Chapter 3
Hardware Overview
©
National Instruments Corporation
3-7
Figure 3-7.
Inside-Region Analog Triggering Mode
In high-hysteresis analog triggering mode, the trigger is generated when the
signal value is greater than
highValue
, with the hysteresis specified by
lowValue
,
as shown in Figure 3-8.
Figure 3-8.
High-Hysteresis Analog Triggering Mode
In low-hysteresis analog triggering mode, the trigger is generated when the
signal value is less than
lowValue
, with the hysteresis specified by
highValue
,
as shown in Figure 3-9.
Figure 3-9.
Low-Hysteresis Analog Triggering Mode
highValue
Trigger
lowValue
highValue
Trigger
lowValue
highValue
Trigger
lowValue