manualshive.com logo in svg
background image

NI CVS-1458 Getting Started Guide

|

© National Instruments

|

11

Where to Go Next

The following documents and resources contain information you may find helpful as you use the 

NI CVS-1458 in an application. Refer to the National Instruments Product Manuals Library at 

ni.com/manuals

 for the most recent versions of product documentation.

NI CVS-1458 Specifications

—Contains detailed specifications for the NI CVS-1458.

NI CVS-1458 User Manual

—Contains connector pinouts, configuration information, 

mounting information, and answers to common troubleshooting questions.

NI CVS I/O Accessory User Manual

—Contains installation and operation instructions for 

the CVS I/O Accessory.

Additional Resources for Vision Builder AI Users

Refer to the 

NI Vision Builder for Automated Inspection Tutorial

 to learn how to perform basic 

machine vision techniques using Vision Builder AI. You can access the 

NI Vision Builder for 

Automated Inspection Tutorial

 and other documentation by selecting 

Start»All Programs»

National Instruments»Vision Builder AI»Documentation

. You can also access context help 

within Vision Builder AI by clicking the 

Show Context Help

 button on the Vision Builder AI 

toolbar.

Examples of Vision Builder AI inspections are installed to the 

<Vision Builder AI>\

Examples

 directory, where 

<Vision Builder AI>

 is the location Vision Builder AI is 

installed.

Additional Resources for LabVIEW Users

Documentation for LabVIEW and the LabVIEW FPGA Module is available from the 

Help

 

menu on the LabVIEW toolbar. You can access documentation for the NI Vision Development 

Module, NI-IMAQdx, and NI-IMAQ I/O by selecting 

Start»All Programs»National 

Instruments»Vision»Documentation

.

Documentation for the MAX configuration software is available from the 

Help

 menu on the 

MAX toolbar. Specific information about using MAX with NI Vision hardware is available by 

selecting 

Help»Help Topics»NI Vision»NI-IMAQdx

.

National Instruments Example Finder—LabVIEW contains an extensive library of VIs and 

example programs. To access the NI Example Finder, open LabVIEW and select 

Help»Find 

Examples

.

Visit the NI Developer Zone at 

ni.com/zone

 for the latest example programs, tutorials, 

technical presentations, and a community area where you can share ideas, questions, and source 

code with developers around the world.

Содержание NI CVS-1458

Страница 1: ...T Ethernet cable per GigE Vision camera One CAT 5 10 100Base TX CAT 5e or CAT 6 1000Base T Ethernet cable to connect the device to a network Note A CAT 5e or CAT 6 1000Base T Ethernet cable is requir...

Страница 2: ...182845 01 for 1 meter cable part number 182845 02 for 2 meter cable or part number 182845 03 for 3 meter cable Safety Information Caution The following paragraphs contain important safety information...

Страница 3: ...You must insulate signal connections for the maximum voltage for which the device is rated Do not exceed the maximum ratings for the device Remove power from signal lines before connection to or disco...

Страница 4: ...gging in or unplugging any connector Ground the unit to minimize the possibility of static electricity damage Complete the following sections to wire power to the NI CVS 1458 connect cameras and conne...

Страница 5: ...the negative and positive leads of the power source approximately 50 to 75 mm 2 to 3 in from the end of the power input wires as shown in Figure 3 Figure 3 Installing a Ferrite on the Power Leads 1 VG...

Страница 6: ...l screw to 0 2 to 0 25 N m 1 8 to 2 2 lb in of torque 6 Install the power connector plug into the SYSTEM power receptacle on the NI CVS 1458 chassis and tighten the connector screws to 0 4 N m 3 5 lb...

Страница 7: ...of the isolated outputs power source to the CISO terminal of the power connector plug and tighten the terminal screw to 0 2 to 0 25 N m 1 8 to 2 2 lb in of torque 6 Connect the positive lead of the Po...

Страница 8: ...illuminate 3 Verify the ACTIVITY LINK LED is lit Acquiring an Image in MAX 1 Open Measurement Automation Explorer MAX 2 In the Configuration Pane expand Devices and Interfaces 3 Select the camera you...

Страница 9: ...O 4 TTL 1 Bidirectional TTL I O 5 GND Digital ground reference for TTL and differential I O 6 TTL 2 Bidirectional TTL I O 7 TTL 3 Bidirectional TTL I O 8 GND Digital ground reference for TTL and diffe...

Страница 10: ...pose isolated input 33 CISO Common ground reference for isolated inputs and outputs 34 Iso In 2 General purpose isolated input 35 Iso In 3 General purpose isolated input 36 CISO Common ground referenc...

Страница 11: ...n You can also access context help within Vision Builder AI by clicking the Show Context Help button on the Vision Builder AI toolbar Examples of Vision Builder AI inspections are installed to the Vis...

Страница 12: ...e is your complete resource for technical support At ni com support you have access to everything from troubleshooting and application development self help resources to email and phone assistance fro...

Отзывы: