background image

1.

Launch MAX on the host computer.

2.

Expand 

Remote Systems

 in the configuration tree and locate your system.

3.

Select your target.

Tip

 

MAX lists the system under the model number followed by the serial

number, such as NI-CRIO-9147-1856AAA.

Setting a System Password

Complete the following steps to set a system password.

Note

 

The default username for the NI 9147 is 

admin

. There is no default password

for the NI 9147, so you must leave the password field blank when logging in until
you set a system password.

1.

Right-click your system and select 

Web Configuration

.

The NI Web-Based Configuration and Monitoring utility opens in your default browser
and is where you set the password. If you have not installed Microsoft Silverlight,
NI Web-based Configuration & Monitoring prompts you to do so.

2.

Enter a unique name for your system in the 

Hostname

 field.

3.

Click the 

Security Configuration

 icon.

4.

Click 

Login

.

5.

In the 

Login

 dialog box, enter the username 

admin

 and leave the password field blank.

6.

Click 

OK

.

7.

Click 

Change Password

.

8.

Enter and re-enter a new password.

9.

Click 

OK

.

10. Click 

Save

.

11. Click 

OK

 to confirm you are changing the password.

Caution

 

NI cannot recover lost system passwords. If you forget the password,

you must contact NI and reformat the controller.

Installing Software on the NI 9147

Complete the following steps to install software on the NI 9147.
1.

In MAX, expand your system under Remote Systems.

2.

Right-click 

Software

.

3.

Select 

Add/Remove Software

 to launch the LabVIEW Real-Time Software Wizard.

Tip

 

You must log in if you set a system password.

4.

Select the recommended software set for your LabVIEW and NI-RIO Device Drivers
versions.

5.

Click 

Next

.

NI 9147 Getting Started Guide

  | 

© National Instruments

  | 

9

Содержание NI 9147

Страница 1: ...ines for Hazardous Locations The NI 9147 is suitable for use in Class I Division 2 Groups A B C D T4 hazardous locations Class I Zone 2 AEx nA IIC T4 and Ex nA IIC T4 hazardous locations and nonhazard...

Страница 2: ...Caution The system shall only be used in an area of not more than Pollution Degree 2 as defined in IEC 60664 1 Caution The system shall be mounted in an ATEX IECEx certified enclosure with a minimum i...

Страница 3: ...designing selecting and installing measurement probes and cables to ensure that the desired EMC performance is attained Preparing the Environment Ensure that the environment in which you are using th...

Страница 4: ...on the Host Computer Before using the NI 9147 you must install the following application software and device drivers on the host computer in this order 1 LabVIEW 2014 SP1 or later 2 LabVIEW FPGA Modu...

Страница 5: ...dule with a slot and seat it in the slot until the latches lock in place Removing C Series Modules Verify that power is not connected to the I O connector s on the C Series module before you remove a...

Страница 6: ...or larger Screwdriver Phillips 2 What to Do Complete the following steps to ground the NI 9147 1 Attach the ring lug to the wire 2 Remove the grounding screw from the grounding terminal on the NI 914...

Страница 7: ...lists the POWER LED indicators Table 1 POWER LED Indicators LED Color LED Pattern Indication Green Solid The NI 9147 is powered on and the connected power supply is adequate Off The NI 9147 is powere...

Страница 8: ...teps to connect the NI 9147 to the host computer using the USB device port 1 Power on the host computer 2 Connect the NI 9147 to the host computer using the USB A to B cable Caution NI requires the us...

Страница 9: ...itoring prompts you to do so 2 Enter a unique name for your system in the Hostname field 3 Click the Security Configuration icon 4 Click Login 5 In the Login dialog box enter the username admin and le...

Страница 10: ...mat of 172 22 11 x 2 In MAX expand your system under Remote Systems 3 Select the Network Settings tab to configure the IP and other network settings 4 Optional Use the RJ 45 Ethernet port 1 to reconne...

Страница 11: ...k firewall or other security software by completing the following steps 1 On Windows 7 select Start Control Panel System and Security Windows Firewall Allow a program through Windows Firewall 2 Click...

Страница 12: ...safe mode or the NI 9147 is in install mode to indicate that software is currently being installed This pattern may also indicate that the user has forced the NI 9147 to boot into safe mode by pressin...

Страница 13: ...pplication Engineers Visit ni com services for NI Factory Installation Services repairs extended warranty and other services Visit ni com register to register your NI product Product registration faci...

Страница 14: ...nts txt file on your media or the National Instruments Patent Notice at ni com patents You can find information about end user license agreements EULAs and third party legal notices in the readme file...

Отзывы: