NI CVS-1458 Getting Started Guide

Optional Equipment

National Instruments offers the following products for use with the NI CVS-1458:

24 VDC, 1.25 A Desktop Power Supply (part number 782032-01)

NI PoE Power Supply to power the Power over Ethernet (PoE) ports (part number 

783307-01 for DIN rail version or part number 783308-01 for desktop version)

44-pin D-SUB cable for digital I/O

44-pin D-SUB male to pigtail cable (part number 156083-03 for 3 meter cable)

44-pin D-SUB male to 44-position D-SUB female cable (part number 156084-03 for 

3 meter cable or part number 156084-0R5 for 0.5 meter cable)

NI CVS I/O Accessory

Note

This accessory is unshielded.

CVS I/O Accessory and 3 meter 44-pin D-SUB male to 44-position D-SUB female 

cable (part number 783327-01)

CVS I/O Accessory and 0.5 meter 44-pin D-SUB male to 44-position D-SUB female 

cable (part number 783328-01)

DIN Rail Kit (part number 781740-01)

10-position modular plug to 9-pin D-sub serial cable for RS-485 or RS-232 (part number 

182845-01 for 1 meter cable, part number 182845-02 for 2 meter cable, or part number 

182845-03 for 3 meter cable)

Safety Information

Caution

The following paragraphs contain important safety information you 

must

 

follow when installing and operating the device.

Do 

not

 operate the device in a manner not specified in the documentation. Misuse of the device 

may result in a hazard and may compromise the safety protection built into the device. If the 

device is damaged, turn it off and do 

not

 use it until service-trained personnel can check its 

safety. If necessary, return the device to National Instruments for repair.

Keep away from live circuits. Do 

not

 remove equipment covers or shields unless you are trained 

to do so. If signal wires are connected to the device, hazardous voltages can exist even when the 

equipment is turned off. To avoid a shock hazard, do 

not

 perform procedures involving cover or 

shield removal unless you are qualified to do so. Disconnect all field power prior to removing 

covers or shields.

Because of the danger of introducing additional hazards, do 

not

 install unauthorized parts or 

modify the device. Use the device only with the chassis, modules, accessories, and cables 

Содержание NI CVS-1458

Страница 1: ...T Ethernet cable per GigE Vision camera One CAT 5 10 100Base TX CAT 5e or CAT 6 1000Base T Ethernet cable to connect the device to a network Note A CAT 5e or CAT 6 1000Base T Ethernet cable is requir...

Страница 2: ...182845 01 for 1 meter cable part number 182845 02 for 2 meter cable or part number 182845 03 for 3 meter cable Safety Information Caution The following paragraphs contain important safety information...

Страница 3: ...You must insulate signal connections for the maximum voltage for which the device is rated Do not exceed the maximum ratings for the device Remove power from signal lines before connection to or disco...

Страница 4: ...gging in or unplugging any connector Ground the unit to minimize the possibility of static electricity damage Complete the following sections to wire power to the NI CVS 1458 connect cameras and conne...

Страница 5: ...the negative and positive leads of the power source approximately 50 to 75 mm 2 to 3 in from the end of the power input wires as shown in Figure 3 Figure 3 Installing a Ferrite on the Power Leads 1 VG...

Страница 6: ...l screw to 0 2 to 0 25 N m 1 8 to 2 2 lb in of torque 6 Install the power connector plug into the SYSTEM power receptacle on the NI CVS 1458 chassis and tighten the connector screws to 0 4 N m 3 5 lb...

Страница 7: ...of the isolated outputs power source to the CISO terminal of the power connector plug and tighten the terminal screw to 0 2 to 0 25 N m 1 8 to 2 2 lb in of torque 6 Connect the positive lead of the Po...

Страница 8: ...illuminate 3 Verify the ACTIVITY LINK LED is lit Acquiring an Image in MAX 1 Open Measurement Automation Explorer MAX 2 In the Configuration Pane expand Devices and Interfaces 3 Select the camera you...

Страница 9: ...O 4 TTL 1 Bidirectional TTL I O 5 GND Digital ground reference for TTL and differential I O 6 TTL 2 Bidirectional TTL I O 7 TTL 3 Bidirectional TTL I O 8 GND Digital ground reference for TTL and diffe...

Страница 10: ...pose isolated input 33 CISO Common ground reference for isolated inputs and outputs 34 Iso In 2 General purpose isolated input 35 Iso In 3 General purpose isolated input 36 CISO Common ground referenc...

Страница 11: ...n You can also access context help within Vision Builder AI by clicking the Show Context Help button on the Vision Builder AI toolbar Examples of Vision Builder AI inspections are installed to the Vis...

Страница 12: ...e is your complete resource for technical support At ni com support you have access to everything from troubleshooting and application development self help resources to email and phone assistance fro...

Отзывы: