![National Instruments MXIbus VME-AT2000 Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/national-instruments/mxibus-vme-at2000/mxibus-vme-at2000_getting-started_708997039.webp)
NI-VXI Software Installation and Configuration
Chapter 3
VME-AT2000/NI-VXI MS-DOS Getting Started
3-6
© National Instruments Corporation
Note:
INSTALL
will not create a backup for you. If there are files you want to
preserve, be sure to exit the installation program at this time and make a backup
before continuing.
You can quit the
INSTALL
program at any time by choosing Exit from the initial screen, or
by pressing <Control-C> once installation has begun.
INSTALL
will prompt you to be
certain you really want to quit at that time. If you choose to run the
INSTALL
program
again, it starts over and recopies all the necessary files. Of course, if you made any changes
from the default configuration, you will need to specify those changes once again.
As mentioned previously,
INSTALL
optionally modifies the
AUTOEXEC.BAT
file. If you
do modify it,
INSTALL
changes the old file's extension to
.BAK
and keeps it for safety
purposes. If you do not modify it,
INSTALL
creates a file in the NI-VXI directory with the
changes it proposes you make to the file, and names it
AUTOEXEC.VXI
.
Modifying the AUTOEXEC.BAT File
If you choose to let
INSTALL
modify your
AUTOEXEC.BAT
file, it updates the setting of
environment variables
PATH
,
LIB
, and
INCLUDE
to specify the relevant subdirectories of the
NI-VXI directory. The previously specified directories in
PATH
,
LIB
, and
INCLUDE
remain
unchanged.
INSTALL
also adds a new environment variable
NIVXIPATH
, and appends a
command line to execute
VXIINIT.EXE
automatically.
If you choose not to let
INSTALL
modify your
AUTOEXEC.BAT
file, refer to the
AUTOEXEC.VXI
file in your NI-VXI directory for suggestions on how to change the following
lines manually.
•
The
PATH
variable should include the full path to the subdirectory where the NI-VXI utilities
are located, in addition to whatever other directories you have already specified in
PATH
.
Normally, these files reside in the root of the NI-VXI directory.
•
The
LIB
variable should include the full path to the subdirectories that contain the C libraries
for the compiler you choose to install.
•
The
INCLUDE
variable should include the full path to the subdirectory that contains the
NI-VXI include files. By default, the include files reside in the
INCLUDE
subdirectory of
the NI-VXI directory.
•
The
NIVXIPATH
variable should contain the full path to the NI-VXI directory.
Notes:
After you execute
INSTALL
, you should reboot your machine (or at least run
AUTOEXEC.BAT
) to make your system aware of the NI-VXI directory.
Once the NI-VXI package is installed, run
VXIINIT.EXE
and then
RESMAN.EXE
.