National Instruments
17
8-Slot NI PXIe-1082 Backplane Installation Guide
Connectors J2, J3, and J4
Use these connectors for three thermistors to monitor the card-cage
temperature. You can use signal OVERTEMP# on J37 as an alarm
indicating when the card-cage temperature exceeds 90 °C when used in
conjunction with the four thermistors.
Note
Use a Sensor Scientific KWM502C-6 or similar thermistor with these connectors.
Note
The mating connector for J2, J3, and J4 is Molex part number 50-57-9402.
Backplane Specifications
Size......................................................... 3U-sized; one system slot
(with three system expansion
slots) and 7 peripheral slots.
Compliant with IEEE 1101.10
mechanical packaging.
PXI Express specification
compliant.
Accepts both PXI Express and
CompactPCI (PICMG 2.0 R 3.0)
3U modules.
Backplane bare-board material .............. UL 94 V-0 Recognized
Backplane connectors ............................ Conforms to IEC 917 and
IEC 1076-4-101, and are
UL 94 V-0 rated
Table 3.
Connector J35 Pin Descriptions
Connector
Pin
Signal
Description
1
PWRBTN#
Input to system
slot J18—pin F2
2
GND
Ground plane
3
LED1
J37—pin 14
4
LED2
J37—pin 15
1
2
3
4
J35