background image

 

Important Information

Warranty

The NI PXI-8101 and NI PXI-8102 are warranted against defects in materials and workmanship for a period of one year from the date of 
shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to 
be defective during the warranty period. This warranty includes parts and labor. 
The media on which you receive National Instruments software are warranted not to fail to execute programming instructions, due to defects in 
materials and workmanship, for a period of 90 days from date of shipment, as evidenced by receipts or other documentation. National Instruments 
will, at its option, repair or replace software media that do not execute programming instructions if National Instruments receives notice of such defects 
during the warranty period. National Instruments does not warrant that the operation of the software shall be uninterrupted or error free.
A Return Material Authorization (RMA) number must be obtained from the factory and clearly marked on the outside of the package before any 
equipment will be accepted for warranty work. National Instruments will pay the shipping costs of returning to the owner parts which are covered by 
warranty.
National Instruments believes that the information in this document is accurate. The document has been carefully reviewed for technical accuracy. In 
the event that technical or typographical errors exist, National Instruments reserves the right to make changes to subsequent editions of this document 
without prior notice to holders of this edition. The reader should consult National Instruments if errors are suspected. In no event shall National 
Instruments be liable for any damages arising out of or related to this document or the information contained in it.
E

XCEPT

 

AS

 

SPECIFIED

 

HEREIN

, N

ATIONAL

 I

NSTRUMENTS

 

MAKES

 

NO

 

WARRANTIES

EXPRESS

 

OR

 

IMPLIED

AND

 

SPECIFICALLY

 

DISCLAIMS

 

ANY

 

WARRANTY

 

OF

 

MERCHANTABILITY

 

OR

 

FITNESS

 

FOR

 

A

 

PARTICULAR

 

PURPOSE

. C

USTOMER

S

 

RIGHT

 

TO

 

RECOVER

 

DAMAGES

 

CAUSED

 

BY

 

FAULT

 

OR

 

NEGLIGENCE

 

ON

 

THE

 

PART

 

OF

 N

ATIONAL

 

I

NSTRUMENTS

 

SHALL

 

BE

 

LIMITED

 

TO

 

THE

 

AMOUNT

 

THERETOFORE

 

PAID

 

BY

 

THE

 

CUSTOMER

. N

ATIONAL

 I

NSTRUMENTS

 

WILL

 

NOT

 

BE

 

LIABLE

 

FOR

 

DAMAGES

 

RESULTING

 

FROM

 

LOSS

 

OF

 

DATA

PROFITS

USE

 

OF

 

PRODUCTS

OR

 

INCIDENTAL

 

OR

 

CONSEQUENTIAL

 

DAMAGES

EVEN

 

IF

 

ADVISED

 

OF

 

THE

 

POSSIBILITY

 

THEREOF

. This limitation of 

the liability of National Instruments will apply regardless of the form of action, whether in contract or tort, including negligence. Any action against 
National Instruments must be brought within one year after the cause of action accrues. National Instruments shall not be liable for any delay in 
performance due to causes beyond its reasonable control. The warranty provided herein does not cover damages, defects, malfunctions, or service 
failures caused by owner’s failure to follow the National Instruments installation, operation, or maintenance instructions; owner’s modification of the 
product; owner’s abuse, misuse, or negligent acts; and power failure or surges, fire, flood, accident, actions of third parties, or other events outside 
reasonable control.

Copyright

Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying, 
recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National 
Instruments Corporation.
National Instruments respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other 
intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only 
to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.

Trademarks

CVI, LabVIEW, National Instruments, NI, ni.com, the National Instruments corporate logo, and the Eagle logo are trademarks of National 
Instruments Corporation. Refer to the 

Trademark Information

 at 

ni.com/trademarks

 for other National Instruments trademarks.

The mark LabWindows is used under a license from Microsoft Corporation. Windows is a registered trademark of Microsoft Corporation in the United 
States and other countries. Other product and company names mentioned herein are trademarks or trade names of their respective companies. 
Members of the National Instruments Alliance Partner Program are business entities independent from National Instruments and have no agency, 
partnership, or joint-venture relationship with National Instruments.

Patents

For patents covering National Instruments products/technology, refer to the appropriate location: 

Help»Patents

 in your software, 

the

patents.txt

 file on your media, or the 

National Instruments Patent Notice

 at 

ni.com/patents

.

WARNING REGARDING USE OF NATIONAL INSTRUMENTS PRODUCTS

(1) NATIONAL INSTRUMENTS PRODUCTS ARE NOT DESIGNED WITH COMPONENTS AND TESTING FOR A LEVEL OF 
RELIABILITY SUITABLE FOR USE IN OR IN CONNECTION WITH SURGICAL IMPLANTS OR AS CRITICAL COMPONENTS IN 
ANY LIFE SUPPORT SYSTEMS WHOSE FAILURE TO PERFORM CAN REASONABLY BE EXPECTED TO CAUSE SIGNIFICANT 
INJURY TO A HUMAN.

(2) IN ANY APPLICATION, INCLUDING THE ABOVE, RELIABILITY OF OPERATION OF THE SOFTWARE PRODUCTS CAN BE 
IMPAIRED BY ADVERSE FACTORS, INCLUDING BUT NOT LIMITED TO FLUCTUATIONS IN ELECTRICAL POWER SUPPLY, 
COMPUTER HARDWARE MALFUNCTIONS, COMPUTER OPERATING SYSTEM SOFTWARE FITNESS, FITNESS OF COMPILERS 
AND DEVELOPMENT SOFTWARE USED TO DEVELOP AN APPLICATION, INSTALLATION ERRORS, SOFTWARE AND HARDWARE 
COMPATIBILITY PROBLEMS, MALFUNCTIONS OR FAILURES OF ELECTRONIC MONITORING OR CONTROL DEVICES, 
TRANSIENT FAILURES OF ELECTRONIC SYSTEMS (HARDWARE AND/OR SOFTWARE), UNANTICIPATED USES OR MISUSES, OR 
ERRORS ON THE PART OF THE USER OR APPLICATIONS DESIGNER (ADVERSE FACTORS SUCH AS THESE ARE HEREAFTER 
COLLECTIVELY TERMED “SYSTEM FAILURES”). ANY APPLICATION WHERE A SYSTEM FAILURE WOULD CREATE A RISK OF 
HARM TO PROPERTY OR PERSONS (INCLUDING THE RISK OF BODILY INJURY AND DEATH) SHOULD NOT BE RELIANT SOLELY 
UPON ONE FORM OF ELECTRONIC SYSTEM DUE TO THE RISK OF SYSTEM FAILURE. TO AVOID DAMAGE, INJURY, OR DEATH, 
THE USER OR APPLICATION DESIGNER MUST TAKE REASONABLY PRUDENT STEPS TO PROTECT AGAINST SYSTEM FAILURES, 
INCLUDING BUT NOT LIMITED TO BACK-UP OR SHUT DOWN MECHANISMS. BECAUSE EACH END-USER SYSTEM IS 
CUSTOMIZED AND DIFFERS FROM NATIONAL INSTRUMENTS' TESTING PLATFORMS AND BECAUSE A USER OR APPLICATION 
DESIGNER MAY USE NATIONAL INSTRUMENTS PRODUCTS IN COMBINATION WITH OTHER PRODUCTS IN A MANNER NOT 
EVALUATED OR CONTEMPLATED BY NATIONAL INSTRUMENTS, THE USER OR APPLICATION DESIGNER IS ULTIMATELY 
RESPONSIBLE FOR VERIFYING AND VALIDATING THE SUITABILITY OF NATIONAL INSTRUMENTS PRODUCTS WHENEVER 
NATIONAL INSTRUMENTS PRODUCTS ARE INCORPORATED IN A SYSTEM OR APPLICATION, INCLUDING, WITHOUT 
LIMITATION, THE APPROPRIATE DESIGN, PROCESS AND SAFETY LEVEL OF SUCH SYSTEM OR APPLICATION.

Содержание PXI-8101

Страница 1: ...PXI NI PXI 8101 8102 User Manual NI PXI 8101 8102 User Manual June 2010 372800C 01...

Страница 2: ...banon 961 0 1 33 28 28 Malaysia 1800 887710 Mexico 01 800 010 0793 Netherlands 31 0 348 433 466 New Zealand 0800 553 322 Norway 47 0 66 90 76 60 Poland 48 22 328 90 10 Portugal 351 210 311 210 Russia...

Страница 3: ...en consent of National Instruments Corporation National Instruments respects the intellectual property of others and we ask our users to do the same NI software is protected by copyright and other int...

Страница 4: ...e encouraged to try to correct the interference by one or more of the following measures Reorient the antenna of the receiver the device suffering interference Relocate the transmitter the device gene...

Страница 5: ...is 2 4 BIOS Setup 2 5 Accessing BIOS Setup Utility 2 5 Main Setup Menu 2 6 Advanced Setup Menu 2 6 SATA Configuration Submenu 2 7 CPU Configuration Submenu NI PXI 8102 Only 2 7 Video Configuration Sub...

Страница 6: ...Configuration 2 21 Basic PXI System Configuration 2 22 Upgrading RAM 2 23 Hard Drive Recovery 2 24 Installing an OS 2 24 Installing from a USB CD DVD ROM 2 24 Chapter 3 I O Information Front Panel Co...

Страница 7: ...Contents National Instruments Corporation vii NI PXI 8101 8102 User Manual Chapter 5 Troubleshooting Appendix A Specifications Appendix B Technical Support and Professional Services Glossary Index...

Страница 8: ...symbol leads you through nested menu items and dialog box options to a final action The sequence File Page Setup Options directs you to pull down the File menu select the Page Setup item and select O...

Страница 9: ...n this font denotes a specific platform and indicates that the text following it applies only to that platform Related Documentation The following documents contain information you may find helpful as...

Страница 10: ...ges from the CompactPCI specification which defines a rugged form factor for PCI that offers superior mechanical integrity and easy installation and removal of hardware components PXI products offer h...

Страница 11: ...r hard drive The NI PXI 8101 RT Flash HD version of the NI PXI 8101 has a 4 GB or larger Flash hard drive The NI PXI 8102 has an Intel Celeron Dual Core T3100 processor 1 9 GHz with all the standard I...

Страница 12: ...479 CPU is the socket definition for the Intel Celeron 575 and Intel Dual Core T3100 processors The SO DIMM block consists of one 64 bit DDR2 SDRAM socket that can hold up to 4 GB PCI Bus Super I O C...

Страница 13: ...Mbit Ethernet interfaces The SATA block connects a Serial ATA hard drive to the ICH9M National Instruments Software National Instruments has developed several software tools you can use with the NI P...

Страница 14: ...nalog input A D conversion buffered data acquisition high speed A D conversion analog output D A conversion waveform generation digital I O counter timer operations SCXI signal conditioning RTSI or PX...

Страница 15: ...For information on writing your own PXI instrument driver with NI VISA refer to the NI VISA Getting Started Manual and the readme txt file in the NI VISA directory For more information visit ni com v...

Страница 16: ...warnings 1 Plug in your chassis before installing the NI PXI 8101 8102 The power cord grounds the chassis and protects it from electrical damage while you install the module Make sure the power switc...

Страница 17: ...ake sure the injector ejector handle is in its downward position Align the NI PXI 8101 8102 with the card guides on the top and bottom of the system controller slot Caution Do not raise the injector e...

Страница 18: ...re the NI PXI 8101 8102 to the chassis 9 Check the installation 10 Connect the keyboard and mouse to the appropriate connectors If you are using a PS 2 keyboard and a PS 2 mouse a Y splitter adapter i...

Страница 19: ...assis How to Remove the Controller from the PXI Chassis The NI PXI 8101 8102 controller is designed for easy handling To remove the unit from the PXI chassis complete the following steps 1 Power off t...

Страница 20: ...mplete the following steps to start the BIOS setup program 1 Power on or reboot your NI PXI 8101 8102 controller 2 When the message DEL BIOS Setup Menu appears press the Del key The setup program load...

Страница 21: ...This setting controls the time of day which is stored in a battery backed real time clock Most operating systems also include a way to change this setting Use and in conjunction with Enter and Tab to...

Страница 22: ...figuration Submenu Use this submenu to apply alternate settings to the hard disk drive HDD interfaces Normally you do not need to modify these settings as the factory default settings provide the most...

Страница 23: ...ether or not the DDC is routed for an analog monitor or a DVI monitor In order to use a DVI monitor this setting must be set to DVI An analog monitor however will function with this option set to eith...

Страница 24: ...factory default settings provide the most compatible and optimal configuration possible Serial Port 0 Configuration Use this setting to access the Serial Port 0 Configuration submenu Refer to the Ser...

Страница 25: ...m The default value is Disabled LabVIEW RT Options Setup Menu Use this menu to configure boot options for LabVIEW RT if it is installed on the controller If you are not using LabVIEW RT you should lea...

Страница 26: ...e displayed in the Boot Option Priorities menu allowing you to boot from a PXE server on the local subnet Note that the Intel Boot Agent device is named IBA GE Slot 00c9 v1310 in the Boot Option Prior...

Страница 27: ...access the Network Device BBS Priorities submenu to re order or disable bootable network devices Refer to the Network Device BBS Priorities Submenu section for more information Boot Settings Configur...

Страница 28: ...Option 1 Boot Option 2 Boot Option 3 These settings specify the boot priority of network devices The highest priority device is displayed on the main Boot Option Priorities list Optionally each device...

Страница 29: ...ion of the BIOS setup program are discarded The BIOS setup continues to be active Restore Factory Defaults This option restores all BIOS settings to the factory default This option is useful if the co...

Страница 30: ...to store BIOS configuration information Complete the following steps to clear the CMOS contents 1 Power off the chassis 2 Remove the controller from the chassis 3 Press and hold down push button switc...

Страница 31: ...into LabVIEW RT Safe Mode when no software is installed LabVIEW RT Safe Mode loads with the basic real time operating system and will automatically attempt to connect to the network using DHCP If DHCP...

Страница 32: ...work Settings book accessible by browsing to MAX Remote Systems Help LabVIEW Real Time Target Configuration Configuring Network Settings from the Contents tab of MAX Help Note When any IP or identific...

Страница 33: ...ch and select Software 7 Click the Add Remove Software button in the toolbar to launch the LabVIEW Real Time Software Wizard 8 Install the LabVIEW Real Time software and device drivers that you requir...

Страница 34: ...and to download or update software from a host computer This switch overrides the behavior of Switch 1 Booting the controller into safe mode does not start the embedded LabVIEW RT engine After changi...

Страница 35: ...es Installed on Your Hard Drive Your hard drive includes a directory called images in its root that contains software and soft copies of manuals for the installed devices The directory structure under...

Страница 36: ...These files and directories are copied exactly from the manufacturer distribution disks so the naming conventions vary from device to device PXI Features PXI Trigger Connectivity The SMB connector on...

Страница 37: ...as not yet been configured it is labeled PXI System Unidentified Right click this entry to display the pop up menu then select the appropriate controller model from the Identify As submenu 4 Click the...

Страница 38: ...DIMM National Instruments offers the following types of SO DIMMs for use with the NI PXI 8101 8102 controller PC2 6400 1 GB 128 MB 64 1 18 in max PC2 6400 2 GB 256 MB 64 1 18 in max PC2 6400 4 GB 512...

Страница 39: ...cess If you need to recover your factory installed operating system from a DVD you can use the included OS re installation DVD with an external USB DVD ROM drive Boot the PXI controller using the OS r...

Страница 40: ...s Table 3 1 NI PXI 8101 8102 I O Overview I O Interface External Connector Description Video DVI I 24 pin DSUB Intel Extreme Graphics controller Serial COM1 9 pin DSUB 16550 RS 232 serial port Etherne...

Страница 41: ...layout and dimensions Dimensions are in inches millimeters Figure 3 1 NI PXI 8101 Front Panel Layout and Dimensions 4 393 in 111 58 mm 3 551 in 90 2 mm 3 022 in 76 76 mm 2 063 in 52 4 mm 1 069 in 27 1...

Страница 42: ...I 8101 8102 Table 3 2 lists and describes the DVI I connector signals Figure 3 2 DVI I Connector Location and Pinout Table 3 2 DVI I Connector Signals Pin Signal Name 1 TMDS Data2 2 TMDS Data2 3 TMDS...

Страница 43: ...15 Ground for 5 V 16 Hot Plug Detect 17 TMDS Data0 18 TMDSData0 19 TMDS Data0 5 Shield 20 Reserved 21 Reserved 22 TMDS Clock Shield 23 TMDS Clock 24 TMDS Clock C1 Analog Red C2 Analog Green C3 Analog...

Страница 44: ...3 lists and describes the COM1 connector signal Figure 3 3 COM1 Connector Location and Pinout Table 3 3 COM1 Connector Signals Pin Signal Name Signal Description 1 DCD Data Carrier Detect 2 RXD Recei...

Страница 45: ...ribes the Ethernet connector signals Figure 3 4 Ethernet Connector Location and Pinout Note The Ethernet controller can perform automatic crossover thus eliminating the need for crossover cables Table...

Страница 46: ...truments part number 777169 01 Figure 3 5 Parallel Port Connector Location and Pinout Table 3 5 10 100 1000 LAN Connector LED States LED Color LED State Condition Top Green Off LAN link is not establi...

Страница 47: ...BUSY Device Busy 2 SLCT Select 3 ACK Acknowledge 4 FAULT ERROR Fault 5 PAPEREND Paper End 6 PD0 Data Bit 0 7 PD1 Data Bit 1 8 PD 2 Data Bit 2 9 PD3 Data Bit 3 10 PD4 Data Bit 4 11 PD5 Data Bit 5 12 P...

Страница 48: ...it around all attached external USB cables to ensure that your device meets all EMC standards applicable to your country Install the ferrite so that each USB cable loops through the ferrite as shown i...

Страница 49: ...TRIG connector is the software controlled trigger connection for routing PXI triggers to or from the backplane trigger bus Figure 3 8 shows the TRIG connector location on the NI PXI 8101 8102 Table 3...

Страница 50: ...f the following states ON steady PXI and onboard power is on and within regulation limits Blinking One of the PXI or onboard supplies is operating outside of the normal limits or is not functioning OF...

Страница 51: ...the memory hard drive time date and so on You can view these parameters in the BIOS setup To enter the BIOS setup reboot the NI PXI 8101 8102 and press Delete during the memory tests Refer to the Acc...

Страница 52: ...vices ordered by device type You can set the boot order using and Set the order by device type and set the order for the devices listed within the device type To boot from a different device without c...

Страница 53: ...ni com products How do I connect a VGA monitor to the NI PXI 8101 8102 A VGA to DVI I adapter part number 762559 01 is included with your kit You can use this adapter to connect a VGA monitor to the...

Страница 54: ...rive letter on the NI PXI 8101 8102 Upgrade Information How do I upgrade system memory You can change the amount of installed RAM on the NI PXI 8101 8102 by upgrading the DDR2 SO DIMM To upgrade the R...

Страница 55: ...I PXI 8101 8102 controller Windows only 250 GB or greater 2 5 in SATA hard drive upgrade 32 GB or greater 2 5 in SATA solid state hard drive upgrade How do I flash a new BIOS To update the BIOS follow...

Страница 56: ...and can boot from USB floppy drives A USB floppy drive will not work with Windows NT4 but will work with Windows 2000 or Windows XP Refer to the Boot Options section for more information A USB floppy...

Страница 57: ...t hangs note the last screen output that you saw for reference when consulting National Instruments technical support What has changed about the system Did you recently move the system Was there elect...

Страница 58: ...nitor attached the driver may have defaulted to the video output connector being disabled Press Ctrl Alt F1 to re enable the video display in Windows Press Ctrl Alt F4 to re enable a DVI display For m...

Страница 59: ...thod complete the following steps 1 Power off the chassis 2 Remove the controller from the chassis 3 Press and hold down push button switch SW2 for 2 to 3 seconds The switch location is shown in Figur...

Страница 60: ...CPU NI PXI 8102 Intel Dual Core Celeron T3100 1 9 GHz dual core processor 800 MHz FSB On die L2 cache 1 MB DDR2 RAM PC2 6400 1 GB Standard 4 GB Maximum Hard Drive 80 GB Serial ATA minimum or 4 GB Flas...

Страница 61: ...one controller expansion slot Compatibility Fully compatible with PXI specification Weight 0 645 kg 1 42 lb typical Voltage V Current Amps Typical Maximum 3 3 V 2 25 A 3 60 A 5 V 3 50 A 6 60 A 12 V 0...

Страница 62: ...ith a soft nonmetallic brush Make sure that the device is completely dry and free from contaminants before powering on the controller again Storage Environment Ambient temperature 40 to 65 C Tested in...

Страница 63: ...g 5 to 500 Hz 2 4 grms Tested in accordance with IEC 60068 2 64 Nonoperating test profile exceeds the requirements of MIL PRF 28800F Class 3 Note Specifications are subject to change without notice Sa...

Страница 64: ...ements of applicable European Directives as follows 2006 95 EC Low Voltage Directive safety 2004 108 EC Electromagnetic Compatibility Directive EMC Online Product Certification To obtain product certi...

Страница 65: ...Battery Replacement and Disposal Battery Directive This device contains a long life coin cell battery If you need to replace it use the Return Material Authorization RMA process or contact an authoriz...

Страница 66: ...rd Service Program Membership This program entitles members to direct access to NI Applications Engineers via phone and email for one to one technical support as well as exclusive access to on demand...

Страница 67: ...compatibility EMC and product safety You can obtain the DoC for your product by visiting ni com certification If you searched ni com and could not find the answers you need contact your local office o...

Страница 68: ...I 8101 8102 User Manual Glossary Symbol Prefix Value n nano 10 9 micro 10 6 m milli 10 3 k kilo 103 M mega 106 G giga 109 T tera 1012 Symbols Degrees Ohms Percent A A Amperes AC Alternating Current AS...

Страница 69: ...ductor A type of integrated circuit CompactPCI An adaptation of the PCI specification for industrial and or embedded applications that require a more robust mechanical form factor than desktop PCI Com...

Страница 70: ...s Parallel EEPROM Electronically Erasable Programmable Read Only Memory EMC Electromagnetic Compatibility EMI Electromagnetic interference EPP Enhanced Parallel Port expansion ROM An onboard EEPROM th...

Страница 71: ...nterrupt A means for a device to request service from another device interrupt level The relative priority at which a device can interrupt IRQ Interrupt request signal ISA Industry Standard Architectu...

Страница 72: ...al Component Interconnect The PCI bus is a high performance 32 bit or 64 bit bus with multiplexed address and data lines PCI Express Peripheral Component Interconnect Express A faster serialized versi...

Страница 73: ...an squared See also grms RTC Real Time Clock An electronic circuit that maintains the time of day and also can provide timing signals for timesharing operations S s Seconds slave A functional part of...

Страница 74: ...Glossary National Instruments Corporation G 7 NI PXI 8101 8102 User Manual V V Volts VGA Video Graphics Array The minimum video display standard for all PCs W W Watts...

Страница 75: ...onfiguration menu Parallel Port menu 2 9 Serial Port 0 menu 2 9 Trigger Router Configuration menu 2 10 USB configuration menu 2 8 Video Configuration menu 2 8 boot options configuring controller 4 2 B...

Страница 76: ...rd drive 2 20 documentation conventions used in manual ix how to use this documentation set ix NI resources B 1 related documentation x DRIVE LED 3 11 drivers 2 20 installation video 4 3 NI resources...

Страница 77: ...figuration switches 2 19 figure 2 20 RT installation and configuration 2 16 RT network settings figure 2 18 RT options menu 2 10 RT software installation 2 16 LabWindows CVI 1 5 LEDs front panel LEDs...

Страница 78: ...n and pinout figure 3 7 signals table 3 8 overview table 3 1 peripheral expansion overview table 3 1 physical specifications A 2 POWER OK LED 3 11 programming examples NI resources B 1 protective scre...

Страница 79: ...environment specifications A 3 super I O logic block 1 4 support technical B 1 system CMOS 2 15 system reset pushbutton 3 11 T technical support B 1 training and certification NI resources B 1 trigge...

Отзывы: