background image

© 

National Instruments Corporation

15

NI-DAQmx for NI WLS/ENET-9163 Getting Started Guide

Refer to the 

NI WLS/ENET-9163 User Guide and Specifications

 and your 

C Series I/O module user guide for information about how to use your 
NI WLS/ENET-9000 Series device.

Programming Examples

NI-DAQmx includes example programs to help you get started developing an 
application. Modify example code and save it in an application, or use examples 
to develop a new application or add example code to an existing application.

To locate LabVIEW, LabWindows/CVI, Measurement Studio, Visual Basic, and 
ANSI C examples, go to 

ni.com/info

 and enter the info code 

daqmxexp

For additional examples, refer to 

zone.ni.com

.

To run examples without hardware installed, use an NI-DAQmx simulated device. 
In MAX, select 

Help»Help Topics»NI-DAQmx»MAX Help for NI-DAQmx

 

for information about creating NI-DAQmx simulated devices.

Troubleshooting

If you have problems installing your software, go to 

ni.com/support/daqmx

For hardware troubleshooting, go to ni.com/support and enter your device name, 
or go to 

ni.com/kb

.

If you think you have damaged your device and need to return your National 
Instruments hardware for repair or device calibration, refer to 

ni.com/info

 and 

enter the info code 

rdsenn

 to learn how to begin the Return Merchandise 

Authorization (RMA) process.

Содержание NI ENET-9000 Series

Страница 1: ... that the device is working properly Refer to the NI WLS ENET 9163 User Guide and Specifications and your C Series I O module user guide for information about how to use your NI WLS ENET 9000 Series device You must be an Administrator to install NI software and devices on your computer Check for documentation updates at ni com manuals Pinouts and User Guides All NI DAQmx devices have a PDF user gu...

Страница 2: ...k and complete the instructions including rebooting the computer For troubleshooting instructions use the Hardware Installation Configuration Troubleshooter at ni com support install Step 2 Unpack and Set Up the Device The NI C Series I O module and the NI WLS ENET 9163 carrier are packaged separately Remove the packaging and inspect the devices Contact NI if the components appear damaged Do not i...

Страница 3: ...e any protective covers from the C Series I O module connector 2 Align the C Series I O module with the NI WLS ENET 9163 carrier 3 Squeeze the latches and insert the C Series I O module into the NI WLS ENET 9163 carrier Figure 1 C Series I O Module Installation 1 C Series I O Module 2 NI WLS ENET 9163 Carrier N A T IO N A L IN S T R U M E N T S RESET W LS LI N K LIN K A CT GN D GN D PR0 PR1 10 100...

Страница 4: ... the supplied antenna as shown in Figure 3 Figure 3 NI WLS 9163 Carrier Antenna Assembly N A T IO N A L IN S T R U M E N T S RES ET LINK ACT GND GND PR0 PR1 10 1 00 INPU T 9 30 V 4 5 W MAX V C NI WL S 9 163 802 11g C Ser ies Car rier WLS LINK ACT IVE STAT US P0W ER WL S LIN K PO WE R AC TIV E ST AT US ST AT US PO WE R ACTIV E RESET LIN K A CT GN D GN D PR0 PR1 10 100 INP UT 9 3 0V 4 5 W MA X V C W...

Страница 5: ...pter or other 9 30 VDC power source The POWER and STATUS LEDs light The POWER LED will light as long as power is being supplied to the NI WLS ENET 9000 Series device Refer to the NI WLS ENET 9163 User Guide and Specifications for information about the LEDs on the NI WLS ENET 9163 chassis Step 3 Discover the Device To discover the device complete the following steps 1 Launch Measurement Automation ...

Страница 6: ...ow and click Add Selected Devices to add the device to MAX The device will be listed under Network Devices in the configuration tree If your device does not appear in Available Devices wait until the POWER LED on the device is green and the STATUS LED turns off then click Refresh List If the device does not appear try the following If you connected your device directly to your computer ensure your...

Страница 7: ...3 If your device still does not appear contact your system administrator to confirm that the network is working and that a firewall is not interfering with discovery For more information about the ports used for discovery and communication refer to the NI WLS ENET 9163 User Guide and Specifications Troubleshooting Device Connectivity If your device becomes disconnected from the network try the fol...

Страница 8: ...owing information in the General Network Settings section Hostname The default is WLS serial number or ENET serial number This field is limited to 32 characters Comment Use this field to enter notes such as the device location NI WLS 9000 Series Only Wireless Configuration To configure your NI WLS 9000 Series device for connection to the wireless network select the Wireless Configuration tab and c...

Страница 9: ...e IP Address Subnet Mask Gateway DNS Server fields are automatically populated after you save your settings Otherwise ask your network administrator for the correct settings Select or enter the name of the wireless network to which you want to connect in the SSID Service Set Identifier field Select Infrastructure or Ad Hoc from the Wireless Mode pull down menu ...

Страница 10: ...e and Password fields Ask your network administrator for the correct settings c Click Save Settings The Apply Changes alert opens Click OK The WLS LINK LED lights on the device indicating a connected and authenticated network link d If Link Status Wireless in the Device Information section of the Network Config tab is listed as Down click the Refresh button a few times Link Status Wireless must be...

Страница 11: ...cable select the Wired Configuration tab for NI WLS 9000 Series devices or the Configuration tab for NI ENET 9000 Series devices and complete the following steps a Select DHCP Link Local DHCP Static or Link Local from the Obtain IP Address Through pull down menu If you selected DHCP from the Obtain IP Address Through pull down menu the IP Address Subnet Mask Gateway DNS Server fields are automatic...

Страница 12: ...ignal lines to the terminal block or accessory terminals to your device The following table lists the different ways to access device pin assignments pinouts Location How to Access Pinout MAX Right click the device name under Network Devices and select Device Pinouts Right click the device name under Network Devices and select Help Online Device Documentation A browser window opens to ni com manua...

Страница 13: ...terfaces Network Devices 2 Right click your device and select Test Panels to open a test panel for the selected device 3 Click the tabs at the top and Start to test the device functions or Help for operating instructions If the test panel displays an error message refer to ni com support 4 Click Close to exit the test panel ni com manuals Refer to the device documentation user guide for your C Ser...

Страница 14: ... data acquisition in your application software refer to the tutorials listed in the following table Application Tutorial Location LabVIEW Go to Help Search the LabVIEW Help Next go to Getting Started with LabVIEW Getting Started with DAQ Taking an NI DAQmx Measurement in LabVIEW LabWindows CVI Go to Help Contents Next go to Using LabWindows CVI Data Acquisition Taking an NI DAQmx Measurement in La...

Страница 15: ...isual Basic and ANSI C examples go to ni com info and enter the info code daqmxexp For additional examples refer to zone ni com To run examples without hardware installed use an NI DAQmx simulated device In MAX select Help Help Topics NI DAQmx MAX Help for NI DAQmx for information about creating NI DAQmx simulated devices Troubleshooting If you have problems installing your software go to ni com s...

Страница 16: ...y names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products technology refer to the appropriate location Help Patents in your software the patents txt file on your media or the National Instruments Patent Notice at ni com patents Worldwide Technical Support For support information refer to the Technical Support Information...

Отзывы: