In this example, a breakpoint generates and then is re-enabled 5,000 counts
from where the move starts. The following code examples are designed to
illustrate the relative breakpoint algorithm only. These examples are not
complete.
Figure 12-7.
Relative Position Breakpoint with RTSI Using LabVIEW
C/C++ Code
The following example code is not necessarily complete, and may
not compile if copied exactly. Refer to the
examples
folder on the
NI-Motion CD for files that are complete and compile as is.
//
Main Function
void main(void)
{
u8
boardID;//
Board identification number
u8
axis;//
Axis number
u16
csr = 0;//
Communication status register
u16
axisStatus;//
Axis status
i32
breakpointPosition = 5000;
//Variables for modal error handling
u16
commandID;//
The commandID of the function
u16
resourceID;//
The resource ID
i32
errorCode;//
Error code
///////////////////////////////
//
Set the board ID
boardID = 1;
1
Select Signal
2
Configure Breakpoint
3
Load Breakpoint Position
4
Enable Breakpoint Output
5
Read per Axis Status
6
Motion Error Handler