Appendix A
Specifications
©
National Instruments Corporation
A-7
NI PXI-1031/PXI-1031DC User Manual
Module cooling
System............................................. Forced air circulation (positive
pressurization) through a
101.1 CFM fan with
HIGH/AUTO speed selector
Intake .............................................. Bottom of chassis
Exhaust............................................ Along rear, right side,
and top of chassis
Power supply cooling
System............................................. Forced air circulation through
integrated fan
Intake .............................................. Front and left side of chassis
Exhaust............................................ Rear side of chassis
Environmental
Operating location.................................. Indoor use
Maximum altitude .................................. 2,000 m
Installation Category .............................. II
Pollution Degree .................................... 2
Operating Environment
Ambient temperature range.................... 0 to 50 °C
(Tested in accordance
with IEC-60068-2-1 and
IEC-60068-2-2.)
Storage Environment
Ambient temperature range.................... –20 to 70 °C
(Tested in accordance
with IEC-60068-2-1 and
IEC-60068-2-2.)
Relative humidity range ......................... 5 to 95%, noncondensing
(Tested in accordance with
IEC-60068-2-56.)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com