminating the need for crossover c...

Страница 43: ...ational Instruments part number 777169 01 Figure 3 5 Parallel Port Connector Location and Pinout Table 3 5 10 100 1000 LAN Connector LED States LED Color LED State Condition Top Green Off LAN link is...

Страница 44: ...SY Device Busy 2 SLCT Select 3 ACK Acknowledge 4 FAULT ERROR Fault 5 PAPEREND Paper End 6 PD0 Data Bit 0 7 PD1 Data Bit 1 8 PD 2 Data Bit 2 9 PD3 Data Bit 3 10 PD4 Data Bit 4 11 PD5 Data Bit 5 12 PD6...

Страница 45: ...the location and pinouts for the Universal Serial Bus USB connectors on the NI PXI 8106 Table 3 7 lists and describes the USB connector signals Figure 3 6 USB Connector Location and Pinout Table 3 7 U...

Страница 46: ...r routing PXI triggers to or from the backplane trigger bus Figure 3 7 shows the TRIG connector location on the NI PXI 8106 Table 3 8 lists and describes the trigger connector signals Figure 3 7 TRIG...

Страница 47: ...nnector signals National Instruments provides a GPIB mating connector part number 183285 0R2 Figure 3 8 GPIB Connector Location and Pinout Table 3 9 GPIB Connector Signals Pin Signal Name Signal Descr...

Страница 48: ...igure 3 9 shows the location and pinouts for the ExpressCard 34 slot on the NI PXI 8106 Table 3 10 lists and describes the ExpressCard connector signals Figure 3 9 ExpressCard 34 Slot Location and Pin...

Страница 49: ...by spec for future use 6 RESERVED Reserved by spec for future use 7 SMBCLK SMBus Clock 8 SMBDATA SMBus Data 9 1 5V Power 10 1 5V Power 11 WAKE PE Wake 12 3 3VAUX Power 13 PERST PE Reset 14 3 3V Power...

Страница 50: ...ing states ON steady PXI and onboard power is on and within regulation limits Blinking One of the PXI or onboard supplies is operating outside of the normal limits or is not functioning OFF The power...

Страница 51: ...on You can view these parameters in the BIOS setup To enter the BIOS setup reboot the NI PXI 8106 and press Delete during the memory tests Refer to the Entering BIOS Setup section of Chapter 2 Instal...

Страница 52: ...vices ordered by device type You can set the boot order using and Set the order by device type and set the order for the devices listed within the device type To boot from a different device without p...

Страница 53: ...ducts How do I connect a VGA monitor to the NI PXI 8106 A VGA to DVI I adapter part number 762559 01 is included with your kit You can use this adapter to connect a VGA monitor to the DVI I port Softw...

Страница 54: ...the NI PXI 8106 from the PXI chassis To optimize both memory capacity and system performance use the same size and speed memory module in each of the two module slots The use of different size modules...

Страница 55: ...nstruments software is available from ni com downloads For peripheral drivers refer to KnowledgeBase 3H3COSD8 at ni com My NI PXI 8106 does not have an internal floppy drive Is there a way to use an e...

Страница 56: ...to the PXI Features section of Chapter 2 Installation and Configuration Why doesn t the NI PXI 8106 work with the PXI 8220 or PXI 8221 A serialized IRQ conflict with the PXI 8220 8221 and the NI PXI...

Страница 57: ...monitor Does your monitor work with a different PC If it hangs note the last screen output that you saw for reference when consulting National Instruments technical support What has changed about the...

Страница 58: ...wer and larger one If the system has been booted to Windows without a monitor attached the driver may have defaulted to the video output connector being disabled Press Ctrl Alt F1 to re enable the vid...

Страница 59: ...om the chassis 3 Move the jumper on W7 from pins 1 2 to pins 2 3 as shown in Figure 5 1 4 Wait one second Move the jumper back to pins 1 2 5 Reinstall the controller in the chassis Caution Do not leav...

Страница 60: ...ensions PXI 3U size module 8 1 cm 13 cm 21 6 cm 3 2 in 5 1 in 8 5 in Slot requirements One system slot plus three controller expansion slots Compatibility Fully compatible with PXI specification Weigh...

Страница 61: ...e with IEC 60068 2 1 and IEC 60068 2 2 Relative humidity range 10 to 90 noncondensing Tested in accordance with IEC 60068 2 56 Caution Clean the NI PXI 8106 with a soft nonmetallic brush Make sure tha...

Страница 62: ...of the following standards of safety for electrical equipment for measurement control and laboratory use EN 61010 1 IEC 61010 1 UL 61010 1 CSA 61010 1 Note For UL and other safety certifications refe...

Страница 63: ...f Conformity DoC for this product for any additional regulatory compliance information To obtain the DoC for this product visit ni com certification search by model number or product line and click th...

Страница 64: ...truments Application Engineers make sure every question receives an answer For information about other technical support options in your area visit ni com services or contact your local office at ni c...

Страница 65: ...m calibration If you searched ni com and could not find the answers you need contact your local office or NI corporate headquarters Phone numbers for our worldwide offices are listed at the front of t...

Страница 66: ...PXI 8106 User Manual Glossary Symbol Prefix Value n nano 10 9 micro 10 6 m milli 10 3 k kilo 103 M mega 106 G giga 109 T tera 1012 Symbols Degrees Ohms Percent A A Amperes AC Alternating Current ASIC...

Страница 67: ...uctor A type of integrated circuit CompactPCI An adaptation of the PCI specification for industrial and or embedded applications that require a more robust mechanical form factor than desktop PCI Comp...

Страница 68: ...onically Erasable Programmable Read Only Memory EMC Electromagnetic Compatibility EMI Electromagnetic interference EPP Enhanced Parallel Port expansion ROM An onboard EEPROM that may contain device sp...

Страница 69: ...errupt A means for a device to request service from another device interrupt level The relative priority at which a device can interrupt IRQ Interrupt request signal ISA Industry Standard Architecture...

Страница 70: ...coprocessor errors P PCI Peripheral Component Interconnect The PCI bus is a high performance 32 bit or 64 bit bus with multiplexed address and data lines PCI Express Peripheral Component Interconnect...

Страница 71: ...squared See also grms RTC Real Time Clock An electronic circuit that maintains the time of day and also can provide timing signals for timesharing operations S s Seconds slave A functional part of a...

Страница 72: ...Glossary National Instruments Corporation G 7 NI PXI 8106 User Manual V V Volts VGA Video Graphics Array The minimum video display standard for all PCs W W Watts...

Страница 73: ...ctor signals table 3 5 common configuration questions boot options 4 1 cables and connections 4 2 chassis configuration 2 17 figure 2 17 driver installation 4 3 general questions 4 1 PXI configuration...

Страница 74: ...s table 3 6 examples NI resources B 1 Exiting BIOS Setup menu 2 12 ExpressCard 2 21 3 12 connector location and pinout figure 3 12 installing a module 2 21 removing a module 2 22 F files and directori...

Страница 75: ...truments software 1 4 support and services B 1 NI PXI 8106 benefits of PXI 1 1 BIOS setup 2 5 block diagram 1 3 connectors 3 1 COM1 connector and signals 3 5 DVI I connector and signals table 3 3 Expr...

Страница 76: ...th 4 6 pxisys ini file 2 17 R RAM DDR2 SO DIMMs from National Instruments note 2 19 4 4 upgrading 2 19 4 4 related documentation viii S safety specifications table A 3 serial port 3 1 See also COM1 co...

Страница 77: ...ontroller does not boot 5 1 damaged module 5 2 NI resources B 1 video display 5 2 U Universal Serial Bus USB 3 1 3 9 connector function 1 4 connector location and pinout figure 3 9 connector signals t...

Отзывы: