Appendix A
Specifications
A-2
ni.com
Operating Environment
Ambient temperature range
Relative humidity range..........................10% to 90%, noncondensing
(Tested in accordance with
IEC-60068-2-56.)
Altitude ...................................................2,000 m (at 25 °C ambient
temperature)
Pollution Degree .....................................2
For indoor or enclosed area use only.
Caution
Clean the PXI-8185 with a soft nonmetallic brush. Make sure that the device is
completely dry and free from contaminants before returning it to service.
Storage Environment
Ambient temperature range ....................–20 to 65 °C (Tested in
accordance with IEC-60068-2-1
and IEC-60068-2-2.)
Relative humidity range..........................5% to 95% noncondensing
(Tested in accordance with
IEC-60068-2-56.)
Chassis
NI PXI-8185
PXI-1000B
5–50 °C
PXI-1002
5–40 °C
PXI-1006
5–50 °C
PXI-1010
5–35 °C
PXI-1011
5–50 °C
PXI-1042
5–50 °C
PXI-1045
5–55 °C