![National Instruments NI VISION PCI-8254R Скачать руководство пользователя страница 7](http://html2.mh-extra.com/html/national-instruments/ni-vision-pci-8254r/ni-vision-pci-8254r_quick-start-manual_3498747007.webp)
© National Instruments Corporation
7
NI PCI-8254R Quick Start Guide
Caution
Do not connect the NI 8254R isolated power to a source less than 5 VDC or
greater than 30 VDC. Doing so could damage the NI 8254R device.
To connect power for the isolated outputs to the NI 8254R, refer to
Figures 2 through 6 while completing the following steps:
1.
If you are using the NI desktop power supply, remove the 4-position
power connector connected to the power supply, shown in Figure 2.
a.
Reconnect the wire that was connected to the V position on the
4-position power connector to the V position on the 2-position
isolated outputs power connector, shown in Figure 3.
b.
Reconnect the wire that was connected to the C position on the
4-position power connector to the C position on the 2-position
isolated outputs power connector, shown in Figure 3.
Figure 2. Removing the 4-Position Power Connector from the Power Supply
Figure 3. Connecting the 2-Position Power Connector to the Power Supply
2.
Plug the 2-position isolated outputs power connector from the power
supply into the power receptacle on the NI 8254R.
1
4-Position Power Connector
2
V Position
3
C Position
4
Power Supply Wire and Optional Ferrule
1
2-Position Isolated Outputs Power Connector
2
C Position
3
V Position
4
Power Supply Wire and Optional Ferrule
2
3
4
1
2
3
4
1