NI PCI-8254R Quick Start Guide

If the device is rated for use with hazardous voltages (>30 V

rms

, 42.4 V

pk

or 60 V

dc

), it may require a safety earth-ground connection wire. Refer to 

the device specifications for maximum voltage ratings.

Because of the danger of introducing additional hazards, do not install 
unauthorized parts or modify the device. Use the device only with the 
chassis, modules, accessories, and cables specified in the installation 
instructions. All covers and filler panels must be installed while operating 
the device.

Do not operate the device in an explosive atmosphere or where flammable 
gases or fumes may be present. Operate the device only at or below the 
pollution degree stated in the specifications. Pollution consists of any 
foreign matter—solid, liquid, or gas—that may reduce dielectric strength 
or surface resistivity. The following is a description of pollution degrees.

Pollution Degree 1—No pollution or only dry, nonconductive 
pollution occurs. The pollution has no effect.

Pollution Degree 2—Normally only nonconductive pollution occurs. 
Occasionally, nonconductive pollution becomes conductive because of 
condensation.

Pollution Degree 3—Conductive pollution or dry, nonconductive 
pollution occurs. Nonconductive pollution becomes conductive 
because of condensation.

Clean the device and accessories by brushing off light dust with a soft, 
nonmetallic brush. Remove other contaminants with a stiff, nonmetallic 
brush. The unit must be completely dry and free from contaminants before 
returning it to service.

You must insulate signal connections for the maximum voltage for which 
the device is rated. Do not exceed the maximum ratings for the device. 
Remove power from signal lines before connection to or disconnection 
from the device. 

Caution

National Instruments measurement products may be classified as either 

Measurement Category I or II. Operate products at or below the Measurement Category 
level specified in the hardware specifications.

Measurement Category

1

: Measurement circuits are subjected to working 

voltages

2

 and transient stresses (overvoltage) from the circuit to which they 

are connected during measurement or test. Measurement Category 
establishes standardized impulse withstand voltage levels that commonly 

1   

Measurement Categories as defined in electrical safety standard IEC 61010-1.

2   

Working voltage is the highest rms value of an AC or DC voltage that can occur across any particular insulation.

Содержание NI VISION PCI-8254R

Страница 1: ...I Vision Acquisition Software 8 0 or later NI Vision Acquisition Software Release Notes Computer running Windows 2000 XP with at least one PCI slot IEEE 1394 camera IEEE 1394a cable Cable for digital...

Страница 2: ...formation Caution The following paragraphs contain important safety information you must follow when installing and operating the device Do not operate the device in a manner not specified in the docu...

Страница 3: ...ecomes conductive because of condensation Pollution Degree 3 Conductive pollution or dry nonconductive pollution occurs Nonconductive pollution becomes conductive because of condensation Clean the dev...

Страница 4: ...ts on hard wired equipment such as equipment in fixed installations distribution boards and circuit breakers Other examples are wiring including cables bus bars junction boxes switches socket outlets...

Страница 5: ...To protect yourself and the computer from electrical hazards the computer must remain unplugged until the installation is complete 3 Remove the computer cover to expose the expansion slots 4 Choose an...

Страница 6: ...puter The NI 8254R is now installed and your camera is connected Refer to Figure 1 for information about placement of the connectors on the NI 8254R Figure 1 NI 8254R Connectors Wiring Isolated Output...

Страница 7: ...tor to the V position on the 2 position isolated outputs power connector shown in Figure 3 b Reconnect the wire that was connected to the C position on the 4 position power connector to the C position...

Страница 8: ...e around the ferrite two times as shown in Figures 4 and 5 Figure 4 Installing a Ferrite Connector on the Power Supply Cable Figure 5 Closed Ferrite on the Power Supply Cable 4 Plug the power supply c...

Страница 9: ...supply you can optionally use 0 75 mm2 18 AWG ferrules according to the manufacturer specifications to terminate the wires leading to the 2 position power connector shown in Figure 7 Ferrules are avai...

Страница 10: ...nize the device and assign resources to it Use Measurement Automation Explorer MAX the National Instruments configuration utility to configure the IEEE 1394 camera connected to the NI 8254R for acquis...

Страница 11: ...hannels 10 Output voltage range 0 V to 5 V 1 The bus power specification assumes that power is provided to the NI 8254R device from the host computer power supply via the ATX power connector If power...

Страница 12: ...lse rate 100 kHz Minimum pulse detected 10 s Reverse polarity protection Yes 30 V Isolated Current Sourcing Outputs Number of channels 4 On state voltage range 5 V to 30 V maximum Maximum on state vol...

Страница 13: ...not use the NI 8254R for connection to signals within Measurement Categories II III or IV Measurement Category I Approved at altitudes up to 2 000 m Safety The NI 8254R is designed to meet the require...

Страница 14: ...73 23 EEC Low Voltage Directive safety 89 336 EEC Electromagnetic Compatibility Directive EMC Note Refer to the Declaration of Conformity DoC for this product for any additional regulatory compliance...

Страница 15: ...has offices located around the world to help address your support needs For telephone support in the United States create your service request at ni com support and follow the calling instructions or...

Страница 16: ...l Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer to the ap...

Отзывы: