background image

4

|

ni.com

|

PCI/PXI/PCIe-6509 User Guide and Specifications

Note

The following statements contain important EMC information needed before 

installing and using this product:

This product is intended for use in industrial locations. As a result, this product may cause 
interference if used in residential areas. Such use must be avoided unless the user takes 
special measures to reduce electromagnetic emissions to prevent interference to the 
reception of radio and television broadcasts.

This product may become more sensitive to electromagnetic disturbances in the operational 
environment when test leads are attached or when connected to a test object.

Emissions that exceed the regulatory requirements may occur when this product is 
connected to a test object.

Changes or modifications not expressly approved by National Instruments could void the 
user’s authority to operate the hardware under the local regulatory rules.

Operate this product only with shielded cables and accessories.

Configuration

The NI PCI/PXI/PCIe-6509 devices are fully compliant with the 

PCI Local Bus Specification 

Revision 2.2

, the 

PXI Hardware Specification Revision 2.1

, and the 

PCI Express 

Electromechanical Specification Revision 1.1

, respectively. The PCI/PXI/PCIe system 

automatically allocates all device resources, including the base address and interrupt level. The 
device base address is mapped into PCI memory space. It is not necessary to perform 
configuration steps after the system powers up.

Before installing the NI 6509 device, you must install the software you plan to use with the 
device. Refer to the software documentation for configuration instructions.

After you install the software and the NI 6509 device, the device appears under the 

Devices and 

Interfaces

 branch of the Measurement & Automation Explorer (MAX) configuration tree.

If the NI 6509 does not appear in MAX, use the following troubleshooting guidelines:

Verify that you are using the correct version of the NI-DAQmx driver software (version 7.1 
or later for the NI PCI/PXI-6509 and version 9.2 or later for the PCIe-6509). To download 
the most recent National Instruments drivers, visit 

ni.com

/

downloads

.

Press <F5> to refresh the MAX window, or close and reopen MAX.

Restart the computer.

Power off and unplug the computer or chassis, and install the device in a different slot. 
Refer to the 

DAQ Getting Started

 guides for installation instructions and safety guidelines.

(PCI-6509 only)

 You must install the PCI-6509 into a slot that provides 3.3 V. Check that 

the 3.3 V LED (reference designator 

DS1

—located on the visible edge of the underside of 

the installed device) is lit. If not, check that the PC motherboard provides 3.3 V to the PCI 
bus.

Содержание PCI-6509

Страница 1: ...timer Contents Safety Information 2 Electromagnetic Compatibility Guidelines 3 Configuration 4 Programming Devices in Software 5 Functional Overview 5 I O Connector 6 Pin Assignments 7 Signal Descript...

Страница 2: ...tion of the DIO device Do not operate the DIO device in an explosive atmosphere or where there may be flammable gases or fumes If you need to clean the DIO device use a soft nonmetallic brush Make sur...

Страница 3: ...easurements performed in the building installation at the distribution level This category refers to measurements on hard wired equipment such as equipment in fixed installations distribution boards a...

Страница 4: ...system automatically allocates all device resources including the base address and interrupt level The device base address is mapped into PCI memory space It is not necessary to perform configuration...

Страница 5: ...plication Refer to the DAQ Getting Started guides for more information about NI DAQmx The NI PCI PXI 6509 uses NI DAQmx 7 1 or later whereas the NI PCIe 6509 requires NI DAQmx 9 2 or later To locate e...

Страница 6: ...NI 6509 provides access to 96 digital inputs and outputs Use this connector to connect to external devices such as solid state relays SSRs and LEDs For easy connection to the digital I O connector use...

Страница 7: ...al Instruments 7 Pin Assignments SH100 100 F Connector Figure 3 shows the pin assignments for the SH100 100 F cable when you connect it to the NI 6509 device The naming convention for each pin is PX Y...

Страница 8: ...9 1 P6 1 P9 2 P6 2 P9 3 P6 3 P9 4 P6 4 P9 5 P6 5 P9 6 P6 6 P9 7 P6 7 P10 0 P7 0 P10 1 P7 1 P10 2 P7 2 P10 3 P7 3 P10 4 P7 4 P10 5 P7 5 P10 6 P7 6 P10 7 P7 7 P11 0 P8 0 P11 1 P8 1 P11 2 P8 2 P11 3 P8 3...

Страница 9: ...P1 2 P1 3 P1 4 P1 5 P1 6 P1 7 P2 0 P2 1 P2 2 P2 3 P2 4 P2 5 P2 6 P2 7 GND P3 1 P3 2 P3 4 P3 5 P3 6 P3 7 P3 0 P3 3 P4 0 P4 1 P4 2 P4 3 P4 4 P4 5 P4 6 P4 7 P5 0 P5 1 P5 2 P5 3 P5 4 P5 5 P5 6 P5 7 49 50...

Страница 10: ...0 33 35 37 39 41 43 45 47 P0 7 0 Bi directional data lines for port 0 P0 7 P0 0 34 36 38 40 42 44 46 48 P3 7 0 Bi directional data lines for port 3 P3 7 P3 0 49 99 5 V supply 5 volts provides 5 V powe...

Страница 11: ...d the current requirements of the load Do not exceed the output limits of the DAQ device NI has several signal conditioning solutions for digital applications that require high current drive If you co...

Страница 12: ...he DIO lines that are configured for input To use MAX to configure the I O pull resistor select the device and click the Properties button Refer to the software documentation for information about how...

Страница 13: ...rge counter electromotive force may occur at switching time because of the energy stored in the inductive load These flyback voltages can damage the outputs and or the power supply To limit these flyb...

Страница 14: ...xamples of connecting the NI 6509 to a relay that does not require more than 24 mA of current Figure 8 NI 6509 Sinking Connection Example 24 mA Figure 9 NI 6509 Sourcing Connection Example 24 mA Drivi...

Страница 15: ...not connect the 5 V power pin directly to ground or to any other voltage source on any other device Doing so may permanently damage the NI 6509 device and the computer Disk Drive Power Connector PCIe...

Страница 16: ...computer 2 Remove the computer cover 3 Attach the PC disk drive power connector to the disk drive power connector on the PCIe 6509 as Figure 13 shows Figure 13 Connecting to the Disk Drive Power Conne...

Страница 17: ...ecified timing interval The NI 6509 samples the input signal on each rising edge of the sample clock but the NI 6509 recognizes a change in the input signal only if the input signal maintains its new...

Страница 18: ...LabVIEW or other NI application development environments ADEs Change Detection You can program the NI 6509 to send an interrupt when a change occurs on any input line The NI 6509 can monitor changes o...

Страница 19: ...2 After receiving notification of a change you can read the port to determine the current values of all eight lines However you cannot read the lines that are configured for change detection until a c...

Страница 20: ...essories Caution This NI product must be operated with shielded cables and accessories to ensure compliance with the Electromagnetic Compatibility EMC requirements defined in the Specifications sectio...

Страница 21: ...5 25 V 1A maximum Note The voltage at the I O connector depends on the amount of current drawn from the NI 6509 Digital I O Number of channels 96 I O Compatibility PCI PXI 6509 TTL CMOS single ended G...

Страница 22: ...use the following equation to determine the power consumption on a 5 V rail In the equation j is the number of channels you are using to source current Digital Logic Levels PCIe 6509 Input Signals Le...

Страница 23: ...nstalled the current at the 5 V terminal is supplied by an external power source In this case the current at the 5 V terminal can be up to 1 A Negative going threshold VT 0 8 V Delta VT hysteresis VT...

Страница 24: ...3 4 oz Environmental The NI 6509 device is intended for indoor use only Operating Environment Ambient temperature range 0 C to 55 C Relative humidity range 10 to 90 noncondensing Altitude 2 000 m at 2...

Страница 25: ...missions FCC 47 CFR Part 15B Class A emissions ICES 003 Class A emissions Note For the standards applied to assess the EMC of this product refer to the Online Product Certification section Note For EM...

Страница 26: ...ters National Instruments WEEE initiatives and compliance with WEEE Directive 2002 96 EC on Waste and Electronic Equipment visit ni com environment weee Where to Go Next The following documents contai...

Страница 27: ...ces The NI website is your complete resource for technical support At ni com support you have access to everything from troubleshooting and application development self help resources to email and pho...

Отзывы: