background image

Where to Go Next

APPLICATION

SUPPORT

NI Community

ni.com/community

NI CompactRIO
Developer’s Guide
ni.com/compactriodevguide

Software Support

ni.com/info    swsupport

Support

ni.com/support

SOFTWARE

CompactRIO Sample
Projects
LabVIEW   Create Project 

HARDWARE

NI 9147
Specifications
ni.com/manuals

NI 9147
User Manual
ni.com/manuals

C Series Getting
Started Guides
ni.com/manuals

Configuring a Project
NI-RIO Help 

Learn LabVIEW Basics
ni.com/gettingstarted

CompactRIO Examples
NI Example Finder

Services

ni.com/services

Worldwide Support and Services

The NI website is your complete resource for technical support. At 

ni.com/support

, you have

access to everything from troubleshooting and application development self-help resources to
email and phone assistance from NI Application Engineers.

Visit 

ni.com/services

 for NI Factory Installation Services, repairs, extended warranty, and

other services.

Visit 

ni.com/register

 to register your NI product. Product registration facilitates technical

support and ensures that you receive important information updates from NI.

A Declaration of Conformity (DoC) is our claim of compliance with the Council of the
European Communities using the manufacturer’s declaration of conformity. This system
affords the user protection for electromagnetic compatibility (EMC) and product safety. You
can obtain the DoC for your product by visiting 

ni.com/certification

. If your product supports

calibration, you can obtain the calibration certificate for your product at 

ni.com/calibration

.

NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas,
78759-3504. NI also has offices located around the world. For telephone support in the United

NI 9147 Getting Started Guide

  | 

© National Instruments

  | 

13

Содержание NI 9147

Страница 1: ...ines for Hazardous Locations The NI 9147 is suitable for use in Class I Division 2 Groups A B C D T4 hazardous locations Class I Zone 2 AEx nA IIC T4 and Ex nA IIC T4 hazardous locations and nonhazard...

Страница 2: ...Caution The system shall only be used in an area of not more than Pollution Degree 2 as defined in IEC 60664 1 Caution The system shall be mounted in an ATEX IECEx certified enclosure with a minimum i...

Страница 3: ...designing selecting and installing measurement probes and cables to ensure that the desired EMC performance is attained Preparing the Environment Ensure that the environment in which you are using th...

Страница 4: ...on the Host Computer Before using the NI 9147 you must install the following application software and device drivers on the host computer in this order 1 LabVIEW 2014 SP1 or later 2 LabVIEW FPGA Modu...

Страница 5: ...dule with a slot and seat it in the slot until the latches lock in place Removing C Series Modules Verify that power is not connected to the I O connector s on the C Series module before you remove a...

Страница 6: ...or larger Screwdriver Phillips 2 What to Do Complete the following steps to ground the NI 9147 1 Attach the ring lug to the wire 2 Remove the grounding screw from the grounding terminal on the NI 914...

Страница 7: ...lists the POWER LED indicators Table 1 POWER LED Indicators LED Color LED Pattern Indication Green Solid The NI 9147 is powered on and the connected power supply is adequate Off The NI 9147 is powere...

Страница 8: ...teps to connect the NI 9147 to the host computer using the USB device port 1 Power on the host computer 2 Connect the NI 9147 to the host computer using the USB A to B cable Caution NI requires the us...

Страница 9: ...itoring prompts you to do so 2 Enter a unique name for your system in the Hostname field 3 Click the Security Configuration icon 4 Click Login 5 In the Login dialog box enter the username admin and le...

Страница 10: ...mat of 172 22 11 x 2 In MAX expand your system under Remote Systems 3 Select the Network Settings tab to configure the IP and other network settings 4 Optional Use the RJ 45 Ethernet port 1 to reconne...

Страница 11: ...k firewall or other security software by completing the following steps 1 On Windows 7 select Start Control Panel System and Security Windows Firewall Allow a program through Windows Firewall 2 Click...

Страница 12: ...safe mode or the NI 9147 is in install mode to indicate that software is currently being installed This pattern may also indicate that the user has forced the NI 9147 to boot into safe mode by pressin...

Страница 13: ...pplication Engineers Visit ni com services for NI Factory Installation Services repairs extended warranty and other services Visit ni com register to register your NI product Product registration faci...

Страница 14: ...nts txt file on your media or the National Instruments Patent Notice at ni com patents You can find information about end user license agreements EULAs and third party legal notices in the readme file...

Отзывы: